![Carrier COMFORT 52C SERIES User Manual Download Page 30](http://html1.mh-extra.com/html/carrier/comfort-52c-series/comfort-52c-series_user-manual_2561166030.webp)
30
PERFORMANCE AND ELECTRICAL DATA
MODEL 52PQ (230/208-1-60)
LEGEND
EER —
Energy Efficiency Ratio
*Rated in accordance with ARI Standard 380-93.
†Coefficient of Performance (COP) at 47 F outdoor ambient
temperature.
**Electric resistance heater power and fan motor power.
††Fan motor indoor CFM (LO/HI) shown for 230-1-60 units.
RECEPTACLES AND FUSE TYPES
LEGEND
*May be used for 15-amp applications if fused for 15 amps.
MODEL
NUMBER
52PQ
CAPACITY* (Btuh)
HEATER
kW
EER
COP†
VOLTAGE
RANGE
(Volts)
AMPS
WATTS
Cooling
Heating
Cooling Heating**
Cooling
Heating
Rev. Cyc.
Electric
207---3
7,200/ 7,100
6,300/ 6,300
7,800/ 6,400
2.3
12.7/12.7 3.4/3.4
187-253
2.7/2.9
10.4/ 9.5
567/ 559 2393/1985
307---3
7,200/ 7,100
6,300/ 6,300 11,600/ 9,700
3.4
12.7/12.7 3.4/3.4
2.7/2.9
15.2/14.1
567/ 559 3493/2935
209---3
9,100/ 9,000
7,900/ 7,900
7,800/ 6,400
2.3
11.5/11.5 3.2/3.2
3.7/3.8
10.4/ 9.5
791/ 783 2393/1985
309---3
9,100/ 9,000
7,900/ 7,900 11,600/ 9,700
3.4
11.5/11.5 3.2/3.2
3.7/3.8
15.2/14.1
791/ 783 3493/2935
212---3
12,100/12,000 11,000/11,000
7,800/ 6,400
2.3
11.1/10.7 3.2/3.2
4.8/5.3
10.8/ 9.9 1090/1122 2470/2047
312---3
12,100/12,000 11,000/11,000 11,600/ 9,700
3.4
11.1/10.7 3.2/3.2
4.8/5.3
15.6/14.5 1090/1122 3570/2997
512---3
12,100/12,000 11,000/11,000 17,000/13,600
5.0
11.1/10.7 3.2/3.2
4.8/5.3
22.5/20.0 1090/1122 5170/4147
215---3
14,500/14,000 13,400/13,200
7,800/ 6,400
2.3
9.4/ 9.5 2.9/2.9
6.8/7.6
10.9/10.0 1543/1473 2517/2117
315---3
14,500/14,000 13,400/13,200 11,600/ 9,700
3.4
9.4/ 9.5 2.9/2.9
6.8/7.6
15.7/14.6 1543/1473 3617/3067
515---3
14,500/14,000 13,400/13,200 17,000/13,600
5.0
9.4/ 9.5 2.9/2.9
6.8/7.6
22.6/20.1 1543/1473 5217/4217
MODEL
NUMBER
52PQ
POWER
FACTOR
(%)
FAN MOTOR
MAX FUSE
SIZE
(Amps)
MIN.
CIRCUIT
AMPS
RECEP-
TACLE
TYPE
R-22
CHARGE
(oz)
DEHUMIDIFI-
CATION
(Pints/Hr)
SENSIBLE
HEAT
FACTOR
APPROX.
CHASSIS
SHIP WT.
(lb)
Watts
Full Load
Amps
Indoor CFM
LO/HI††
207---3
100
0.075
0.44
220/260
15
13.0
A
24
1.5
0.78
125
307---3
20
19.0
B
209---3
99
0.075
0.44
220/260
15
13.0
A
24
2.4
0.73
125
309---3
20
19.0
B
212---3
99
0.125
0.75
270/350
15
13.3
A
34
3.4
0.71
140
312---3
20
19.3
B
512---3
30
27.9
C
215---3
99
0.25
0.91
270/350
15
13.4
A
35
5.2
0.65
150
315---3
20
19.4
B
515---3
30
28.0
C
UNIT NAMEPLATE VOLTAGE
230/208
OUTLET RATED VOLTS/AMPS
250/15
250/20
250/30
OUTLET BLADE CONFIGURATION
A
B
C
NEMA CONFIGURATION
6-15R
6-20R
6-30R
TIME DELAY FUSE OR HACR
CIRCUIT BREAKER (AMPS)
15
20*
30
HEATER (KILOWATTS)
2.3
3.4
5.0
HACR —
Heating, Air Conditioning, and Refrigeration
NEMA —
National Electrical Manufacturers Association