OWNER’S MANUAL

Summary of Contents for 42 VKG

Page 1: ...42 VKG Console T h e S t andards Institutiono f I s r a e l Q u ality Assured Fi r m SI ISO 9001 OWNER S MANUAL...

Page 2: ...the present manual Remote control instructions are contained in the relevant manuals supplied with the remote controls The installation instructions for both the indoor and the outdoor unit are given...

Page 3: ...tly if installed and tested by qualified personnel Do not open the electronic remote controller to avoid possible damage In case of malfunction contact a qualified service engineer This unit contains...

Page 4: ...ndoor unit 1 Receiver of signals from remote controller 2 Indicators of unit operating status 3 Louvre 4 Air return 5 Air filters 6 Air outlet 7 Characteristics nameplate 8 Interconnecting tubing 9 Co...

Page 5: ...gement sound beep will indicate that signal has been received If the signal has not been received renewed transmission is necessary by pressing any of the buttons E F L or J situated under the sliding...

Page 6: ...rips the circuit contact your local Assistance centre During heat pump operation unit will undergo several defrost cycles to eliminate ice that might possibly collect on the outdoor unit in very low a...

Page 7: ...the remote controller For correct maintenance of the air conditioner contact an authorized service centre Table II Periodical checks S N P Q R Indoor unit Clean air filter Clean drain pipe Change cont...

Page 8: ...g beep Symbol on display Cooling with dehumidification Heating where available Automatic mode The air conditioner will automatically switch from heating where available to cooling and vice versa in or...

Page 9: ...p times will start and stop the air conditioner daily at the programmed time without any action from the user To program this function proceed as follows 1 Press button G until the symbol of the start...

Page 10: ...he unit in operation for half a day in the ventilation fan only mode in order to dry all its internal parts Switch electric mains supply off Take batteries out of the controller Clean indoor and outdo...

Page 11: ...e them approximately every five years Ensure a uniform air circulation in the room controlling the air flow direction in the appropriate way Maintenance Before restarting the unit after prolonged shut...

Page 12: ...There are obstacles curtains walls etc between the controller and the unit repeat the operation after having removed the obstacles Receiver on the unit or the remote controller is under intense sun r...

Page 13: ...zio 9 20058 Villasanta MI Italy Tel 039 3636 1 The manufacturer reserves the right to change any product specifications without notice Order No 14278 74 February 2001 Supersedes Order No 14278 74 Janu...