25
•
Insert the batteries into the remote control and leave it disconnected.
•
Connect the system to the electrical current.
•
Press the button and the remote control and keep them pressed down for at least
5 seconds.
•
The clock digits show the first configuration item (CH = remote address) and the
temperature digits show the default value of the respective configuration item
(Ab = control of both indoor unit).
•
Press the button repeatedly until “rc” appears.
•
Press the buttons or to change the default value (HP) to the new value
(AC).
•
Press the button to send the new configuration to the unit.
•
Press the button to exit the configuration menu.
To see other available configuration options, consult the table.
8.4
Configuring the Wireless Remote Control
<
<
<
Display
Explanation
Description on the viewfinder
Item
“CH”
“A” : remote unit A
Remote address of indoor unit A.
“b” : remote unit B
Remote address of indoor unit B.
“Ab” : remote units A and B
Default address of the two units.
“tU”
“C” : degree Celsius
Temperature.
“F” : degree Fahrenheit
The default is
o
C.
“rc”
“HP” : Heatpump
Default address and heatpump.
“AC” : Cooling only
Changes the address to cooling only.
“HR”
17 - 32 : 17
o
C - 32
o
C
Maximum heating temperature in
o
C.
63 - 90 : 63
o
F - 90
o
F
Maximum heating temperature in
o
F.
“CR”:
17 - 32 : 17.22
o
C - 32.22
o
C
Minimum Cooling temperature in
o
C.
63 - 90 : 63
o
F - 90
o
F
Minimum Cooling temperature in
o
F.
“CL”
12 : 12 : 12-hour clock (AM/PM) Time format (AM = morning; PM =
24 : 24 : 24-hour clock
afternoon). The default is 12 : 12.
NOTE
If the selection is changed from “rc” (functioning in the heatpump) to cooling
only and the remote control is automatic function mode or heating mode,
the function mode is set to cold.
If no button is pressed for 30 seconds, the remote control automatically
exits the configuration menu and the entire procedure must be restarted.
NOTE