background image

PREPARATION BEFORE USE

2

Preparing Filters

  1.  Open the air inlet grille and remove the air filters.

  2.  Attach the filters. (see detail in the Installation Manual).

Loading Batteries (when use wireless operation.)

  1. Remove the slide cover.

  2. Insert 2 new batteries (AAA type)

    following the (+) and (–) positions.

Remote Control Reset

  1. Remove the batteries.
  2. Press 

.

  3. Insert the batteries.

AIR FLOW DIRECTION

3

1

Press 

  : Move the 

louver in the desired vertical 

direction.

2

Press 

  : Move the

louver in the desired horizontal

direction.

3

SWING operation can be

selected from MENU button

Swing off

Vertical 

(Up-Down)

Swing

Horizontal 

(Left-Right)

Swing

Vertical and 

Horizontal

Swing

HADA CARE 

FLOW

● Vertical (Up-Down) swing

● Horizontal (Left-Right) swing

● HADA Care flow

Note:

  ●  Do not move the louver manually by others.

  ●  The louver may automation positioning by some operation mode.

REMOTE CONTROL

4

Infrared signal emitter
Start/Stop button
Mode select button
Temperature button
Fan speed button
Menu select button
Set louver Up-Down button
Set louver Left-Right button
Check button*
*Check button under battery cover

1
2
3
4
5
6
7
8
9

COOLING / FAN ONLY OPERATION

5

1. Press 

 : Select Cool  , or Fan only  . 

2. Press 

 : Set the desired temperature. Min. 17°C, Max. 30°C.

  Fan Only: No temperature indication

3. Press 

 : Select AUTO, LOW  , LOW+  , MED 

,

  MED+ 

, HIGH 

 or Quet 

AUTOMATIC OPERATION

6

To automatically select cooling, heating, or fan only operation

  1. Press 

 : Select Auto A.

  2. Press 

 : Set the desired temperature. Min. 17°C, Max. 30°C. 

 
  3. Press 

 : Select AUTO, LOW  , LOW+  , MED 

,

    MED+ 

, HIGH 

 or Quet 

DRY OPERATION

7

For dehumidification, a moderate cooling performance is controlled

automatically.
  1. Press 

 : Select Dry   .

  2. Press 

 : Set the desired temperature. Min. 17°C, Max. 30°C.

 

Note:

 DRY mode fan speed is set to Auto only.

INDOOR UNIT DISPLAY

1

1

3

4

5

2

1

 Wi-Fi access (White) 

2

 ECO (White)

3

 PURE (White)

4

 Timer (White)

5

 Operation mode

  Display brightness can be adjusted, follow procedure on 

9

.

 Require Wireless LAN connecting adapter which available as accessory.

Summary of Contents for 42TVAB010

Page 1: ...OWNER S MANUAL ENGLISH AIR CONDITIONER SPLIT TYPE For general public use Indoor unit 42TVAB010 013 018 024 028 030 033 Serise Outdoor unit 38TVAB010 013 018 024 028 030 033 1122350217...

Page 2: ...expose your body directly to cool or warm air for a long time Do not insert your finger or any article into the air inlet outlet When an abnormality burning smell etc occurs stop the air conditioner a...

Page 3: ...ppliance in kg h0 is the installation height of the appliance in m 0 6 m for floor standing 1 8 m for wall mounted 1 0 m for window mounted 2 2 m for ceiling mounted For these units recommend installa...

Page 4: ...tter Start Stop button Mode select button Temperature button Fan speed button Menu select button Set louver Up Down button Set louver Left Right button Check button Check button under battery cover 1...

Page 5: ...ure by press MENU button again When feature had selected will return to menu selection display triangle mark will blink 5 Leave from menu setting display by select exit and press menu button Leave fro...

Page 6: ...ing capacity and the Sound level of outdoor unit Compromising the Cooling capacity to the Sound level in any circumstance where the outdoor unit s sound level is highly prioritized This setting has a...

Page 7: ...by plasma ion contaminates such as bacteria odor smoke dust and virus are caught and deactivated by Plasma Ion 1 Press MENU button for enter menu setting and press TEMP button to select PURE This func...

Page 8: ...perature is 24 C and fan operation is automatic speed REMOTE CONTROL A B SELECTION 13 To separate using of remote control for each indoor unit in case of 2 air conditioners are installed nearly Remote...

Page 9: ...R32 3 8 TH...

Page 10: ...R32 Amin m2 Amin m2 Amin M 2 5 x 0 22759 x h0 2 M h0 0 6 1 8 1 0 2 2 2 5...

Page 11: ...2 3 4 1 2 3 4 5 6 7 8 9 5 6 7 1 1 3 4 5 2 1 Wi Fi 2 ECO 3 PURE 4 5 9 Wirelass LAN connecting adapter 1 2 17 C 30 C 3 AUTO LOW LOW MED MED HIGH Quiet 1 Auto A 2 17 C 30 C 3 AUTO LOW LOW MED MED HIGH Q...

Page 12: ...8 Hi power 8 1 H DA 1 MENU TEMP 2 MENU Louver set Setting feature 3 TEMP H DA 4 MENU 5 EXIT V H FIX H DA H DA H DA H DA...

Page 13: ...Two purpose 1 2 1 2 Faster cooling operation DRY and FAN ONLY 1 MENU HI POWER DRY and FAN ONLY 1 MENU 2 MENU 2 MENU 3 EXIT 3 EXIT 1 2 1 MENU 2 MENU 3 TEMP 4 MENU 5 EXIT 1 2 TEMP 8 3 Hi P 8 4 ECO 1 2 2...

Page 14: ...8 5 1 MENU 2 MENU 3 TEMP 0 5 12 4 MENU 5 EXIT 6 5 MENU TEMP 7 MENU 8 EXIT 8 7 8 6 PURE Odor 1 MENU TEMP PURE 100 75 50 POWER SELECTION 1 MENU TEMP 2 MENU 3 TEMP 100 75 50 2 MENU 3 EXIT 4 MENU 5 EXIT...

Page 15: ...ation Auto Restart Operation 3 3 Operation 5 5 AUTO RESTART ON 11 1 3 2 4 1 30 2 2 30 12 RESET AUTO 24 C A B 13 1 2 14 B 1 RESET 2 3 00 1 4 B 00 B 2 1 A 2 A A 3 A 1 3 3 ON 2 Cool 10 C 46 C 21 C 32 C D...

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...1122350217...