Manual Operation 

Care and Maintenance

3     

Ca

re and 

Maintenance

Cleaning Your Air Filter

A clogged air conditioner can reduce the cooling 

efficiency of your unit, and can also be bad for 

your health. Make sure to clean the filter once 

every two weeks.
1.  Lift the front panel of the indoor unit. Use

suspension bar to prop up the panel.

2.  Grip the tab on the end of the filter, lift it

up,then   pull it towards yourself.

3.  Now pull the filter  out.
4.  If your filter has a small air freshening filter, 

unclip it from the larger filter. Clean this air 

freshening filter with a hand-held vacuum.

5.  Clean the large air filter with warm, soapy 

water. Be sure to use a mild detergent.

6. 

Rinse the filter with fresh water, then shake 

off excess water.

7. 

Dry it in a cool, dry place, and refrain from 

exposing it to direct sunlight.

8. 

When dry, re-clip the air freshening filter to 

the larger filter, then slide it back into the 

indoor unit.

9. 

Close the front panel of the indoor unit.

Filter Tabs

Remove air freshening 

f

ilter from back of 

larger filter (some units)

Cleaning Your Indoor Unit

 BEFORE CLEANING OR

 

 MAINTENANCE

ALWAYS TURN OFF YOUR AIR CONDITIONER
SYSTEM AND DISCONNECT ITS POWER SUPPLY
BEFORE CLEANING OR MAINTENANCE.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 CAUTION

Only use a soft, dry cloth to wipe the unit clean. 

If the unit is especially dirty, you can use a cloth 

soaked in warm water to wipe it clean.

• 

Do not

 

use chemicals or chemically treated 

cloths to clean the unit

• 

Do not 

use benzene, paint thinner, 

polishing powder or other solvents to clean 

the unit. They can cause the plastic surface 

to crack or deform.

• 

Do not

 use water hotter than 40°C (104°F) 

to clean the front panel. This can cause the 

panel to deform or become discolored.

 CAUTION

Do not touch air freshening (Plasma) filter for 

at least 10 minutes after turning off the unit.

Summary of Contents for 38QHB026N8

Page 1: ...SPLIT TYPE AIR CONDITIONER OWNER S MANUAL MODEL 42QHB026N8 38QHB026N8 42QHB035N8 38QHB035N8 42QHB050N8 38QHB050N8 42QHB070N8 38QHB070N8 42QHB090N8 38QHB090N8...

Page 2: ...the following options Dispose of the appliance at designated municipal electronic waste collection facility When buying a new appliance the retailer will take back the old appliance free of charge Th...

Page 3: ...lved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision EN Standard requirements WARNINGS FOR PRODUCT USE If an abnormal situati...

Page 4: ...indows open or if the humidity is very high Note about Fluorinated Gasses 1 This air conditioning unit contains fluorinated greenhouse gasses For specific information on the type of gas and the amount...

Page 5: ...operation mode some units Under COOL and DRY mode it displays as cool colour Under HEAT mode it displays as warm colour when Wireless Control feature is activated some units for 3 seconds when TIMER...

Page 6: ...dicators describing below are available for the air conditioner you purchased Please check the indoor display window of the unit you purchased for 3 seconds when TIMER ON is set FRESH SWING TURBO SILE...

Page 7: ...when you are ready to go to sleep When in COOL mode the unit will increase the temperature by 1 C 2 F after 1 hour and will increase an additional 1 C 2 F after another hour When in HEAT mode the uni...

Page 8: ...p cooling systems To further optimize the performance of your unit do the following Keep doors and windows closed Limit energy usage by using TIMER ON and TIMER OFF functions Do not block air inlets o...

Page 9: ...ers in or near the blower and suction side of the unit The high speed fan inside the unit may cause injury Fig B Fig A Setting Angle of Air Flow Setting horizontal angle of air flow To operate your un...

Page 10: ...to direct sunlight 8 When dry re clip the air freshening filter to the larger filter then slide it back into the indoor unit 9 Close the front panel of the indoor unit Filter Tabs Remove air fresheni...

Page 11: ...ng Periods of Non Use If you plan not to use your air conditioner for an extended period of time do the following Clean all filters Turn on FAN function until unit dries out completely Turn off the un...

Page 12: ...emperature fluctuates again The indoor unit emits white mist In humid regions a large temperature difference between the room s air and the conditioned air can cause white mist Both the indoor and out...

Page 13: ...nt operating mode Dust is emitted from either the indoor or outdoor unit The unit may accumulate dust during extended periods of non use which will be emitted when the unit is turned on This can be mi...

Page 14: ...or outlet of either unit is blocked Turn the unit off remove the obstruction and turn it back on Doors and windows are open Make sure that all doors and windows are closed while operating the unit Exc...

Page 15: ...anostat to regulate the voltage Poor heating performance The outdoor temperature is extremely low Use auxiliary heating device Cold air is entering through doors and windows Make sure that all doors a...

Page 16: ...pdates to the manual will be uploaded to the service website please check product improvement Consult with the sales agency or manufacturer for details The design and specifications are subject to cha...

Reviews: