background image

GB - 2

42PQV...

X

General information

Unit operation and maintenance

Read this instruction manual thoroughly before using the
unit.

• This unit complies with the low-voltage (EEC/73/23) and

electro-magnetic compatibility (EEC/89/336) directives.

• Check that the mains power supply has been connected to the

outdoor unit.

• Check that the mains power supply voltage and frequency are as

required for the unit; the power source must be sufficient to
operate all other appliances connected to the same line.

• All operation and maintenance manuals must be carefully looked

after and kept with the equipment, should the unit change
owners.

• Check that all current national safety code requirements for the

installation have been followed. In particular, ensure that a
properly sized and connected ground wire is in place.

• Only use the unit for factory approved applications: the unit

cannot be used in laundry premises.

• Do not use damaged equipment. In case of malfunction, turn the

unit OFF and disconnect the mains supply.

• Disconnect the mains power supply prior to any maintenance

operations or prior to handling any internal unit parts.

• The manufacturer declines any liability for damage resulting from

modifications or errors in the electrical or refrigerant connections,
made during the installation, or from improper use of this
equipment. This will invalidate the unit warranty conditions
immediately.

• This unit will only work safely and correctly, if installed and tested

by qualified personnel.

• Do not open the remote control to avoid possible damage.

In case of malfunction contact a qualified service engineer.

• This unit contains moving parts. Ensure that these parts are kept

out of the reach of children.

• Maintain the room temperature at general comfort conditions,

especially when children, elderly or handicapped persons are present.

• In order to ensure correct use, the air conditioner must operate

within the temperature limits indicated in the “Operating Limits”
table, included in the outdoor unit installation manual. Failure to
observe these limits may cause unit malfunction or water leakage.

• Inspect equipment for damage during transport. In case of

damage file an immediate claim with the shipping company.

• Non-routine maintenance of the refrigerant circuit must only be

carried out by qualified personnel.

• All of the manufacturing and packaging materials used for

this appliance are biodegradable and recyclable.

• Dispose of the packaging material and of the remote control

batteries in accordance with local requirements.

• This equipment contains refrigerant that must be disposed of

correctly. When disposing of the unit at the end of its operational
life, take the unit to an authorised waste disposal centre, or to the
original equipment dealer, for correct disposal procedures.

WARNING:
The unit must always be switched OFF using the remote
control. Do not switch OFF the split system by disconnecting
the electric power supply.

System description

A. Outdoor unit
B. Indoor unit
C. Remote Control (if foreseen)

1. Automatic swinging louvre
2. Air return
3. Air filters
4. Air outlet
5. Remote control signal receiver
6. Unit operating status indicators
7. Unit nameplate
8. Interconnecting tubing
9. Condensate drain

  

   

 

A

B

C

Summary of Contents for 42PQV...X

Page 1: ...OWNER S MANUAL 42PQV X ...

Page 2: ... are contained in the relevant manuals The installation instructions for both the indoor and the outdoor unit are given in the manuals for each unit Contents Page General information 2 System description 2 Unit LEDs and controls 3 Periodical checks 3 Air cleaning system 4 Optimum comfort and minimum power consumption 4 Correct cleaning 4 5 Before a long shutdown period 5 Display of the selected fu...

Page 3: ...e control to avoid possible damage In case of malfunction contact a qualified service engineer This unit contains moving parts Ensure that these parts are kept out of the reach of children Maintain the room temperature at general comfort conditions especially when children elderly or handicapped persons are present In order to ensure correct use the air conditioner must operate within the temperat...

Page 4: ...gnal is received by the remote control the unit operates accordingly For a good operation of the air conditioner it is recommended to carry out checks and maintenance as indicated Recommended maintenance intervals may vary depending on the installation environment e g dusty zones etc 1 Increase frequency in dusty zones 2 Operations to be carried out by qualified service personnel Refer also to Ins...

Page 5: ...ontrol should only be cleaned with a dry cloth Occasionally clean the area around the outdoor leaves etc to avoid reduced air circulation Air cleaning system optimum comfort and lowest consumption correct cleaning Air cleaning system Standard air filters they eliminate dust and lint Electrostatic filter this effectively eliminates microscopic dust Active carbon filters they are particular effectiv...

Page 6: ...rts Switch the electric mains supply off Take the batteries out of the controller Clean indoor and outdoor units Filter cleaning Clean filters in accordance with the actual operating conditions and times Lift the front panel and pull the air filters downward Standard filter cleaning Vacuum clean or rinse under running water after using a month Put the filters back in the correct position Cleaning ...

Page 7: ...mer active 14 DAILY timer active Everyday 15 ON timer OFF timer and current time 16 OFF timer selected 17 Ionizer active WARNING During heat pump operation the unit will undergo several defrost cycles to remove ice that might collect on the outdoor unit in very low ambient temperatures In these cycles the indoor fan will be automatically off and cannot operate until defrost cycle is completed Tabl...

Page 8: ...st be directed toward the unit receiver when pressing the buttons of the desired functions An acoustical acknowledgement sound beep will indicate that signal has been received A B D E G H J K M N C F I L O A AM PM A B 1 2 F A AM PM A B 1 2 F The remote control operates with two 1 5 V non re chargeable batteries When the symbol appears in the display this indicates that the batteries are exhausted ...

Page 9: ...it a beep when the signals are received correctly PM A B 1 2 A B 1 2 Selection of the operating mode button A With this button the operating mode of the air conditioner can be selected By repeatedly pressing this button the available modes will be selected in sequence The choosen mode is shown as follows while the unit will acknowledge signal receipt with a confirming beep Indicated Symbol Ventila...

Page 10: ... for confirmation The icon will stop flashing 7 Louvre positioning Now this icon is flashing Use button to select desired position Press button for confirmation Now all icons are fixed on display If you want to cancel selections up to here inserted push button if you want to cancel all options once timer has been set push button and then About the ON timer When the ON Timer function is operating t...

Page 11: ...f the two timers ON or OFF is active Use of the remote control PM PM PM AM PM PM PM Sleep timer procedure night button M Press this button to set the SLEEP timer with remote control on The icon will appear on the display This procedure permits setting the remaining unit operating time 1 1 hr will be displayed together with the icon 2 Press button temperature increase The display will show the foll...

Page 12: ...to the unit receiver turn the remote control OFF and repeat the operation pointing the remote control in the correct direction There are obstacles curtains partitions etc between the remote control and the unit repeat the operation after having removed the obstacles The receiver on unit or the remote control is exposed to intense sun radiation avoid direct sunlight on the unit draw curtains or shu...

Page 13: ...Via R Sanzio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice April 2006 Printed in Korea 42DH8C54020 R ...

Reviews: