INITIAL START-UP

Location

Maximum Permitted Value

Procedure

1) External air temperature 43

o

C

For temperature exceeding 43

o

C, consult your

(Units with air

Carrier representative.

condensation)

2) Voltage

Variation of 

±

 10% in relation

Check the installation and/or contact your local

to the nominal value

electrical power company.

3) Unbalancing of the

Voltage: 2%

Check the installation and/or contact your local

network (48,000 and

Current: 10%

electrical power company.

60,000 Btu/h units)

4) Distance and vertical

Refer technical spec

For greater distances, consult your Carrier

gap between the units

representative.

ATTENTION !!!

ATTENTION !!!

The table below defines the limits and conditions for the application and operation of the
units.

Table of Conditions and Limits for Application and Operation

Before starting up the unit, observe the above conditions and the following items:

Check that all of the electrical connections are securely connected;

Check that there are no leaks of refrigerant;

Confirm that the force discharge is compatible with the electrical specifications of the unit;

Ensure that the compressors can move freely above the vibration insulators of the outdoor
unit;

Ensure that all of the service valves are in the correct operating position (open);

Ensure that area around the outdoor unit (condensing unit) is free of any obstructions the
air intake and discharge;

Confirm that perfect drainage occurs and that the drainage hose is not blocked.

The fan motors of the units are lubricated in the factory. DO NOT lubricate them  again
when installing the units. Before starting up the motor, verify that the propeller or turbine
of the fan is not loose.

In outdoor unit assembled exclusively with Scroll-type compressors, the noise of
these compressors must be heard after start-up. If this noise is high and the
pressures are the same after start-up, invert the two feed phases! This procedure is
compulsory and failure to perform it will invalidate the warranty of the equipment.

Summary of Contents for 42XQ Series

Page 1: ...AND START UP INSTRUCTIONS UNDERCEILING CONSOLE FAN COIL UNIT 42XQ XQA 50 60Hz Carrier International Sdn Bhd Malaysia 42XQ 42XQA MODEL W mm D mm H mm Weight kg 42XQ XQA 020 004 23 42XQ XQA 025 006 102...

Page 2: ...2 Electrical Box 42XQ 16 7 3 Changing the Wireless Remote Control to a Wired Remote Control 17 7 4 Electrical Diagram for Indoor Unit 220 240V output signal to compressor 20 7 5 Electrical Diagram for...

Page 3: ...extinguisher periodically to verify that it is completely full and work perfectly Whenever working on the equipment always pay attention to all safety notices written on the labels attached to the uni...

Page 4: ...being exposed to possible work accidents and arrange for their immediate transfer to the place of installation or another safe location When unpacking the units and removing the protective expanded p...

Page 5: ...ded particulate matter which could possibly obstruct the vanes of the outdoor unit It is essential for the indoor unit to posses a hydraulic line to drain off the condensate This hydraulic line must h...

Page 6: ...sewerage systems etc b Install the unit where it is free of any kind of obstruction of the air circulation both in the air intake and the air discharge c Select a location with sufficient space to per...

Page 7: ...4 3 2 PLACEMENT AT THE LOCATION NOTE To fix the indoor unit in place it is necessary to remove its side covers as described in subsection 4 3 3 d Fig 8 indicates the position of the supports Install t...

Page 8: ...s the left side gives access to the electrical box and the electrical connections 4 3 3 REMOVING THE SIDES 1 2 Fig 10 shows the position of the screws to be removed to disassemble the grilles which gi...

Page 9: ...llations on the wall and ceiling and where these pipes must be routed as well as where it is necessary to break the indentation in the right hand side cover of the indoor unit 4 3 5 DRAINING OF THE CO...

Page 10: ...l with a slight inclination towards the drainage side approximately 2o Fig 14 b The unit uses gravity drainage However the drainage pipe must have a downward slope Avoid the situation shown in Fig 15...

Page 11: ...olding charge For more information regarding the additional gas load refer to the table below IMPORTANT Note Model code for Thailand market only Outdoor unit connection for reference only refer to spe...

Page 12: ...condenser The surfacemustbecleanandthemeasurement is performed on the upper part of the pipe to prevent incorrect readings Cover the bulb or sensor with foam to insulate it from the ambient temperatur...

Page 13: ...indicated for the pipes giving consideration to the fact that it is the result of adding the equivalent distances of the pipe curves in a straight line 5 5 Interconnection Junctions The equivalent len...

Page 14: ...st or humidity entering the pipe until it is used Take care to place refrigeration oil on the surfaces in contact between the flanged end and the joint before connecting them together This is done to...

Page 15: ...to the adjacent illustration 6 EXPANSION SYSTEM This system with a piston according to Fig 22 contains a small part with a fixed calibrated orifice which is easily removed on the inside of a nipple fo...

Page 16: ...ith local codes For the cable gauge values of the main power supply presented in the tables the use of copper and or aluminium cables was considered with insulation of the PVC 70o C type and conductor...

Page 17: ...to use the indoor unit from the wireless remote control to the wired remote control the following steps must be followed according to the illustrations on the following pages Disconnect the intermedia...

Page 18: ...18 Fig 25 Changing the remote control use option external connections...

Page 19: ...emote control to connect the threeway cable The terminals are located in the rear part of the cover Insert the cables in the terminals according to the correspondence of the colors Reattach the cover...

Page 20: ...20 Electrical interconnection in the Terminal Plate of the Indoor Unit 42XQ 7 4 Electrical Diagram for Indoor Unit 220 240V output signal to compressor Fig 26 Fig 27...

Page 21: ...21 Electrical interconnection in the Terminal Plate of the Indoor Unit 42XQ 7 5 Electrical Diagram for Indoor Unit 24V output signal to compressor Fig 28 Fig 29...

Page 22: ...22 7 6 Electrical Diagram and Cold Cycle Interconnection Diagram 50Hz Cooling only ELECTRICAL INTERCONNECTION 42XQ XQA 020 025 42XQ XQA 030 42XQ XQA 040 050 060...

Page 23: ...er with respect for the steps described from Section 8 3 onwards 8 CONFIGURING THE SYSTEM 8 1 Changing the Configuration of the Unit from Underceiling to Console The indoor units leave the factory con...

Page 24: ...ss the button to exit the configuration menu To see other available configuration options consult the table 8 3 Configuring the Unit Remote address of indoor unit A Remote address of indoor unit B Def...

Page 25: ...A remote unit A Remote address of indoor unit A b remote unit B Remote address of indoor unit B Ab remote units A and B Default address of the two units tU C degree Celsius Temperature F degree Fahre...

Page 26: ...tem Value Description 20 1 Heatpump Configuration of the unit 0 Only A C Use as default Heat Cool 21 1 199 in increments of 1 CNN address of the unit Use as default 1 22 0 199 in increments of 1 Zone...

Page 27: ...d temperature setpoint is automatically readjusted to the default startup values of 22o C for C mode and 72o F for F mode whenever this configuration item is modified Item Value Description 10 H Remot...

Page 28: ...ed the last value displayed is the new deflector setting for the system The only way to abort a deflector change is to change the value back to its original value ATTENTION NOTE Selecting DEFLECTOR mo...

Page 29: ...tion item CH remote address and the temperature digits show the default value of the respective configuration item Ab control of both indoor units Press the buttons or to change the default value Ab t...

Page 30: ...ion If the sensor temperature of the indoor unit coil does not fluctuate within the range 2o C during the compressor cycle period of 5 minutes the control triggers this error 10 EEPROM error in circui...

Page 31: ...the electrical connections are securely connected Check that there are no leaks of refrigerant Confirm that the force discharge is compatible with the electrical specifications of the unit Ensure that...

Page 32: ...TO OUTDOOR COMPRESSOR Carrier International Sdn Bhd 3385 T Lot 4 Jalan P 6 43650 Bandar Baru Bangi Selangor Malaysia Tel 03 8925 8001 Fax 03 8925 3578 REV 2 42XQ 06 2006 Parent Pt No 42XQ 402 001 IOM...

Reviews: