42 VKG

GB - 8

Night stop
(button K)

This function optimizes comfort at night with regard to human
metabolism variations.
One hour after activation of this function, the temperature set in
cooling will increase by 1

°

C, or decrease by 1

°

C if in heating, up

to 2

°

C in two hours. After 5 hours the unit will stop completely.

The system will operate at the low fan speed to minimize the
sound level. When activating this function, the controller will show
the time when the air conditioner will completely stop for a few
seconds.
Press button C 

 to deactivate the function.

Adjusting clock time
(button M)

To adjust the clock time, put the controller in the ON position by
pressing button B 

 after having inserted the batteries.

The following procedure will allow adjustment of the clock time:

• Gently press the recessed button at the right corner of the

controller battery compartment with a pointed tool (e.g. a pencil
point): the hour figures will flash.
Use buttons H 

 and I 

 to adjust their value to the correct time

of day.

• Press the recessed button a second time and the minute figures

will flash. Adjust them to the correct value in the same way.

• Pressing the recessed button a third time will activate the clock

function.

Supply air guide vane positioning
(button L)

To optimise the air distribution in the room, the air flow direction can
be varied.
Repeatedly press button L    to select one of the guide vane
positions shown below.

Symbol on display

    

Automatic
The air flow direction is automatically controlled.
In the cooling mode the guide vane position directs the air
flow closely along the ceiling; in the heating mode however,
the guide vane position is set to direct the air flow towards
the floor, to prevent hot air layers in the upper part of the
room.

Six selectable positions.
It is possible to position the guide vanes at
six different angles to direct the air flow.
Positions 

 and 

 are recommended for

the cooling mode.
Positions 

 and 

 

are recommended for

the heating mode.
Position 

 prevents cold air draughts in

ceiling installations in cooling mode.

Swing function
The guide vanes move continuously from top to bottom and
vice versa to allow improved air distribution.

Use of the remote controller

 Set combined program

The combined program (a selection of a sequence of start and
stop times) will start and stop the air conditioner daily at the
programmed time without any action from the user.

To program this function proceed as follows:

1. Press button G 

 until the symbol of the start time program

shows on the display;  set now your desired start time in the
way indicated in the “set start time” section.

2. Press button G 

 

again to show the symbol for the stop time

program and set your desired stop time.

3. Press button G 

 repeatedly, until the symbol for the combined

program  appears; together with this symbol, the symbols for
the start and stop programs appear alternatively along with the
respective programmed times.

4. To confirm the program, press button C 

. Indicator Q on the

unit will light up.

If the programmed times for start and stop coincide, the combined
operation mode will not work.
It is possible to cancel the TIMER operation mode at any time by
pressing button C 

: indicator Q on the unit will turn off, and the

indication of the timer mode will disappear from the display on the
controller.
The unit will store the mode in which was operating at that time:
on if it was in operation, off if it was turned off.

When the timer mode is on (unit indicator Q lit) the controller will
always display the symbol relevant to the current timer program;
the time shown is the current time of day.

When only one of the two programs has been selected, i.e. the
start time or the stop time, the unit will remain in the selected
operating mode (on or off) after having turned on or off at the
selected time. To change the operating mode, it is necessary to
manually start or stop the unit or select a new program by
pressing button C 

.

In case of a power failure during timer mode operation, the unit
will restart, when the power is restored and return to the last
operating position before the power cut: unit indicator Q will flash
to show that the timer mode is off. To reactivate the timer mode,
press button C 

 twice.

Time adjustment
(buttons H and I)

To set the time for the timer programs selected with button G 

,

press the buttons H 

 and I 

 . Buttons H 

 and I 

  also

serve to adjust the time of day on the display under the word
CLOCK.

Selecting the fan speed
(button J)

The fan speed can be selected by pressing button J 

 .

 Symbol on display

 

Low speed
(for night and normal operation)

High speed
(at start-up, to reach temperature)

Automatic
(Fan speed will automatically switch to the value
required for optimum comfort).
When this function is activated, the dotted symbols
will flash.

Summary of Contents for 42 VKG

Page 1: ...42 VKG Console T h e S t andards Institutiono f I s r a e l Q u ality Assured Fi r m SI ISO 9001 OWNER S MANUAL...

Page 2: ...the present manual Remote control instructions are contained in the relevant manuals supplied with the remote controls The installation instructions for both the indoor and the outdoor unit are given...

Page 3: ...tly if installed and tested by qualified personnel Do not open the electronic remote controller to avoid possible damage In case of malfunction contact a qualified service engineer This unit contains...

Page 4: ...ndoor unit 1 Receiver of signals from remote controller 2 Indicators of unit operating status 3 Louvre 4 Air return 5 Air filters 6 Air outlet 7 Characteristics nameplate 8 Interconnecting tubing 9 Co...

Page 5: ...gement sound beep will indicate that signal has been received If the signal has not been received renewed transmission is necessary by pressing any of the buttons E F L or J situated under the sliding...

Page 6: ...rips the circuit contact your local Assistance centre During heat pump operation unit will undergo several defrost cycles to eliminate ice that might possibly collect on the outdoor unit in very low a...

Page 7: ...the remote controller For correct maintenance of the air conditioner contact an authorized service centre Table II Periodical checks S N P Q R Indoor unit Clean air filter Clean drain pipe Change cont...

Page 8: ...g beep Symbol on display Cooling with dehumidification Heating where available Automatic mode The air conditioner will automatically switch from heating where available to cooling and vice versa in or...

Page 9: ...p times will start and stop the air conditioner daily at the programmed time without any action from the user To program this function proceed as follows 1 Press button G until the symbol of the start...

Page 10: ...he unit in operation for half a day in the ventilation fan only mode in order to dry all its internal parts Switch electric mains supply off Take batteries out of the controller Clean indoor and outdo...

Page 11: ...e them approximately every five years Ensure a uniform air circulation in the room controlling the air flow direction in the appropriate way Maintenance Before restarting the unit after prolonged shut...

Page 12: ...There are obstacles curtains walls etc between the controller and the unit repeat the operation after having removed the obstacles Receiver on the unit or the remote controller is under intense sun r...

Page 13: ...zio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice Order No 14278 74 February 2001 Supersedes Order No 14278 74 Janu...

Reviews: