42VMC

GB - 4

Unit installation

Read this instruction manual thoroughly before starting the
installation.

• This unit complies with low-voltage (EEC/73/23) and electro-

magnetic compatibility (EEC/89/336) directives.

• The installation must be carried out by a qualified installer.

• Follow all current national safety code requirements. In particular

ensure that a properly sized and connected ground wire is in place.

• Check that voltage and frequency of the mains power supply are

those required for the unit to be installed; the available power
must be adequate to operate any other possible appliances
connected to the same line.
Also ensure that national safety code requirements have been
followed for the mains supply circuit.

• The mains supply must be connected as follows:

Models 42VMC 009, 012, 014: to the indoor unit.
Models 42VMC 018, 024: to the outdoor unit.

• Connect indoor and outdoor units with field-supplied copper pipes

by means of flare connections. Use insulated seamless
refrigeration grade pipe only, (Cu DHP type according to ISO 1337),
degreased and deoxidized, suitable for operating pressures of at
least 4200 kPa.
Under no circumstances must sanitary type copper pipe be used.

• Use field-supplied 16 mm I.D. PVC pipe of appropriate length and

with the correct thermal insulation for the condensate drain.

• After installation thoroughly test the system operation and explain

all system functions to the owner.

• Leave this manual with the owner for consultation during future

periodic maintenance.

• Use this unit only for factory approved applications: the unit

cannot be used in laundry or steam pressing premises.

IMPORTANT:
During the unit installation make first refrigerant connections
and then electrical connections. When disassembling first
disconnect electrical cables, then refrigerant connections.

WARNING:
Disconnect the mains power supply switch before servicing
the system or handling any internal parts of the unit
.

• Do not open the remote controller to avoid possible damage.

In case of  malfunctioning contact a qualified service engineer.

• This installation manual describes the installation procedures of

the indoor unit of a residential split system consisting of two units
manufactured by Carrier.
Consult factory or a qualified system engineer prior to connecting
this unit to any other manufacturer's outdoor unit.
Coupling units which have different control systems, may cause
irreversible damage and void the warranty protection.
The manufacturer declines any liability for system malfunction
resulting from unapproved coupling.

• Operating conditions outside the operating range

(“Connections”), will cause safety device tripping or damage to
unit components.

• The manufacturer declines any liability for damage resulting from

modifications or errors in the electrical or refrigerant connections.
Failure to observe the installation instructions or use of the unit
under conditions other than those indicated in Table III (operating
limits) of the outdoor unit installation manual, will immediately
void the unit warranty.

General information

• Failure to observe electric safety codes may cause a fire hazard in

case of short circuits.

• Inspect equipment for damage due to improper transportation or

handling: file an immediate claim with the shipping company.
Do not install or use damaged units.

• In case of any malfunctioning turn the unit off, disconnect the

mains power supply and contact a qualified service engineer.

• This equipment contains R-410A refrigerant, a substance that is

not depleting the ozone layer.

• All of the manufacturing and packaging materials used for

your new appliance are compatible with the environment and
can be recycled.

• Dispose of the packaging material in accordance with local

requirements.

• This equipment contains refrigerant that must be disposed of in

the proper manner.
When disposing of the unit after its operational life, remove it
carefully.
The unit must then be delivered to an appropriate disposal centre
or to the original equipment dealer, for proper environmentally
friendly disposal.

Choosing the installation site

Positions to avoid:

• Exposed to direct sun.

• Too close to heat sources.

• On humid walls or positions with water hazard, e.g. laundry premises.

• Where curtains or furniture may obstruct free air circulation.

Recommendations:

• Choose an area free from obstructions which may cause irregular

air distribution and/or return.

• Check that the wall surface is flat enough to allow easy and safe

installation.
The wall structure should be strong enough to carry the unit
weight and avoid deformation, rupture or vibration during
operation.

• Consider using an area where installation is easy.

• Choose a position that allows for the clearances required (see drawing).

• Look for a position in the room which assures the best possible air

distribution.

• Install the unit in a position where condensate can easily be piped

to an appropriate drain.

Summary of Contents for 42VMC Console night & day

Page 1: ...42VMC Console T h e S t andards Institutiono f I s r a e l Q u ality Assured Fi r m SI ISO 9001 INSTALLATION MANUAL...

Page 2: ...ge Dimensions and weight 2 Nominal data 2 Minimum clearances 2 Connections 3 Material supplied 3 Operating limits 3 General information 4 Warnings avoid 5 Installation 6 7 Refrigerant connections 8 El...

Page 3: ...m 540 540 600 600 600 kg kg 15 16 18 18 20 Table I Nominal data Unit is not suitable for operation in laundry premises For sizing of power supply wires and delay type fuses refer to the outdoor unit i...

Page 4: ...g limits Cooling Heating Refer to outdoor unit installation manual Mains power supply Nominal single phase voltage 230V 50Hz Operating voltage limits min 198V max 264V Photocatalytic filter Acrylic fi...

Page 5: ...its which have different control systems may cause irreversible damage and void the warranty protection The manufacturer declines any liability for system malfunction resulting from unapproved couplin...

Page 6: ...lose to heating sources which may damage the unit connecting condensate piping to sewage system drain without appropriate trap Trap height must be calculated according to the unit discharge head in or...

Page 7: ...grille To remove suction grille remove the central lock using a pliers then with a screwdriver remove the two side screws fixing the fasteners Locate the mounting template supplied with the unit Insta...

Page 8: ...ections see illustra tion For exit to the rear the wall hole must be made in the position shown in the illustration Drill a 70 or 80 mm diameter hole The hole must have a 5 10 mm downward slope toward...

Page 9: ...s Liquid Model Suction Discharge mm inches mm inches 009 9 52 3 8 6 35 1 4 012 12 70 1 2 6 35 1 4 014 12 70 1 2 6 35 1 4 018 12 70 1 2 6 35 1 4 024 12 70 1 2 6 35 1 4 For refrigerant tubes use seamles...

Page 10: ...gap of a least 3 mm The indoor outdoor unit connecting wires must be A07 RN F type or higher with synthetic rubber insulation with Neoprene coating according to EN 60335 2 40 and HD277 S1 codes The m...

Page 11: ...ng contact Mains supply connecting cable field wiring Connecting cable indoor outdoor units field wiring Indoor unit Outdoor unit Main switch Time delay fuse or circuit breaker see outdoor unit instal...

Page 12: ...ction indoor outdoor unit R Live connection indoor outdoor unit C Neutral connection indoor outdoor unit Y Compressor interlocking contact O Reversing valve control W2 Outdoor fan signal S Defrost end...

Page 13: ...ng temperature range F min and max CL 12 12 12 hour clock AM PM Time format AM morning PM afternoon 24 24 24 hour clock Default is 12 12 Table IV Item Shown on Explanation Description display A remote...

Page 14: ...ol and hold them pressed for more than 5 seconds The display will be cleared the temperature segments will display the first configuration item CH remote address and the time segments will display the...

Page 15: ...pplied separately and controlled by a bipolar ON OFF switch with safety fuses field installed To adjust the fan motor air flow to the required values it is advisable to install a speed controller Fres...

Page 16: ...nzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice Order No 14489 74 April 2002 Supersedes Order No 14489 74 Januar...

Reviews: