To decrease the display lamp brightness or turn it off.
  1.  Press and hold 

  for 3 seconds until brightness level ( ,  ,

   

 or  ) is shown on remote control LCD then release the button.

 

2.  Press 

 

Rise

 or 

Decrease

 

 

to adjust brightness in 4 levels.

DISPLAY LAMP BRIGHTNESS ADJUSTMENT

9

Remote control

LCD

Operation display

Brightness

Lamp illuminates full brightness.

100%

Lamp illuminates 50% brightness.

50%

Lamp illuminates 50% brightness and the

operation lamp is turned off.

50%

All lamps are turned off.

All turned off

● In the examples of   and  , the lamp illuminates for 5 seconds before

  going off.

AUTO RESTART FUNCTION SETTING

10

This product is designed so that, after a power failure, it can restart automatically

in the same operating mode as before the power failure.

Information

  The product is shipped with Auto Restart function in the ON position.

  Turn it OFF if this function is not required.

How to turn OFF the Auto Restart Function

●  Press and hold the [OPERATION] button on the indoor unit for 3 seconds

   (3 beep sounds but OPERATION lamp does not blink).

How to turn ON the Auto Restart Function

●  Press and hold the [OPERATION] button on the indoor unit for 3 seconds

   (3 beep sounds and OPERATION lamp blink 5 time/sec for 5 seconds).

Notes :

●  In case of ON timer or OFF timer are set, AUTO RESTART OPERATION

   does not activate.

●  Default setting of AUTO RESTART OPERATION is ON.

SELF CLEANING OPERATION 

(COOL AND DRY OPERATION ONLY)

11

To protect bad smell caused by the humidity in the indoor unit.
  1.  If the 

 button is pressed once during “Cool” or “Dry” mode,

    the fan will continue to run for other 30 minutes, then it will turn off

    automatically. This will reduce the moisture in the indoor unit.
  2.  To stop the unit immediately, press the 

 more 2 times within  

    30 seconds.

TEMPORARY OPERATION

12

In case of the misplaced or discharged remote control

  ●  Pressing the RESET button, the unit can start 

    or stop without using the remote control.

  ●  Operation mode is set on AUTOMATIC 

    operation, preset temperature is 24°C and fan    

    operation is automatic speed.

REMOTE CONTROL A-B SELECTION

13

To separate using of remote control for each indoor unit in case of 2 air

conditioners are installed nearly.

Remote Control B Setup.

  1. Press RESET button on the indoor unit to turn the air conditioner ON.

  2. Point the remote control at the indoor unit.
  3. Push and hold   button on the back side of Remote Control “00” will be  

    shown on the display. (Picture 

1

)

  4. Press 

 during pushing   . “B” will show on the display and

    “00” will disappear and the air conditioner will turn OFF. The Remote

    Control B is memorized. (Picture 

2

)

Note:

 1. Repeat above step to reset Remote Control to be A.

      2. Remote Control A has not “A” display.

      3. Default setting of Remote Control from factory is A.

1

2

OPERATION AND PERFORMANCE

14

1.  Three-minute protection feature: To prevent the unit from being activated  

  for 3 minutes when suddenly restarted or switched to ON.

2.  Some minor cracking sound may occur when unit operating. This is  

  normal because the cracking sound may be caused by expansion/

  contraction of plastic.

Air conditioner operating conditions

Temp.

Operation

Outdoor Temperature

Room Temperature

Cooling

‒10°C ~ 46°C

21°C ~ 32°C

Dry

‒10°C ~ 46°C

17°C ~ 32°C

MAINTENANCE

15

TROUBLESHOOTING (CHECK POINT)

16

 Firstly, turn off the circuit breaker.

Indoor Unit and Remote Control

  ●  Clean the indoor unit and the remote control with a wet cloth when 

     needed.

  ●  No benzine, thinner, polishing powder or chemically-treated duster.

Air filters

Clean every 2 weeks.

   1. Open the air inlet grille.

   2. Remove the air filters.

   3. Vacuum or wash and then dry them.

   4. Reinstall the air filters and close the air inlet grille.

The unit does not operate.

Cooling or Heating is abnormally low.

●  The power main switch is

turned off.

●  The circuit breaker is activated 

to cut off the power supply.

●  Stoppage of electric current

●  ON timer is set.

●  The filters are blocked with dust.

●  The temperature has been set

improperly.

●  The windows or doors are opened.

●  The air inlet or outlet of the outdoor

unit is blocked.

●  The fan speed is too low.

●  The operation mode is FAN or DRY.

●  POWER SELECTION function is 

set 75% or 50% 

(This function is

    depend on remote controller).

Summary of Contents for 42TVAB010

Page 1: ...OWNER S MANUAL ENGLISH AIR CONDITIONER SPLIT TYPE For general public use Indoor unit 42TVAB010 013 018 024 028 030 033 Serise Outdoor unit 38TVAB010 013 018 024 028 030 033 1122350217...

Page 2: ...expose your body directly to cool or warm air for a long time Do not insert your finger or any article into the air inlet outlet When an abnormality burning smell etc occurs stop the air conditioner a...

Page 3: ...ppliance in kg h0 is the installation height of the appliance in m 0 6 m for floor standing 1 8 m for wall mounted 1 0 m for window mounted 2 2 m for ceiling mounted For these units recommend installa...

Page 4: ...tter Start Stop button Mode select button Temperature button Fan speed button Menu select button Set louver Up Down button Set louver Left Right button Check button Check button under battery cover 1...

Page 5: ...ure by press MENU button again When feature had selected will return to menu selection display triangle mark will blink 5 Leave from menu setting display by select exit and press menu button Leave fro...

Page 6: ...ing capacity and the Sound level of outdoor unit Compromising the Cooling capacity to the Sound level in any circumstance where the outdoor unit s sound level is highly prioritized This setting has a...

Page 7: ...by plasma ion contaminates such as bacteria odor smoke dust and virus are caught and deactivated by Plasma Ion 1 Press MENU button for enter menu setting and press TEMP button to select PURE This func...

Page 8: ...perature is 24 C and fan operation is automatic speed REMOTE CONTROL A B SELECTION 13 To separate using of remote control for each indoor unit in case of 2 air conditioners are installed nearly Remote...

Page 9: ...R32 3 8 TH...

Page 10: ...R32 Amin m2 Amin m2 Amin M 2 5 x 0 22759 x h0 2 M h0 0 6 1 8 1 0 2 2 2 5...

Page 11: ...2 3 4 1 2 3 4 5 6 7 8 9 5 6 7 1 1 3 4 5 2 1 Wi Fi 2 ECO 3 PURE 4 5 9 Wirelass LAN connecting adapter 1 2 17 C 30 C 3 AUTO LOW LOW MED MED HIGH Quiet 1 Auto A 2 17 C 30 C 3 AUTO LOW LOW MED MED HIGH Q...

Page 12: ...8 Hi power 8 1 H DA 1 MENU TEMP 2 MENU Louver set Setting feature 3 TEMP H DA 4 MENU 5 EXIT V H FIX H DA H DA H DA H DA...

Page 13: ...Two purpose 1 2 1 2 Faster cooling operation DRY and FAN ONLY 1 MENU HI POWER DRY and FAN ONLY 1 MENU 2 MENU 2 MENU 3 EXIT 3 EXIT 1 2 1 MENU 2 MENU 3 TEMP 4 MENU 5 EXIT 1 2 TEMP 8 3 Hi P 8 4 ECO 1 2 2...

Page 14: ...8 5 1 MENU 2 MENU 3 TEMP 0 5 12 4 MENU 5 EXIT 6 5 MENU TEMP 7 MENU 8 EXIT 8 7 8 6 PURE Odor 1 MENU TEMP PURE 100 75 50 POWER SELECTION 1 MENU TEMP 2 MENU 3 TEMP 100 75 50 2 MENU 3 EXIT 4 MENU 5 EXIT...

Page 15: ...ation Auto Restart Operation 3 3 Operation 5 5 AUTO RESTART ON 11 1 3 2 4 1 30 2 2 30 12 RESET AUTO 24 C A B 13 1 2 14 B 1 RESET 2 3 00 1 4 B 00 B 2 1 A 2 A A 3 A 1 3 3 ON 2 Cool 10 C 46 C 21 C 32 C D...

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...1122350217...

Reviews: