background image

1

50SD

Legacy

t

Single--Packaged Air Conditioner System

With R--22 Refrigerant

Single-- and Three--Phase Units Sizes 024--060

Installation Instructions

NOTE

: Read the entire instruction manual before starting the

installation.

NOTE

: Installer: Make sure the Owner’s Manual and Service

Instructions are left with the unit after installation.

TABLE OF CONTENTS

Page

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

RECEIVING AND INSTALLATION

2--9

. . . . . . . . . . . . . . . . .

Check Equipment

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Identify Unit

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Inspect Shipment

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Provide Unit Support

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Roof Curb

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Slab Mount

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Ground Mount

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Provide Clearances

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Field Fabricate Ductwork

2

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Rig and Place Unit

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Inspection

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Use of Rigging Bracket

6

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Connect Condensate Drain

7

. . . . . . . . . . . . . . . . . . . . . . . . . .

Install Duct Connections

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Configuring Units for Downflow (Vertical) Discharge

7

. . . . .

Install Electrical Connections

8

. . . . . . . . . . . . . . . . . . . . . . . .

High--Voltage Connections

9

. . . . . . . . . . . . . . . . . . . . . . . .

Special Procedures for 208v Operation

9

. . . . . . . . . . . . . . .

Control Voltage Connections

9

. . . . . . . . . . . . . . . . . . . . . . .

Standard Connection

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Transformer Protection

9

. . . . . . . . . . . . . . . . . . . . . . . . . . .

PRE--START--UP

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

START--UP

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Check for Refrigerant Leaks

10

. . . . . . . . . . . . . . . . . . . . . . . .

Start--Up Adjustments

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Checking Cooling Control Operation

12

. . . . . . . . . . . . . . .

Checking and Adjusting Refrigerant Charge

12

. . . . . . . . . .

Indoor Airflow and Airflow Adjustments

17

. . . . . . . . . . . .

Cooling Sequence of Operation

17

. . . . . . . . . . . . . . . . . . . .

MAINTENANCE

18--19

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Air Filter

18

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Indoor Blower and Motor

18

. . . . . . . . . . . . . . . . . . . . . . . . . .

Outdoor Coil, Indoor Coil, and Condensate Drain Pan

19

. . . .

Outdoor Fan

19

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Electrical Controls and Wiring

19

. . . . . . . . . . . . . . . . . . . . . .

Refrigerant Circuit

19

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Indoor Airflow

19

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Metering Devices–AccuRater

®

Piston

19

. . . . . . . . . . . . . . . .

TROUBLESHOOTING

19

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

START--UP CHECKLIST

19

. . . . . . . . . . . . . . . . . . . . . . . . . . .

C99001

Fig. 1 -- Unit 50SD

SAFETY CONSIDERATIONS

Installation and servicing of this equipment can be hazardous due to

mechanical and electrical components. Only trained and qualified

personnel should install, repair, or service this equipment.
Untrained personnel can perform basic maintenance functions such

as cleaning and replacing air filters. All other operations must be
performed by trained service personnel. When working on this

equipment, observe precautions in the literature, on tags, and on

labels attached to or shipped with the unit and other safety
precautions that may apply.
Follow all safety codes. Installation must be in compliance with
local and national building codes. Wear safety glasses, protective

clothing, and work gloves. Have fire extinguisher available. Read
these instructions thoroughly and follow all warnings or cautions

included in literature and attached to the unit.

Recognize safety information. This is the safety--alert symbol

.

When you see this symbol on the unit and in instructions or manuals,

be alert to the potential for personal injury. Understand these signal

words: DANGER, WARNING, and CAUTION. These words are
used with the safety--alert symbol. DANGER identifies the most se-

rious hazards which

will

result in severe personal injury or death.

WARNING signifies hazards which

could

result in personal injury

or death. CAUTION is used to identify unsafe practices which

may

result in minor personal injury or product and property damage.
NOTE is used to highlight suggestions which

will

result in en-

hanced installation, reliability, or operation.

Summary of Contents for 50SD024

Page 1: ...Rater Piston 19 TROUBLESHOOTING 19 START UP CHECKLIST 19 C99001 Fig 1 Unit 50SD SAFETY CONSIDERATIONS Installation and servicing of this equipment can be hazardous due to mechanical and electrical com...

Page 2: ...re that the fan discharge does not recirculate to the outdoor coil Do not locate the unit in either a corner or under an overhead obstruction The minimum clearance under a partial overhang such as a n...

Page 3: ...UNIT 2 00 50 8 SIDE OPPOSITE DUCTS 14 00 355 6 BOTTOM OF UNIT 0 50 12 7 NEC REQUIRED CLEARANCES INCHES mm BETWEEN UNITS POWER ENTRY SIDE 42 00 1066 8 UNIT AND UNGROUNDED SURFACES POWER ENTRY SIDE 36...

Page 4: ...m BETWEEN UNITS POWER ENTRY SIDE 42 00 1066 8 UNIT AND UNGROUNDED SURFACES POWER ENTRY SIDE 36 00 914 0 UNIT AND BLOCK OR CONCRETE WALLS AND OTHER GROUNDED SURFACES POWER ENTRY SIDE 42 00 1066 8 Refer...

Page 5: ...port CTyp G E F G D E A05308 UNIT SIZE ODS CATALOG NUMBER A IN MM B IN MM C IN MM D IN MM E IN MM F IN MM G IN MM 50SD024 030 CPRFCURB006A00 8 203 11 279 16 1 2 419 28 3 4 730 30 3 8 771 44 5 16 1126...

Page 6: ...follow this warning could result in personal injury or death Never stand beneath rigged units or lift over people WARNING INSTALLATION The lifting rigging bracket is engineered and designed to be ins...

Page 7: ...Be sure to check the drain tube for leaks Prime trap at the beginning of the cooling season start up 1 25mm MIN 2 50mm MIN TRAP OUTLET C99013 Fig 8 Condensate Trap Step 7 Install Duct Connections Thed...

Page 8: ...sion of vibration The transition may be screwed or bolted to duct flanges Use suitable gaskets to ensure weather tight and airtight seal 4 All units must have field supplied filters or accessory filte...

Page 9: ...res connected to the line side of the contactor 4 Connect field L1 to black wire on connection 11 of the compressor contactor 5 Connect field wire L2 toyellow wireon connection13 ofthe compressor cont...

Page 10: ...erminals 3 Never attempt to repair soldered connection while refrigerant system is under pressure 4 Do not use torch to remove any component System contains oil and refrigerant under pressure 5 To rem...

Page 11: ...83 3 80 90 208 230 3 60 187 253 11 7 88 0 0 9 4 1 19 6 19 6 25 25 3 8 5 0 10 4 12 0 19 6 20 2 25 25 7 2 10 0 20 8 24 1 31 2 35 2 35 40 11 3 15 0 31 3 36 1 44 2 50 2 15 0 20 0 41 7 48 1 57 2 65 3 60 7...

Page 12: ...n time delay expires when FAN switch is placed in AUTO position 2 Place SYSTEM switch in COOL position and FAN switch in AUTO position Set cooling control below room temperature Observe that compresso...

Page 13: ...604 1538 1457 1362 1271 High Watts 798 772 738 700 CFM 1720 1648 1540 1414 048 Low Watts 627 617 607 584 567 548 528 503 CFM 1550 1530 1493 1461 1414 1361 1320 1250 Med Watts 771 755 734 711 690 665 6...

Page 14: ...14 A05112 Fig 13 Wiring Diagram 208 230 1 60 50SD...

Page 15: ...15 A06307 Fig 14 Wiring Diagram 208 230 3 60 50SD...

Page 16: ...16 A06485 Fig 15 Wiring Diagram 460 3 60 50SD...

Page 17: ...o change the speed of the indoor fan motor IFM remove the fan motor speed leg lead from the time delay relay TDR This wire is attached to terminal 3 of TDR for 3 phase units To change the speed remove...

Page 18: ...g season Clean when necessary 4 Check electrical connections for tightness and controls for proper operation each cooling season Service when necessary 5 Ensure electric wires are not in contact with...

Page 19: ...e grille ELECTRICAL CONTROLS AND WIRING Inspect and check the electrical controls and wiring annually Be sure to turn off the electrical power to the unit Remove access panel to locate all the electri...

Page 20: ...e cause Insufficient line voltage Determine cause and correct Blocked outdoor coil Determine cause and correct Defective run start capacitor overload or start relay Determine cause and replace Faulty...

Page 21: ...AIR FILTER IS CLEAN AND IN PLACE VERIFY THAT UNIT INSTALLATION IS LEVEL CHECK FAN WHEEL AND PROPELLER FOR LOCATION IN HOUSING ORIFICE AND SETSCREW TIGHTNESS III START UP ELECTRICAL SUPPLY VOLTAGE ____...

Page 22: ...t 2006 Carrier Corporation Printed in the U S A Edition Date 09 06 Catalog No 50SD 4SI Replaces 50SD 3SI Manufacturer reserves the right to change at any time specifications and design without notice...

Reviews: