49
Country
Category Gas
Pressure
(mbar)
Gas
Pressure
(mbar)
Italy, Ireland,
Great Britain,
Portugal,
Slovenia,
Slovakia, Greece
II2H3+
G20
20
G30/G31 28-30/37
Spain
II2H3+
G20
18
G30/G31 28-30/37
Romania,
Bulgaria,
Turkey, Denmark,
Estonia, Sweden,
Norway, Latvia,
Lithuania,
Finland, Russia,
II2H3B/P
G20
20
G30
30
Hungary
II2H3B/P
G20
25
G30
30
Poland
II2H3B/P
G20
25
G30
37
Croatia
II2H3B/P
G20
20
G30/G31 30
Holland
II2H3B/P
G25
25
G30
30
Czech Republic,
Austria,
Switzerland
II2H3B/P
G20
20
G30
50
Luxembourg
II2H3B/P
G20
20
G30
50
II2E3P
G20
20
G31
37
Belgium
I2E(S) G20/G25 20/25
--
--
I3+
--
--
G30/G31 28-30/37
France
II2E+3+,
G20/G25 20/25
G30/G31 28-30/37
Malta, Cyprus,
Iceland
I3B/P
--
--
G30
30
Germany
II2ELL3B/P G20/G25 25
G30
50
Identi
fi
cation of the boiler
The boiler can be identi
fi
ed as follows:
1
2
B23-B53-B53p (C63, C63X)
European Directive
92/42/EEC:
RIELLO S.p.A.
Via Ing.Pilade Riello, 7
37046 Legnago (VR) -
Gas type:
Category:
IT
CONDEXA PRO 100
Caldaia a condensazione - Chaudierè a condensation - Brennwertkessel - Condenserende verwamingsketel
G20
G25
Qn(max)=
Cod.
N°
Pn(max)=
Qn(min)=
IT: G20=20 mbar G30=28-30 mbar G31=37 mbar
Pn(min)=
20115226
19,4
-
6
P.min.G20= 20 mbar
IP
G20 - 20 mbar
230V ~ 50Hz 150 W
FC145000263
0085 /
0085CP0214
NOx:
bar
T=90°C
5
X0D
kW
95,16
19,0
97
kW
kW
kW
kW
kW
kW
kW
T067692GE
-
-
-
II2H3+
17
CALDAIA REGOLATA PER:
CHAUDIERE REGLEE POUR:
KESSEL GEREGELT FUR:
VERWARMINGSKETEL INGESTELD OP:
KEDEL REGULERET TIL:
CENTRALA REGLATA PENTRU:
A KAZAN AZ ALABBI ADAKTORA LETT BEALLITVA:
PAESE DI DESTINAZIONE:
PAYS DE DESTINATION:
LAND VON BESTEMMING:
BESTIMMUNGSLAND:
LAND,HVOR KEDLEN SKAN INSTALLERES:
TARA DE DESTINATIE:
RENDELTETESI ORSZAG:
PMS=
FI
FI
FI
G2
Key:
Central heating section
Qn
Rated heat input
Pn
Rated useful heat output
IP
Electric degree of protection
Pmw
Maximum operating pressure, DHW circuit
Pms
Maximum operating pressure, CH circuit
T
Temperature
ɳ
E
ffi
ciency
D
Speci
fi
c
fl
ow rate
NOx
NOx class
2- Gas label:
Is located on the appliance’s side and states the type of fuel used
and the country of destination:
12 - FACTORY OPTIONS AND ACCESSORIES
1- Technical data plate:
This plate indicates the technical and performance data.
This manual and the manufacturer’s manual must be kept
with care. If it is lost or damaged, please contact the Technical
Assistance Service for a new copy.
The thermal module, before being connected to the hydraulic
system, the gas network, and the electrical system, may be
exposed to temperatures ranging from 4°C to 40°C. After it can
activate the Frost Protection function.
Regularly check that the condensate drain is free from
obstruction.
We recommend cleaning inside the exchanger once a year,
extracting jet and burner and removing any installation debris
by suction. This operation will be done by personnel from the
Technical Assistance Service only.
■
Basic safety rules
The operation of any appliance that uses fuel, electrical power
and water demands that a number of fundamental safety
precautions be respected. It is forbidden:
- To use electrical devices or equipment, such as switches,
appliances, etc. if there is a smell of gas or unburnt products.
If so:
• Close the fuel shut-o
ff
cock.
• Report the fault immediately to the Technical Assistance
Service or a professionally quali
fi
ed heating engineer.
• Any technical or cleaning activity is forbidden before
disconnecting the boiler from the main power supply by
switching the magnetothermic switch placed in the electrical
cabinet of the 50FF/FC unit.
- To tamper with or adjust the safety or control devices without
prior authorisation and instructions from the manufacturer.
- To pull, disconnect, or twist the electrical cables coming from
the boiler even if it is disconnected from the mains electricity
supply.
- To plug or block the condensate drain outlet
- To switch o
ff
the appliance if the outdoor temperature may
drop to below ZERO (frost hazard).
- To activate the thermal module without water.
■
Safety devices
The triggering of safety devices indicates the malfunction of
a potentially hazardous thermal module. Therefore, contact
Technical Assistance Service immediately. After a brief pause,
it is possible to try and restart the appliance.
Safety devices must be replaced by Technical Assistance
Service, using only original parts. Refer to the spare parts
catalogue supplied with the appliance. After making the repair,
check that the appliance is working properly.
The appliance must not be put in service, even temporarily,
when tampered safety devices are not in operation or have
been tampered with.