background image

GB - 10

42PQV...

X

DAILY timer 

 (Everyday - button J)

Push the button 

 when the ON or OFF timer is active. The icon

will appear on display. In this way the ON and OFF timer
memorization will be repeated every day. To disactivate the daily
function, press again the button 

.

Combination of ON, OFF and DAILY timer
procedure

If you want operation to start at 5.30 P.M. and stop at 10.30 P.M.,
proceed as follows:

1. 

Select ON timer at 5:30 P.M.

2. 

Select OFF timer at 10:30 P.M.

3. 

Select the desired operating mode (button 

).

If you want to stop operation at 10:30 P.M. and start again at
7:30 A.M. with the same operating mode, proceed as follows:

1. 

Select OFF timer at 10:30 P.M. during operation

2. 

Select ON timer at 7:30 A.M.

 If you want Everyday operation to start at 5.30 P.M. and stop at
10.30 P.M., proceed as follows:

1. 

Select ON timer at 5:30 P.M.

2. 

Select OFF timer at 10:30 P.M.

3. 

Press the Everyday button (daily button 

).

Cancellation of ON, OFF and DAILY timer
procedure

1.

If you want to cancel On or OFF timer
setting, press the following buttons in
sequence:

• button 

 or 

;

• button  .

To deactivate the Everyday function, press
button 

.

The Everyday function will remain operative
until one of the two timers (ON or
OFF) is active.

Use of the remote control

PM

PM

PM

AM

PM

PM

PM

Sleep timer procedure “night” 

  (button M)

Press this button to set the SLEEP timer with remote control on.
The icon will appear on the display.
This procedure permits setting the remaining unit operating time.

1.

“1:hr” will be displayed together with the
icon.

2.

Press button 

 (temperature increase).

The display will show the following
settings in sequence: 1 hr, 2 hr, 3 hr, 4
hr, 5 hr, 6 hr, 7 hr, 8hr and 9 hr.

3.

Once the remaining operating hours
have been selected with either button 
or 

, again press button 

 to confirm.

4.

When the SLEEP timer is set, the unit
will control the set temperature to avoid
overcooling or overheating during
operation. The set temperature will
change as follows:

PM

A

B

1

2

A

B

1

2

(Heating)

(Cooling only or dehumidification)

-1

°

C

°

C

30      90      150

-1

°

C

-1

°

C

SET

SET TIME

TIME

+0.5

°

C

+0.5

°

C

+0.5

°

C

+0.5

°

C

°

C

30      70      110    150

SET TIME

TIME

SET

Ionizer function button 

 (button N)

1.

Press Ionizer button 

  to activate

Ionizer function during unit ON.

2.

Press Ionizer button 

  again to stop

Ionizer function.

Address selector

If you have two indoor units in the same room, you can link one
remote control to one indoor unit, and the other remote control to
the other indoor unit, or you can control both indoor units with a
single remote control.

For configuration, refer to the installation manual.

Summary of Contents for 42PQV...X

Page 1: ...OWNER S MANUAL 42PQV X ...

Page 2: ... are contained in the relevant manuals The installation instructions for both the indoor and the outdoor unit are given in the manuals for each unit Contents Page General information 2 System description 2 Unit LEDs and controls 3 Periodical checks 3 Air cleaning system 4 Optimum comfort and minimum power consumption 4 Correct cleaning 4 5 Before a long shutdown period 5 Display of the selected fu...

Page 3: ...e control to avoid possible damage In case of malfunction contact a qualified service engineer This unit contains moving parts Ensure that these parts are kept out of the reach of children Maintain the room temperature at general comfort conditions especially when children elderly or handicapped persons are present In order to ensure correct use the air conditioner must operate within the temperat...

Page 4: ...gnal is received by the remote control the unit operates accordingly For a good operation of the air conditioner it is recommended to carry out checks and maintenance as indicated Recommended maintenance intervals may vary depending on the installation environment e g dusty zones etc 1 Increase frequency in dusty zones 2 Operations to be carried out by qualified service personnel Refer also to Ins...

Page 5: ...ontrol should only be cleaned with a dry cloth Occasionally clean the area around the outdoor leaves etc to avoid reduced air circulation Air cleaning system optimum comfort and lowest consumption correct cleaning Air cleaning system Standard air filters they eliminate dust and lint Electrostatic filter this effectively eliminates microscopic dust Active carbon filters they are particular effectiv...

Page 6: ...rts Switch the electric mains supply off Take the batteries out of the controller Clean indoor and outdoor units Filter cleaning Clean filters in accordance with the actual operating conditions and times Lift the front panel and pull the air filters downward Standard filter cleaning Vacuum clean or rinse under running water after using a month Put the filters back in the correct position Cleaning ...

Page 7: ...mer active 14 DAILY timer active Everyday 15 ON timer OFF timer and current time 16 OFF timer selected 17 Ionizer active WARNING During heat pump operation the unit will undergo several defrost cycles to remove ice that might collect on the outdoor unit in very low ambient temperatures In these cycles the indoor fan will be automatically off and cannot operate until defrost cycle is completed Tabl...

Page 8: ...st be directed toward the unit receiver when pressing the buttons of the desired functions An acoustical acknowledgement sound beep will indicate that signal has been received A B D E G H J K M N C F I L O A AM PM A B 1 2 F A AM PM A B 1 2 F The remote control operates with two 1 5 V non re chargeable batteries When the symbol appears in the display this indicates that the batteries are exhausted ...

Page 9: ...it a beep when the signals are received correctly PM A B 1 2 A B 1 2 Selection of the operating mode button A With this button the operating mode of the air conditioner can be selected By repeatedly pressing this button the available modes will be selected in sequence The choosen mode is shown as follows while the unit will acknowledge signal receipt with a confirming beep Indicated Symbol Ventila...

Page 10: ... for confirmation The icon will stop flashing 7 Louvre positioning Now this icon is flashing Use button to select desired position Press button for confirmation Now all icons are fixed on display If you want to cancel selections up to here inserted push button if you want to cancel all options once timer has been set push button and then About the ON timer When the ON Timer function is operating t...

Page 11: ...f the two timers ON or OFF is active Use of the remote control PM PM PM AM PM PM PM Sleep timer procedure night button M Press this button to set the SLEEP timer with remote control on The icon will appear on the display This procedure permits setting the remaining unit operating time 1 1 hr will be displayed together with the icon 2 Press button temperature increase The display will show the foll...

Page 12: ...to the unit receiver turn the remote control OFF and repeat the operation pointing the remote control in the correct direction There are obstacles curtains partitions etc between the remote control and the unit repeat the operation after having removed the obstacles The receiver on unit or the remote control is exposed to intense sun radiation avoid direct sunlight on the unit draw curtains or shu...

Page 13: ...Via R Sanzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice April 2006 Printed in Korea 42DH8C54020 R ...