background image

Warranty

Ten-Year Limited Cabinet Warranty

THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR:

- This Cabinet is warranted to be free from defects in material and

workmanship. The Filter Media is not included in this warrwnty. If Defect with the cabinet only appears within

Ten years from the date of original installation, whether or not actual use begins on that date, product is

warranted. If product installation criteria meets this standard, a new or remanufactured part, at the

manufacturer’s sole option, to replace any defective part will be provided without charge for the part itself;

PROVIDED the defective part is returned to the distributor through a qualified servicing dealer.

THIS WARRANTY DOES NOT INCLUDE LABOR OR OTHER COSTS - incurred for diagnosing, repairing,

removing, installing, shipping, servicing or handling of either defective parts or replacement parts. Such

costs may be covered by a separate warranty provided by the installer.

THIS WARRANTY APPLIES ONLY TO PRODUCTS IN THEIR ORIGINAL INSTALLATION LOCATION AND

BECOMES VOID UPON REINSTALLATION.

LIMITATIONS OF WARRANTIES – ALL IMPLIED WARRANTIES (INCLUDING IMPLIED WARRANTIES OF

FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY) ARE HEREBY LIMITED IN DURATION

TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN. SOME STATES DO NOT ALLOW

LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE MAY NOT APPLY TO YOU.

THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE

ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON

WHATSOEVER.

ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL

WORKING HOURS. ALL REPLACEMENT PARTS, WHETHER NEW OR REMANUFACTURED, ASSUME AS

THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY.

1. Normal maintenance as outlined in the installation and servicing instructions or owners manual including

filter cleaning and/or replacement and lubrication.

2. Damage or repairs required as a consequence of faulty installation, misapplication, abuse, improper

servicing, unauthorized alteration or improper operation.

3. Failure to start due to voltage conditions, blown fuses, open circuit breakers or other damages due to the

inadequacy or interruption of electrical service.

4. Damage as a result of floods, winds, fires, lightning, accidents, corrosive environments or other

conditions beyond the control of the Manufacturer.

5. Parts not supplied or designated by the Manufacturer, or damages resulting from their use.

6. Manufacturer products installed outside the continental U.S.A., Alaska, Hawaii, and Canada.

7. Electricity or fuel costs or increases in electricity or fuel costs from any reason whatsoever including

additional or unusual use of supplemental electric heat.

8. ANY SPECIAL INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANY

NATURE WHATSOEVER. Some states do not allow the exclusion of incidental or consequential

damages, so the above may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights which may vary from state

to state.

Part Number 155595-005 • 7/02                                                                                                                  Catalog No. 03EZ-CB0

Summary of Contents for EZXCAB-0016

Page 1: ...EZXCAB High Efficiency Air Filtration System Manual for Installation Operation Maintenance EZXCAB 0016 0020 Form Number EZCB 1SI IIEZCB 16 1 07 02 ...

Page 2: ...jury Understand the signal words DANGER WARNING and CAUTION These words are used with the safety alert symbol DANGER identifies the most serious hazards which result in severe personal injury or death WARNING signifies hazards which result in personal injury or death CAUTION is used to identify unsafe practices which result in minor personal injury or product and property damage The Model EZXCAB H...

Page 3: ...2 C02027 1 2 3 4 5 Figure 1 1 Cabinet Top 2 Filter Media 3 Access Handle 4 Access Door 5 Cabinet ...

Page 4: ...21 2 9 16 247 8 7 1 4 SPECIFICATIONS Dimensions Model Number Air Flow CFM Range 600 1600 600 2000 A 16 3 8 20 3 8 B 13 3 8 17 3 8 Replacement 3 12 months between changes Media Filter UL Class 2 EZXCAB 0016 EZXCAB 0020 ...

Page 5: ...4 Typical Pressure Drop EZXCAB 0016 EZXCAB 0020 Resistance In w c 600 04 03 800 07 04 1000 10 06 1200 14 08 1400 18 11 1600 23 13 1800 17 2000 18 Model Number Air Flow CFM AIR FLOW RESISTANCE ...

Page 6: ...etween the duct and the furnace move the return air drop SPACE SAVER HIGHBOY Installation beneath furnace Cleaner mounts horizontally where return air enters from below Raise furnace by installing a suitable wood structure and install air cleaner HORIZONTAL FURNACE Mounted vertically in return duct as close to the furnace as possible AIR FLOW MEDIA AIR CLEANER SHEET METAL TRANSITIONS AIR FLOW MEDI...

Page 7: ...air cleaner consider the application If a transition is required refer to section entitled The unit must be readily accessible for periodic inspection and replacement of media cartridge to maintain maximum efficiency and trouble free operation The air cleaner should be installed upstream of the cooling coil This will keep the coil clean and reduce air conditioning coil maintenance Improved cooling...

Page 8: ... the air cleaner Figure 3 Humidifiers Location of the system humidifier is important to the operation of the air cleaner When an evaporative type humidifier is used it may be installed between the furnace warm air duct and the return air duct without effecting the air cleaner Atomizing and spray type humidifiers should be installed upstream of the air cleaner ...

Page 9: ...et The directional arrows on the filter cartridge must point in the direction of air flow The air cleaner can be in any position except with the access door facing down The section entitled page 5 shows proper air cleaner mounting with a variety of furnace installations Prior to installing this product 1 Read rules and instructions carefully for safe operation Failure to follow them could damage t...

Page 10: ...gure 2 6 Mounting holes are provided for simple connection to duct work The 140 holes are sized for 8 sheet metal screws or 1 8 rivets If the adjoining duct work is flanged install the screws so that the screw heads are inside the cabinet This will prevent damage to the filter cartridge during removal and installation Figure 4 7 Remove media filter cartridge from plastic bag and replace media filt...

Page 11: ... 2 Pull used filter straight out of cabinet and disassemble and discard 3 Remove new filter cartridge from box and assemble 4 Slide new filter cartridge into cabinet with AIR FLOW arrow pointing in the direction of air flow 5 Replace door Remember periodic inspection and annual replacement of your filter will insure high efficiency air cleaning Contact your HVAC dealer for replacement filter cartr...

Page 12: ... MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTRIBUTOR DEALER OR OTHER PERSON WHATSOEVER ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY 1 Normal maintenance as outlined in the installation and servicing instructions or own...

Reviews: