Physical Data

Unit Size 

24040 

24060 

30040 

30060 

36060 

42060 

42090 

48090 

60090 

NOMINAL CAPACITY (ton) 

2-1/2 

2-1/2 

3-1/2 

3-1/2 

SHIPPING WEIGHT lb.

SHIPPING WEIGHT (kg)

329

149

329

149

361

164

361

164

390

177

455

206

455

206

480

218

497

225

COMPRESSOR / QUANTITY

Rotary / 1

Scroll / 1

REFRIGERANT (R-410A)

Quantity lb.

Quantity (kg) 

5.3

2.4

5.3

2.4

6.0

2.7

6.0

2.72

8.2

3.7

6.2

2.8

6.2

2.8

9.2

4.2

9.8

4.4

REFRIGERANT METERING DEVICE 

Orifice

Orifice

TXV

Orifice

ORIFICE ID in. / mm

.059 / 1.5

.059 / 1.5

.063 / 1.60

.061 / 1.55

N/A

.073 / 1.85

.080 / 2.03

.084 / 2.14

OUTDOOR COIL 

Rows...Fins/in.

Face Area (sq ft) 

1..21

11.9

1...21

11.9

1...21

13.6 

1...21

13.6

1...21

18.8

1...21

13.6

1...21

13.6

1...21

21.4

1...21

23.3

OUTDOOR FAN

Nominal CFM

Diameter in.

Diameter (mm)

Motor Hp (Rpm) 

2500

24

609.6

1/10 (810) 

2500

24

609.6

1/10 (810) 

2700

24

609.6

1/10 (810) 

2700

24

609.6

1/10 (810)

3200

24

609.6

1/5 (810)

3600

26

660.4

1/5 (810

3600

26

660.4

1/5 (810)

3600

26

660.4

1/5 (810)

4200

26

660.4

1/5 (810)

INDOOR COIL

Rows...Fins/in.

Face Area (sq ft) 

3...17

3.7 

3...17

3.7 

3...17

3.7 

3...17

3.7 

3...17

3.7 

3...17

4.7 

3...17

4.7 

3...17

4.7

3...17

5.6

INDOOR BLOWER

Nominal Cooling Airflow (Cfm)

Size in.

Size (mm.)

Motor HP (RPM)

800

10x10

254x254

1/2 (1050)

800

10x10

254x254

1/2 (1050)

1000

10x10

254x254

1/2 (1050)

1000

10x10

254x254

1/2 (1050)

1150

11x10

279.4x254

3/4 (1000)

1350

11x10

279.4x254

1/2 (1050)

1350

11x10

279.4x254

1/2 (1050)

1550

11x10

279.4x254

1.0 (1075)

1750

11x10

279.4x254

1.0 (1040)

FURNACE SECTION 

*

Burner Orifice No. (Qty...Drill Size)

1 & 3 Phase Ultra Low NOx- Natural Gas 

(Factory Installed)

*. Based on altitude of 0 to 2000 ft (0-610m)

1...0.125” size

1…#28

1...0.125” size

1…#28

1…#28

1…#28

1...#18

1...#18

1...#18

HIGH-PRESSURE SWITCH

(psig) Cut-out Reset (Auto) 

650 +/- 15

420 +/- 25

650 +/- 15

420 +/- 25

LOSS-OF-CHARGE / LOW-PRESSURE 

SWITCH (Liquid Line) (psig) cut-out Reset 

(auto)

50 +/- 7

95 +/- 7

20 +/- 5

45 +/- 10

N/A

RETURN-AIR FILTERS

 

Throwaway Size in

(mm)

†. Required filter sizes shown are based on the larger of the AHRI (Air Conditioning Heating and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of 300 to 350 ft/minute for throwaway type. Air 

filter pressure drop for non-standard filters must not exceed 0.08 IN. W.C. 

If using accessory filter rack refer to the filter rack installation instructions for correct filter sizes and quantity. 

N/A= Not Available

2 each 20x12x1

508x305x25

2 each 20x12x1

508x305x25

1 each 24x14x1

610x356x25

24x15x1

610x406x25

1 each 24x16x1 (in.)

610x406x25 (mm)

24x18x1 (in.)

610x457x25 (mm)

Summary of Contents for Comfort 48VLU-E

Page 1: ...to allow vertical ductwork connections The basepan seals on the bottom openings to ensure a positive seal cin the vertical airflow mode Efficient operation high efficiency design offers SEER Seasonal...

Page 2: ...d horizontal metal duct covers with insulation come with the unit and cover the horizontal duct openings These can be left in place if the units are converted to downflow Integrated Gas Control IGC bo...

Page 3: ...cal Supply 3 208 230 1 60 5 208 230 3 60 Options GP Base unit with tin plated indoor coil hairpins and stainless steel HX TP Base unit with tin plated indoor coil hairpins Single Phase Only Major Seri...

Page 4: ...eflecting the effects of circulating fan heat Ratings are based on Cooling Standard 80 F 26 7 C db 67 F wb 19 4 C indoor entering air temperature and 95 F db 35 C outdoor entering air temperature 2 Be...

Page 5: ...IZER COIL FILTER SIDE VIEW CAULK BOTTOM CORNER OF ECONOMIZER ON EACH SIDE BASE COIL FLANGE ON BASE DETAIL ECONOMIZER FI LTER EV APORATOR COIL TOP FILTER RACK BEND FLANGE AT 90 SCREW TO DIVIDER WITH 1...

Page 6: ...17 3 7 3 17 4 7 3 17 4 7 3 17 4 7 3 17 5 6 INDOOR BLOWER Nominal Cooling Airflow Cfm Size in Size mm Motor HP RPM 800 10x10 254x254 1 2 1050 800 10x10 254x254 1 2 1050 1000 10x10 254x254 1 2 1050 100...

Page 7: ...48VLU E 48VLU F Ultra Low NOx Product Data Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 7 Unit Dimensions 24 36 A200161...

Page 8: ...48VLU E 48VLU F Ultra Low NOx Product Data Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 8 Unit Dimensions 42 60 A200157...

Page 9: ...as required to unit being installed 3 Roof curb is made of 16 gauge steel 4 Attach ductwork to curb flanges of duct rest on curb 5 Insulated panels 1 in 25 4 mm thick fiberglass 1 lb density Accessor...

Page 10: ...00 Btuh and a SHC of 27 400 Btuh Calculate SHC correction if required using Note 4 under Cooling Capacities tables SELECT HEATING CAPACITY OF UNIT TO PROVIDE DESIGN CONDITION REQUIREMENT In the Heatin...

Page 11: ...70 1 55 27 20 13 77 1 76 24 84 12 86 1 99 22 48 11 95 2 24 19 68 10 89 2 51 17 14 9 92 2 77 800 57 13 8 24 74 24 74 1 57 22 92 22 92 1 77 21 02 21 02 1 99 18 78 18 78 2 19 16 65 16 65 2 42 14 70 14 7...

Page 12: ...23 74 19 09 3 02 71 21 7 33 22 18 60 2 02 31 86 18 10 2 24 30 33 17 53 2 48 28 62 16 90 2 76 26 55 16 13 3 08 1000 57 13 9 28 61 28 61 2 01 27 47 27 47 2 22 26 20 26 20 2 47 24 68 24 68 2 75 22 66 22...

Page 13: ...95 2 46 40 11 20 71 2 72 37 12 19 45 3 00 34 07 18 16 3 32 30 95 16 85 3 69 27 81 15 51 4 11 1150 57 13 8 36 19 36 19 2 46 33 98 33 98 2 71 31 67 31 67 3 00 29 30 29 30 3 32 26 84 26 84 3 70 24 34 24...

Page 14: ...17 2 66 45 92 23 18 3 05 43 20 22 16 3 52 40 37 21 10 4 06 37 44 20 00 4 70 34 27 18 84 5 44 1350 57 13 8 40 50 40 50 2 58 38 39 38 39 2 95 36 24 36 24 3 40 34 01 34 01 3 92 31 54 31 54 4 51 28 67 28...

Page 15: ...79 3 18 53 50 27 36 3 56 49 89 25 89 3 99 46 16 24 36 4 48 42 23 22 80 5 04 37 37 21 00 5 64 1550 57 13 8 47 02 47 02 3 17 44 27 44 27 3 54 41 50 41 50 3 96 38 53 38 53 4 44 34 79 34 79 4 92 30 91 30...

Page 16: ...58 3 78 66 06 32 25 4 31 61 55 30 87 4 93 56 94 29 39 5 64 52 21 27 88 6 45 47 19 26 29 7 37 2000 57 13 8 59 44 59 44 3 78 55 93 55 93 4 31 52 41 52 41 4 92 48 83 48 83 5 62 44 92 44 92 6 44 39 97 39...

Page 17: ...System KW is total of indoor and outdoor unit kilowatts LEGEND BF Bypass Factor edb Entering Dry Bulb Ewb Entering Wet Bulb kW Total Unit Power Input SHC Sensible Heat Capacity 1000 Btuh TC Total Cap...

Page 18: ...m use U S A column 2001 to 3000 ft 611 to 914 m 0 to 2000 0 610 m 45 000 Orifice No Qty 0 125 in Manifold Press in W C 3 2 3 8 60 000 Orifice No Qty 28 1 Manifold Press in W C 3 2 3 8 89 000 Orifice...

Page 19: ...lternate Heating CFM 840 759 677 600 505 411 293 x x x BHP 0 14 0 15 0 16 0 16 0 17 0 17 0 18 x x x Gas Heat Rise F 53 NA NA NA NA NA NA NA NA NA Gas Heat Rise C 30 NA NA NA NA NA NA NA NA NA Medium R...

Page 20: ...6 1151 1115 1075 1039 1001 957 914 870 BHP 0 34 0 34 0 35 0 36 0 37 0 37 0 38 0 39 0 40 0 41 Gas Heat Rise F 37 38 39 40 42 43 45 47 49 52 Gas Heat Rise oC 20 21 22 22 23 24 25 26 27 29 Med High Orang...

Page 21: ...1264 1213 1159 BHP 0 40 0 42 0 43 0 44 0 45 0 46 0 47 0 48 0 49 0 50 48090 35 65 19 36 Low Blue CFM 644 552 461 376 301 235 x x x x BHP 0 06 0 07 0 07 0 08 0 08 0 09 x x x x Gas Heat Rise F NA NA NA...

Page 22: ...5 0 66 0 67 0 69 0 70 0 71 0 73 Gas Heat Rise F NA NA NA NA NA NA NA NA NA NA Gas Heat Rise C NA NA NA NA NA NA NA NA NA NA High Black High Static Cooling Only CFM 2271 2241 2206 2171 2134 2080 1973 1...

Page 23: ...1800 CFM 16x24x1 14x24x1 406x610x25 356x610x25 3 5 4 0 0 10 0 11 0 12 0 13 0 14 0 16 0 16 1500 2200 CFM 16x24x1 18x24x1 406x610x25 457x610x25 5 0 0 15 0 17 0 18 0 20 0 21 0 22 0 23 0 23 Filter Pressur...

Page 24: ...tion do not require duct covers Airflow Units are draw thru in the cooling mode and blow thru in the heating mode Maximum cooling airflow To minimize the possibility of condensate blow off from the ev...

Page 25: ...7 79 1 05 5 8 0 70 27 8 40 3606050 208 230 3 60 197 253 10 4 73 1 05 5 8 0 70 19 9 30 4206030 208 230 1 60 197 253 16 7 109 1 07 3 8 0 70 25 8 40 4206050 208 230 3 60 197 253 11 2 88 1 05 3 8 0 70 18...

Page 26: ...48VLU F Ultra Low NOx Product Data Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 26 Connection Wiring Schematic 208 230 1 60...

Page 27: ...E 48VLU F Ultra Low NOx Product Data Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 27 Ladder Wiring Schematic 208 230 1 60 A2...

Page 28: ...48VLU F Ultra Low NOx Product Data Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 28 Connection Wiring Schematic 208 230 3 60...

Page 29: ...E 48VLU F Ultra Low NOx Product Data Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 29 Ladder Wiring Schematic 208 230 3 60 A2...

Page 30: ...satisfied and W is de energized the pre mix burner will stop firing and the indoor evaporator fan motor shuts off after a 90 second time off delay Please note that the IGC has the capability to automa...

Page 31: ...ate trap Fans The evaporator fan shall be a multi speed direct drive as shown on equipment drawings Fan wheel shall be made from steel be double inlet type with forward curved blades with corrosion re...

Page 32: ...on power failure 6 Filter Rack Kit Shall provide filter mounting for downflow applications Offered as a field installed accessory 7 Flat Roof Curb Curbs shall have seal strip and a wood nailer for fla...

Reviews: