background image

4

INSTALLING RTX ROOM DISPLAY

The RTX display unit must be fixed to the wall. Do not locate the

RTX display unit underneath the indoor unit (see Fig. 10).

A06449

A06480

Fig. 10

 − 

RTX Room Display

1. Remove the RTX display unit from its packaging.
2. Place the unit on the wall, taking into account the length

of available cable.

3. Connect the display unit cable to the RTX display unit

(see Fig. 8).

4. Connect the air

conditioner to the power supply and make

an initial check to ensure that everything is working

properly.

5. Check that the RTX display unit light is ON.
6. Press the ON button to start the air

conditioner working.

7. If the air

conditioner does not begin working, or is not

working properly, refer to the Troubleshooting section.

8. If the air

conditioner is working properly, turn it OFF and

disconnect it from the power supply.

9. Remove the cover from the RTX display unit (see Fig.

11).

10. Use the template to mark the position for drilling the hole

for the screw.

11. Press an anchor into the hole in the wall.
12. Use the screw to attach the RTX display unit onto the wall

(see Fig. 11).

DISPLAY CABLE

RTX

RTX

Display Control Card

(New in the controller)

Remove the

display unit

cover

Screw to

fix unit

to wall

ON Button

Power ON

Light

Display

2.8 meters

(9.2 ft)

RTX Display Unit

Insert the

display cable

into the RTX

display unit

A06481

Fig. 11

 − 

Connecting Display Unit Cable to RTX

                  TESTING AND TROUBLESHOOTING

1. If the RTX room display unit is working properly during

the initial check, perform a complete check as instructed in

the attached operating manual. Check the changes between

operating modes, changes in fan speed settings,

temperature adjustments, etc.

2. If necessary, the display can be changed from degrees

Celsius to degrees Fahrenheit (details in the operating

manual).

3. If the complete check reveals any malfunctions, refer to

the troubleshooting table in the operating manual.

4. If the air

conditioner is working properly, turn it OFF and

disconnect it from the power supply.

5. Refer to the section in this manual marked 

Installation of

Display Adapter Card 

and reverse steps 5 through 11.

6. Connect the air

conditioner to the power supply.

7. Turn the air

conditioner ON.

Table 2—Troubleshooting Table

Malfunction

Possible Causes

Recommended Solutions

RTX Display Unit is not lit (display OFF)
and the POWER indicator light is OFF

Faulty display unit cable (cable between the
control box and the RTX room display unit).

RTX room display unit malfunctioning.

Replace the display unit cable.

Replace the RTX room display unit.

RTX Display Unit is not lit (display OFF)
and the POWER indicator light is ON.
A beep can be heard every 20 seconds.

Faulty display unit cable (cable between the
control box and the RTX room display unit).

Dipswitches are not set properly.

Replace the display unit cable.

Check position of dipswitches according to
the sticker on the side of the control.

Dipswitch 4 should be in the OFF position.

Copyright 2006 CAC / BDP 

S

  7310 W. Morris St. 

S

  Indianapolis, IN  46231

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Catalog  No: IIK−53DS900−5

    Replaces: New

Printed in U.S.A.

Edition Date: 08/06

53DS

900

−−−

091

Summary of Contents for 40BNC

Page 1: ...in personal injury or death Before beginning any modification or installation of this kit be sure the main electrical disconnect is in the OFF position Ensure power is disconnected to the fan coil unit On some systems both the fan coil and the outdoor unit may be on the same disconnect Tag the disconnect switch with a suitable warning label There may be more than one disconnect WARNING GENERAL The...

Page 2: ... Ensure power is disconnected to the fan coil unit On some systems both the fan coil and the outdoor unit may be on the same disconnect Tag the disconnect switch with a suitable warning label There may be more than one disconnect WARNING 5 Remove the front grille see Fig 3 A06470 Fig 3 Remove Front Grille 6 Carefully close the louvers 7 Remove the two screws from the electrical box cover See Fig 4...

Page 3: ...tor to its original location Additional display card connection previously hidden A06475 Fig 8 Threading Display Cable 22 Insert the end of the new display unit cable into the socket located underneath the wall control adapter circuit board see Fig 8 23 Insert the ends of the two wiring harnesses into the existing connectors located in upper part of the Display Adapter Card see Fig 8 24 Press down...

Page 4: ...mplete check as instructed in the attached operating manual Check the changes between operating modes changes in fan speed settings temperatureadjustments etc 2 If necessary the display can be changed from degrees Celsius to degrees Fahrenheit details in the operating manual 3 If the complete check reveals any malfunctions refer to the troubleshooting table in the operating manual 4 If the air con...

Reviews: