11—Unit

Wiring

Diagram

A92176

FU1

IDR

PL1-3

PR-1

PR-2

SEC-1

SEC-2

TRAN

24VAC

115VAC

BLWM

LO

MED LO

MED HI

HI

COM

CAP

L2

COM

4

3

2

1

C

CFR

HFR

PL4

NOTE#4

NOTE#8

EAC-1

EAC-2

L1

ILK

EQUIPMENT GROUND

TO 115V AC FIELD DISCONNECTIONS

NOTE #5

NOTE#10

PL2

L1

L2

PL1-1

IDR

PL1-4

ALS

FL

LS

PL1-7

R

Y

W

G

C

NOTE #1

CFR

NOTE #10

PL1-2

PL1-6

NC

NO

PRS

C

DSS

TH

TR

PILOT

MGV

GV

PL1-8

TIME

DELAY

LOGIC

HFR

3A

FUSE

PL1-9

(WHEN USED)

NOTE #7

SCHEMATIC

DIAGRAM

MGV

1

4

7

2

5

8

3

6

9

BLWM

MED LO

MED HI

HI

COM

LO

CAP

PRS

C

NO

NC

DSS

BRN

TH

PILOT

GV

TR

ALS

(WHEN USED)

NOTE #7

FL

LS

ORN

YEL

BRN

BLU

RED

BLK

RED

BLU

BLK

BLK

BLU

RED

WHT

TRAN

WHT

ILK

NOTE #5

WHT

BLK

IDM

GRN

JB

GRN

BLK

WHT

FU2

FUSED DISCONNECT

SWITCH (WHEN REQ'D)

BRN

BRN

WHT

BLK

RED

WHT

BLK

COM

PR2

L2

L1

PR1

HFR

CFR

LO

HI

NOTE #10

EAC-1

EAC-2

W

Y

R

C

G

NOTE #9

PCB

NOTE #1

GROUND

SCREW

REQ'D

FU1

3AMP

FUSE

NOTE #8

SEC-1

SEC-2

IDR

PL1

CONNECTION

DIAGRAM

JUNCTION

TERMINAL

PCB TERMINAL

FACTORY POWER WIRING (120VAC)

FACTORY CONTROL WIRING (120VAC)

FIELD POWER WIRING (120VAC)

CONDUCTOR ON PCB

FIELD WIRING SCREW TERMINAL

FIELD GROUND

EQUIPMENT GROUND

FIELD SPLICE

PLUG RECEPTACLE

AUX. LIMIT SWITCH (OVER TEMP), SPST-(N.C.),

MANUAL RESET

BLOWER MOTOR

CAPACITOR

COOLING FAN RELAY, SPDT

DRAFT SAFEGUARD SWITCH, SPST-(N.C.), MANUAL RESET

ELECTRONIC AIR CLEANER CONNECTION (115VAC)

ELECTRONIC AIR CLEANER CONNECTION (COMMON)

FUSE, 3 AMP, AUTOMOTIVE BLADE TYPE

FUSE, FIELD INSTALLED

FUSIBLE LINK

GAS VALVE, (REDUNDANT)

HEATING FAN RELAY, SPST (N.O.)

INDUCED DRAFT MOTOR

INDUCER DRAFT RELAY, DPST-(N.O.)

BLOWER DOOR INTERLOCK SWITCH, SPST-(N.O.)

JUNCTION BOX

LIMIT SWITCH (OVER TEMP), SPST-(N.C.), AUTO RESET

PRINTED CIRCUIT BOARD (FURNACE CONTROL)

9-CIRCUIT CONNECTOR (PCB1)

2-CIRCUIT CONNECTOR (L1, L2)

5-CIRCUIT PLUG CONNECTOR (BLWM)

PRESSURE SWITCH, SPDT

TRANSFORMER (115VAC/24VAC)

ALS

BLWM

CAP

CFR

DSS

EAC-1

EAC-2

FU1

FU2

FL

GV

HFR

IDM

IDR

ILK

JB

LS

PCB

PL1

PL2

PL4

PRS

TRAN

LEGEND

NOTES:

  1.  INTERNALLY CONNECTED TO EQUIPMENT GROUND THROUGH MOUNTING SCREW.

  2.  IF ANY OF THE ORIGINAL EQUIPMENT WIRE IS REPLACED, USE WIRE RATED FOR

       105° C.

  3.  BLOWER MOTOR (BLWM) & INDUCER MOTOR (IDM) CONTAIN AUTO-RESET

       THERMAL OVERLOAD SWITCH.

  4.  BLOWER MOTOR FACTORY SPEED SELECTIONS (PL4) ARE FOR AVERAGE

       CONDITIONS. SEE INSTALLATION INSTRUCTIONS FOR DETAILS ON OPTIMUM

       SPEED SELECTIONS.

  5.  USE ONLY COPPER WIRE BETWEEN THE DISCONNECT SWITCH AND THE

       FURNACE JUNCTION BOX (JB).

  6.  SYMBOLS ARE ELECTRICAL REPRESENTATIONS ONLY.

  7.  AUXILIARY LIMIT SWITCH (ALS) USED ON DOWNFLOW MODELS ONLY.

  8.  THE TRANSFORMER 24VAC WINDING IS PROTECTED BY A 3 AMP AUTOMOTIVE

       BLADE TYPE FUSE ON THE CONTROL BOARD. A 24VAC SHORT TO GROUND

       DURING INSTALLATION, CHECKOUT, OPERATION, SERVICE OR MAINTENANCE

       COULD CAUSE THIS FUSE TO OPEN. DO NOT REPLACE THE 3 AMP FUSE

       WITH ANY OTHER SIZE FUSE.

  9.  BLOWER MOTOR (BLWM) ADJUSTABLE OFF-DELAY. FACTORY SET:  120 SECS.

       CUT RESISTOR:  180 SECS.

10.  WHEN CFR RELAY IS ENERGIZED, HFR RELAY IS ALSO ENERGIZED.

319593-401 REV. C

RED 
WHT

4

3

2

1

C

PL2

1

2

NOTE #4

PL4

IDM

IDR

9

Summary of Contents for 58DFA

Page 1: ...lation Codes NSCNGPIC Wear safety glasses and work gloves Have fire extinguisher available during start up and adjustment procedures and service calls Understand the signal word DANGER WARNING or CAU TION These words are used with the safety alert symbol DAN GER identifies the most serious hazards which will result in severe personal injury or death WARNING signifies hazards that could result in p...

Page 2: ... further information the National Fuel Gas Code is available from National Fire Protection Association Inc Battery march Park Quincy MA 02269 American Gas Association 1515 Wilson Boulevard Arlington VA 22209 or from Literature Distribution Table 2 Dimensions In UNIT SIZE A D E VENT CONN SHIP WT 071 08 14 3 16 12 9 16 12 11 16 4 135 071 12 14 3 16 12 9 16 12 11 16 4 139 091 12 17 1 2 15 7 8 16 4 14...

Page 3: ... are manually operated they must be equipped with means to prevent operation of either unit unless the damper is in the full heat or full cool position HAZARDOUS LOCATIONS When the furnace is installed in a residential garage it must be installed so that the burners and ignition source are located at least 18 in above the floor The furnace should be protected from physical damage by vehicles When ...

Page 4: ... for all equipment within the confined space but not less than 100 sq in per opening See Fig 2 For Example 58DFA FURNACE IN PUT BTUH FREE AREA PER OPENING SQ IN 66 000 100 88 000 100 110 000 110 132 000 132 If the building is constructed unusually tight a permanent opening directly communicating with the outdoors should be provided This opening should have a minimum free area of 1 sq in per 5000 B...

Page 5: ... ON A CONCRETE SLAB 1 Construct hole in floor per dimensions in Fig 4 and Table 3 2 Install plenum and furnace as shown in Fig 5 INSTALLATION ON A COMBUSTIBLE FLOOR 1 Cut and frame hole in floor per dimensions in Installation Instructions packaged with downflow subbase 2 When completed downflow subbase plenum and furnace or coil casing when used should be installed as shown in Fig 6 Fig 4 Floor Op...

Page 6: ...has been attached If the pressure exceeds 0 5 psig 14 in wc the gas supply pipe must be disconnected from the furnace and capped before the pressure test If the test pressure is equal to or less than 0 5 psig 14 in wc close the manual shut off valve located on the gas valve before the test It is recommended that the ground joint union be loosened before pressure testing Never purge a line into a c...

Page 7: ...ment after installation Step 8 Start up Adjustment and Safety Check GENERAL The furnace must have a 115 v power supply properly connected and grounded Thermostat wire connections at R W C and Y must be made at the 24 v terminal block on the control board The gas service pressure must not exceed 0 5 psig 14 in wc but must be no less than 0 16 psig 4 5 in wc Before operating the furnace check each m...

Page 8: ... gas valve GV Gas flow to the pilot and main burners stops until the pilot is manually relit NOTE When gas valve GV is energized R W circuit is closed After a power interruption the gas valve closes within 7 sec and the furnace skips the blower on delay and immediately starts the blower 2 Cooling mode When the thermostat calls for cooling R G and Y circuits close Simultaneously the R Y circuit sta...

Page 9: ...TIVE BLADE TYPE FUSE FIELD INSTALLED FUSIBLE LINK GAS VALVE REDUNDANT HEATING FAN RELAY SPST N O INDUCED DRAFT MOTOR INDUCER DRAFT RELAY DPST N O BLOWER DOOR INTERLOCK SWITCH SPST N O JUNCTION BOX LIMIT SWITCH OVER TEMP SPST N C AUTO RESET PRINTED CIRCUIT BOARD FURNACE CONTROL 9 CIRCUIT CONNECTOR PCB1 2 CIRCUIT CONNECTOR L1 L2 5 CIRCUIT PLUG CONNECTOR BLWM PRESSURE SWITCH SPDT TRANSFORMER 115VAC 2...

Page 10: ...wc for natural gas When adjusting input rate do not set manifold pressure above 3 8 in wc or below 3 2 in wc a Check gas input rate using Table 6 1 Obtain average yearly heat value for local gas supply 1 Obtain average yearly specific gravity for local gas supply 1 Verify furnace model Table 6 can only be used for model 58DFA Furnaces 1 Check and verify orifice size in furnace NEVER ASSUME THE ORI...

Page 11: ...3 4 3 6 38 39 40 3 2 3 5 3 7 38 39 40 3 3 3 6 3 8 875 42 3 4 41 42 3 2 3 6 41 42 3 3 3 7 41 42 40 3 4 3 8 3 2 41 40 3 5 3 3 41 39 40 3 6 3 2 3 4 41 39 40 3 8 3 3 3 5 39 40 3 3 3 6 38 39 40 3 2 3 4 3 7 890 42 3 3 42 3 4 41 42 3 2 3 6 41 42 3 3 3 7 41 42 3 4 3 8 41 40 3 5 3 2 41 40 3 6 3 3 41 39 40 3 7 3 2 3 4 41 39 40 3 8 3 3 3 5 905 42 3 2 42 3 3 42 3 4 41 42 3 2 3 6 41 42 3 3 3 7 41 42 3 4 3 8 41...

Page 12: ...s per hr CHECK SAFETY CONTROLS 1 Check operation of gas shut off control for 100 percent shutoff NOTE The furnace pilot must be lit so the thermocouple energizes the thermal magnet circuit of gas valve GV which permits gas flow to the remaining portion of the valve If the pilot flame is extinguished the thermocouple will no longer energize the thermal magnet circuit of the gas valve Gas flow to th...

Page 13: ...n off 115 v power to furnace b Remove control door and disconnect inducer motor lead wires from wire harness c Turn on 115 v power to furnace d Close thermostat switch as if making normal furnace start If the burners do not light the pressure switch is function ing properly e Turn off 115 v power to furnace f Reconnect inducer motor wires replace control door and turn on 115 v power 5 Check auxili...

Page 14: ...46231 35006c Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice and without incurring obligations Book 1 4 Tab 6a 8a PC 101 Catalog No 565 812 Printed in U S A Form 58DF 9SI Pg 14 11 93 Replaces 58DF 6SI ...

Reviews: