This furnace must be installed in the downflow configuration
ONLY. Improper installation, adjustment, alteration, service,
maintenance, or use can cause carbon monoxide poisoning,
explosion, fire, electrical shock, or other conditions which
may cause personal injury, loss of life, or property damage.
Consult a qualified installer, service agency, local gas sup-
plier, or your distributor or branch for information or assis-
tance. The qualified installer or agency must use only
factory-authorized and listed kits or accessories when modi-
fying this product. Failure to follow this warning could result
in electrical shock, fire, personal injury, or death.

The design of the downflow gas-fired furnace is A.G.A./C.G.A.
certified for natural and propane gas and for installation on
noncombustible flooring. The furnace may be installed on com-
bustible flooring when installed with the accessory downflow
subbase. This furnace is for installation in alcoves, attics, base-
ments, closets, or utility rooms. The design of this furnace line is
not A.G.A./C.G.A. certified for installation in mobile homes,
recreation vehicles, or outdoors.
Before installing the furnace, refer to the current edition of the
National NFGC. Canadian installations must be installed in
accordance with NSCNGPIC and all authorities having jurisdic-
tion. For further information, the National Fuel Gas Code is
available from National Fire Protection Association Inc., Battery-
march Park, Quincy, MA 02269, American Gas Association, 1515
Wilson Boulevard, Arlington, VA 22209, or from Literature
Distribution.

Table 2—Dimensions (In.)

UNIT SIZE

A

D

E

VENT CONN SHIP. WT

071-08

14-3/16 12-9/16 12-11/16

4

135

071-12

14-3/16 12-9/16 12-11/16

4

139

091-12

17-1/2

15-7/8

16

4

146

091-16

17-1/2

15-7/8

16

4

146

110-16

17-1/2

15-7/8

16

4

163

110-20

21

19-3/8

19-1/2

4

171

135-20

24-1/2

22-7/8

23

5

182

Application of this furnace should be indoors with special
attention given to vent sizing and material, gas input rate, air
temperature rise, and unit sizing. Improper installation or
misapplication of the furnace can require excessive servicing
or cause premature component failure.

Reference should also be made to the regulations of the serving gas
supplier and the local building, heating, plumbing, or other codes
in effect in the area in which the installation is made. In the
absence of local codes, the installation must conform with the
NFGC.

This furnace is designed for a minimum continuous return-air
temperature of 60°F db or intermittent operation down to 55° F db
such as when used with a night setback thermostat. Return-air
temperature must not exceed a maximum of 85° F db.

For accessory installation details, refer to the applicable installa-
tion literature.

NOTE:

Remove all shipping brackets and materials before oper-

ating the furnace.

Fig. 1—Dimensional Drawing

A88324

2

Summary of Contents for 58DFA

Page 1: ...lation Codes NSCNGPIC Wear safety glasses and work gloves Have fire extinguisher available during start up and adjustment procedures and service calls Understand the signal word DANGER WARNING or CAU TION These words are used with the safety alert symbol DAN GER identifies the most serious hazards which will result in severe personal injury or death WARNING signifies hazards that could result in p...

Page 2: ... further information the National Fuel Gas Code is available from National Fire Protection Association Inc Battery march Park Quincy MA 02269 American Gas Association 1515 Wilson Boulevard Arlington VA 22209 or from Literature Distribution Table 2 Dimensions In UNIT SIZE A D E VENT CONN SHIP WT 071 08 14 3 16 12 9 16 12 11 16 4 135 071 12 14 3 16 12 9 16 12 11 16 4 139 091 12 17 1 2 15 7 8 16 4 14...

Page 3: ... are manually operated they must be equipped with means to prevent operation of either unit unless the damper is in the full heat or full cool position HAZARDOUS LOCATIONS When the furnace is installed in a residential garage it must be installed so that the burners and ignition source are located at least 18 in above the floor The furnace should be protected from physical damage by vehicles When ...

Page 4: ... for all equipment within the confined space but not less than 100 sq in per opening See Fig 2 For Example 58DFA FURNACE IN PUT BTUH FREE AREA PER OPENING SQ IN 66 000 100 88 000 100 110 000 110 132 000 132 If the building is constructed unusually tight a permanent opening directly communicating with the outdoors should be provided This opening should have a minimum free area of 1 sq in per 5000 B...

Page 5: ... ON A CONCRETE SLAB 1 Construct hole in floor per dimensions in Fig 4 and Table 3 2 Install plenum and furnace as shown in Fig 5 INSTALLATION ON A COMBUSTIBLE FLOOR 1 Cut and frame hole in floor per dimensions in Installation Instructions packaged with downflow subbase 2 When completed downflow subbase plenum and furnace or coil casing when used should be installed as shown in Fig 6 Fig 4 Floor Op...

Page 6: ...has been attached If the pressure exceeds 0 5 psig 14 in wc the gas supply pipe must be disconnected from the furnace and capped before the pressure test If the test pressure is equal to or less than 0 5 psig 14 in wc close the manual shut off valve located on the gas valve before the test It is recommended that the ground joint union be loosened before pressure testing Never purge a line into a c...

Page 7: ...ment after installation Step 8 Start up Adjustment and Safety Check GENERAL The furnace must have a 115 v power supply properly connected and grounded Thermostat wire connections at R W C and Y must be made at the 24 v terminal block on the control board The gas service pressure must not exceed 0 5 psig 14 in wc but must be no less than 0 16 psig 4 5 in wc Before operating the furnace check each m...

Page 8: ... gas valve GV Gas flow to the pilot and main burners stops until the pilot is manually relit NOTE When gas valve GV is energized R W circuit is closed After a power interruption the gas valve closes within 7 sec and the furnace skips the blower on delay and immediately starts the blower 2 Cooling mode When the thermostat calls for cooling R G and Y circuits close Simultaneously the R Y circuit sta...

Page 9: ...TIVE BLADE TYPE FUSE FIELD INSTALLED FUSIBLE LINK GAS VALVE REDUNDANT HEATING FAN RELAY SPST N O INDUCED DRAFT MOTOR INDUCER DRAFT RELAY DPST N O BLOWER DOOR INTERLOCK SWITCH SPST N O JUNCTION BOX LIMIT SWITCH OVER TEMP SPST N C AUTO RESET PRINTED CIRCUIT BOARD FURNACE CONTROL 9 CIRCUIT CONNECTOR PCB1 2 CIRCUIT CONNECTOR L1 L2 5 CIRCUIT PLUG CONNECTOR BLWM PRESSURE SWITCH SPDT TRANSFORMER 115VAC 2...

Page 10: ...wc for natural gas When adjusting input rate do not set manifold pressure above 3 8 in wc or below 3 2 in wc a Check gas input rate using Table 6 1 Obtain average yearly heat value for local gas supply 1 Obtain average yearly specific gravity for local gas supply 1 Verify furnace model Table 6 can only be used for model 58DFA Furnaces 1 Check and verify orifice size in furnace NEVER ASSUME THE ORI...

Page 11: ...3 4 3 6 38 39 40 3 2 3 5 3 7 38 39 40 3 3 3 6 3 8 875 42 3 4 41 42 3 2 3 6 41 42 3 3 3 7 41 42 40 3 4 3 8 3 2 41 40 3 5 3 3 41 39 40 3 6 3 2 3 4 41 39 40 3 8 3 3 3 5 39 40 3 3 3 6 38 39 40 3 2 3 4 3 7 890 42 3 3 42 3 4 41 42 3 2 3 6 41 42 3 3 3 7 41 42 3 4 3 8 41 40 3 5 3 2 41 40 3 6 3 3 41 39 40 3 7 3 2 3 4 41 39 40 3 8 3 3 3 5 905 42 3 2 42 3 3 42 3 4 41 42 3 2 3 6 41 42 3 3 3 7 41 42 3 4 3 8 41...

Page 12: ...s per hr CHECK SAFETY CONTROLS 1 Check operation of gas shut off control for 100 percent shutoff NOTE The furnace pilot must be lit so the thermocouple energizes the thermal magnet circuit of gas valve GV which permits gas flow to the remaining portion of the valve If the pilot flame is extinguished the thermocouple will no longer energize the thermal magnet circuit of the gas valve Gas flow to th...

Page 13: ...n off 115 v power to furnace b Remove control door and disconnect inducer motor lead wires from wire harness c Turn on 115 v power to furnace d Close thermostat switch as if making normal furnace start If the burners do not light the pressure switch is function ing properly e Turn off 115 v power to furnace f Reconnect inducer motor wires replace control door and turn on 115 v power 5 Check auxili...

Page 14: ...46231 35006c Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice and without incurring obligations Book 1 4 Tab 6a 8a PC 101 Catalog No 565 812 Printed in U S A Form 58DF 9SI Pg 14 11 93 Replaces 58DF 6SI ...

Reviews: