Troubleshooting

After batteries have been placed into the controller, the
display is not lit:
• Batteries are exhausted or have the wrong polarity; replace

batteries or check polarity.

When pressing the recessed clock adjustment button, hour
figures on display do not flash:
• 
Recessed button has not been pressed correctly; press with a

round point, avoid exerting strong pressure.

When pressing any button all symbols appear on display:
• 
Recessed button for time setting is blocked due to excessive

pressure during use.
Controller has been irreversibly damaged; replace with a new one.

When pressing the start button, unit does not start and does
not acknowledge signal with a beep:
• 
Main switch is OFF, switch it to ON.
• Controller batteries are exhausted; replace.
• Controller has not been pointed correctly to the unit receiver;

turn controller off and repeat the operation in the correct
direction.

• There are obstacles (curtains, walls, etc.) between the controller

and the unit; repeat the operation after having removed  the
obstacles.

• Receiver on the unit or the remote controller is under intense sun

radiation; avoid direct sun on the unit, shut curtains or shades.

• Signal transmission is obstructed by severe interference from an

electromagnetic field; avoid sending signals when computers or
household appliances (food processors, coffee grinders, etc.) are
operating close by.
Cellular or cordless telephones may also interfere with the
control.

When pressing the stop button unit does not turn off and
does not acknowledge signal with a beep:
• Controller batteries are exhausted; replace.
• Controller has not been pointed correctly to the unit receiver;

turn controller off and repeat the operation in the correct
direction.

• There are obstacles (curtains, walls, etc.) between the controller

and the unit; repeat the operation after having removed  the
obstacles.

• Receiver on the unit or the remote controller is under intense sun

radiation; avoid direct sun on the unit, shut curtains or shades.

• Signal transmission is obstructed by severe interference from an

electromagnetic field; avoid sending signals when computers or
household appliances (food processors, coffee grinders, etc.) are
operating close by.
Cellular or cordless telephones may also interfere with the control.

When pressing the stop button the unit acknowledges signal
receipt with a beep, but fan will not stop

 

and indicator P is on:

• Unit will stop after 30 sec.

When pressing any function button, controller shows the
function requested on the display, but unit does not
acknowledge signal receipt with a beep and does not carry
out  the function:
• Controller batteries are exhausted; replace.
• Controller has not been pointed correctly to the unit receiver; turn

controller off and repeat the operation in the correct direction.

• There are obstacles (curtains, walls, etc.) between the controller

and the unit; repeat the operation after having removed the
obstacles.

• Receiver on the unit or the remote controller is under intense sun

radiation; avoid direct sun on the unit, shut curtains or shades.

• Signal transmission is obstructed by severe interference from an

electromagnetic field; avoid sending signals when computers or
household appliances (food processors, coffee grinders, etc.) are
operating close by. Cellular or cordless telephones may also
interfere with the control.

When pressing any button display will not change:
• The triangle symbol 1

 is on, as another signal is being

transmitted; wait for signal 1

 to disappear and repeat the

operation.

Air conditioner will not start:
• Main supply switch is OFF; switch to ON.
• Fuses on main switch are blown; replace fuses.
• Wait for 3 minutes: protection against frequent compressor cycling

is on if the symbol P is lit.

• Selected temperature is higher than the room temperature (or

lower in the heating mode).

Air conditioner is not supplying enough cooling (or heating):
• Air flow cannot circulate freely.
• Dirty filters reduce air quantity circulating.
• Doors and/or windows are open.
• Fan speed has been set to 'low'.
• Air flow direction is not correct.
• Selected temperature is not correct.

A slight mist is emitted from the unit:
• A slight mist, coming out of the unit air outlet, can sometimes be

noticed during cooling operation. This is due to the cool air coming
into contact with the room air.

A slight whistling noise is heard when the air conditioner
starts or stops:
• This is due to the refrigerant beginning to circulate or an

adjustment of the refrigerant pressures.

R indicator is flashing:
System malfunction.
Contact service organization after having made the following
checks:
• Filters are clean.
• Air circulation is not obstructed.
• Outdoor unit coil is not obstructed with a severe reduction of air

circulation.

Restart air conditioner after having corrected the faults.

Water vapour (mist) emanating from the outdoor unit:
• It is normal in heat pump operation, when defrost is automatically

activated.

Unpleasant smells coming from the unit:
• Unpleasant smells can be caused by substances accumulated in

the air filter.
Switch the unit off and contact an authorised service centre to
have the filters cleaned.
Restart unit in the ventilation (fan only) mode and open windows
to change room air.

Strange noises coming from the unit:
• Occasionally the unit can emit some strange short noises during

operation or when it has stopped.
These are generally due to the effect of temperature changes on
the plastic parts.

Starting in heating mode for heat pump systems:
• If the unit starts at low ambient temperatures, it takes a little

while to reach a comfortable room temperature.
When the unit is started by the remote control, it emits a signal
beep, but the louvre does not swing and the fan does not run
until the operating temperature has been reached. During this
period the P indicator light is on.

Summary of Contents for 42 VKG

Page 1: ...42 VKG Console T h e S t andards Institutiono f I s r a e l Q u ality Assured Fi r m SI ISO 9001 OWNER S MANUAL...

Page 2: ...the present manual Remote control instructions are contained in the relevant manuals supplied with the remote controls The installation instructions for both the indoor and the outdoor unit are given...

Page 3: ...tly if installed and tested by qualified personnel Do not open the electronic remote controller to avoid possible damage In case of malfunction contact a qualified service engineer This unit contains...

Page 4: ...ndoor unit 1 Receiver of signals from remote controller 2 Indicators of unit operating status 3 Louvre 4 Air return 5 Air filters 6 Air outlet 7 Characteristics nameplate 8 Interconnecting tubing 9 Co...

Page 5: ...gement sound beep will indicate that signal has been received If the signal has not been received renewed transmission is necessary by pressing any of the buttons E F L or J situated under the sliding...

Page 6: ...rips the circuit contact your local Assistance centre During heat pump operation unit will undergo several defrost cycles to eliminate ice that might possibly collect on the outdoor unit in very low a...

Page 7: ...the remote controller For correct maintenance of the air conditioner contact an authorized service centre Table II Periodical checks S N P Q R Indoor unit Clean air filter Clean drain pipe Change cont...

Page 8: ...g beep Symbol on display Cooling with dehumidification Heating where available Automatic mode The air conditioner will automatically switch from heating where available to cooling and vice versa in or...

Page 9: ...p times will start and stop the air conditioner daily at the programmed time without any action from the user To program this function proceed as follows 1 Press button G until the symbol of the start...

Page 10: ...he unit in operation for half a day in the ventilation fan only mode in order to dry all its internal parts Switch electric mains supply off Take batteries out of the controller Clean indoor and outdo...

Page 11: ...e them approximately every five years Ensure a uniform air circulation in the room controlling the air flow direction in the appropriate way Maintenance Before restarting the unit after prolonged shut...

Page 12: ...There are obstacles curtains walls etc between the controller and the unit repeat the operation after having removed the obstacles Receiver on the unit or the remote controller is under intense sun r...

Page 13: ...zio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice Order No 14278 74 February 2001 Supersedes Order No 14278 74 Janu...

Reviews: