Use of the remote controller

Start/stop
(button B)

When the air conditioner is not in operation, the controller readout
will display the time of day only (in case other symbols are lit, turn
controller off by pressing button B 

).

Press button B 

 to start the air conditioner; indicator N on the

unit will appear and be illuminated.
All selected and memorized functions will light up and appear; the
unit will operate according to the functions selected.
If the unit does not acknowledge the starting signal by emitting a
sound (“beep”) and indicator N does not light up, it is necessary to
turn the controller off by pressing button B 

 and then repeat the

operation.
Press button B 

 to stop the air conditioner.

All indicators on the unit will go out, and controller will display only
the current time.
If the unit does not stop, turn the controller on (by pressing button

) and repeat the operation.

In some special operating conditions the fan will continue to run
for 30 sec. after the unit stops; indicator P on the unit will lighten.
If button B 

 (air conditioner starting) is pressed too soon after a

stop, the compressor will not start for 3 minutes due to the
inherent protection against frequent compressor cycling; in this
case indicator P on the unit will also light up.
The unit will only emit a “beep”, when the signals are received
correctly.

Timer mode on/off
(button C)

Press this button if you want the air conditioner to operate in the
timer mode according to the time programs selected with button

.

If this function is on, indicator Q on the unit is lit.
After a power failure, indicator Q will flash and the unit will run in
the last operating condition before the power cut.
Power failures will deactivate the Timer mode: to reactivate the
Timer mode, press button C 

 twice.

Selection of the operating mode
(button D)

With this button the operating mode of the air conditioner can be
selected.
Different options are available depending on the unit model.
By repeatedly pressing this button the available modes will be
selected in sequence and the relevant symbols will appear on the
display, while the unit will acknowledge signal receipt with a
confirming beep.

Symbol on display

Cooling with dehumidification.

Heating (where available).

Automatic mode.
The air conditioner will automatically switch from heating
(where available) to cooling and vice versa in order to
maintain the selected temperature.

Dehumidification only.
The air conditioner extracts moisture from the air without
sensibly changing the room temperature.

Ventilation (fan only).

Setting desired temperature

UP
(button E)

DOWN
(button F)

Pressing the UP (E 

) and DOWN (F 

) buttons will increase or

decrease the temperature set from the previously set value. The
unit will confirm signal receipt with a beep, and the value of the set
temperature on the display will change accordingly.
The temperature can be set between 18

°

C and 29

°

C at 1 degree

intervals.
In the cooling mode, if the temperature selected is higher than the
room temperature, the unit will not start; the same applies for the
heating mode, if the selected temperature is lower than the room
temperature.

Setting the timer programs
(button G)

By pressing button G 

 it is possible to choose one of the

following programs in sequence:

Symbol on display

No symbol

Continuous operation (timer off)

Start time program
Stop time program

Combined program: unit will automatically cycle on and off
as programmed

 Set start time

Press button G 

 until the symbol  indicating unit start program

appears on the display under the word TIMER.
• The time appearing on display shows the starting hour
  previously programmed:

• You can set your personalized new start time by pressing buttons

 and I 

 until the desired time appears. Each press of the

button will change the time up or down by 15 min. between 0:00
and 23:45.
Press button C 

 to confirm your selection: indicator Q on the

unit will light up and the air conditioner is ready to start at the
selected time. If the unit is in operation when you send your
confirmation by pressing button C 

, it will turn off and

restart at the time now programmed.

 Set stop time

Press button G 

 until the symbol indicating the unit stop program

appears on the display under the word TIMER.
The time appearing on the display shows the stop time previously
programmed; you can now set your personalized new stop time by
proceeding as for the start time.
If the unit is turned off when you send your program confirmation by
pressing button C 

, it will start up, and then turn off at the time

now programmed.

Summary of Contents for 42 VKG

Page 1: ...42 VKG Console T h e S t andards Institutiono f I s r a e l Q u ality Assured Fi r m SI ISO 9001 OWNER S MANUAL...

Page 2: ...the present manual Remote control instructions are contained in the relevant manuals supplied with the remote controls The installation instructions for both the indoor and the outdoor unit are given...

Page 3: ...tly if installed and tested by qualified personnel Do not open the electronic remote controller to avoid possible damage In case of malfunction contact a qualified service engineer This unit contains...

Page 4: ...ndoor unit 1 Receiver of signals from remote controller 2 Indicators of unit operating status 3 Louvre 4 Air return 5 Air filters 6 Air outlet 7 Characteristics nameplate 8 Interconnecting tubing 9 Co...

Page 5: ...gement sound beep will indicate that signal has been received If the signal has not been received renewed transmission is necessary by pressing any of the buttons E F L or J situated under the sliding...

Page 6: ...rips the circuit contact your local Assistance centre During heat pump operation unit will undergo several defrost cycles to eliminate ice that might possibly collect on the outdoor unit in very low a...

Page 7: ...the remote controller For correct maintenance of the air conditioner contact an authorized service centre Table II Periodical checks S N P Q R Indoor unit Clean air filter Clean drain pipe Change cont...

Page 8: ...g beep Symbol on display Cooling with dehumidification Heating where available Automatic mode The air conditioner will automatically switch from heating where available to cooling and vice versa in or...

Page 9: ...p times will start and stop the air conditioner daily at the programmed time without any action from the user To program this function proceed as follows 1 Press button G until the symbol of the start...

Page 10: ...he unit in operation for half a day in the ventilation fan only mode in order to dry all its internal parts Switch electric mains supply off Take batteries out of the controller Clean indoor and outdo...

Page 11: ...e them approximately every five years Ensure a uniform air circulation in the room controlling the air flow direction in the appropriate way Maintenance Before restarting the unit after prolonged shut...

Page 12: ...There are obstacles curtains walls etc between the controller and the unit repeat the operation after having removed the obstacles Receiver on the unit or the remote controller is under intense sun r...

Page 13: ...zio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice Order No 14278 74 February 2001 Supersedes Order No 14278 74 Janu...

Reviews: