Tr

oubleshooting

Problem

Possible Causes

Solution

The unit is not 

working

Power failure

Wait for the power to be 

restored

The power is turned off

Turn on the power

The fuse is burned out

Replace the fuse

Remote control batteries are 

dead

Replace batteries

The Unit’s 3-minute protection 

has been activated

Wait three minutes after 

restarting the unit

Timer is activated

Turn timer off

The unit starts and 

stops frequently

There’s too much or too little 

refrigerant in the system

Check for leaks and 

recharge the system with 

refrigerant.

Incompressible gas or 

moisture has entered the 

system.

Evacuate and recharge the 

system with refrigerant

The compressor is broken Replace the compressor

The voltage is too high or 

too low

Install a manostat to 

regulate the voltage

Poor heating 

performance

The outdoor temperature is 

extremely low

Use auxiliary heating 

device

Cold air is entering through 

doors and windows

Make sure that all doors 

and windows are closed 

during use

Low refrigerant due to leak or 

long-term use

Check for leaks, re-seal 

if necessary and top off 

refrigerant

Indicator lamps 

continue flashing

The unit may stop operation or continue to run safely. If 

the indicator lamps continue to flash or error codes appear, 

wait for about 10 minutes. The problem may resolve itself. 
If not, disconnect the power, then connect it again. Turn 

the unit on.
If the problem persists, disconnect the power and contact 

your nearest customer service center.

Error code appears in 

the window display 

of indoor unit:

• 

E0, E1, E2…

• 

P1, P2, P3…

• 

F1, F2, F3…

NOTE:

 If your problem persists after performing the checks and diagnostics above, 
 turn off your unit immediately and contact an authorized service center.  

Summary of Contents for 38QHB026N8

Page 1: ...SPLIT TYPE AIR CONDITIONER OWNER S MANUAL MODEL 42QHB026N8 38QHB026N8 42QHB035N8 38QHB035N8 42QHB050N8 38QHB050N8 42QHB070N8 38QHB070N8 42QHB090N8 38QHB090N8...

Page 2: ...the following options Dispose of the appliance at designated municipal electronic waste collection facility When buying a new appliance the retailer will take back the old appliance free of charge Th...

Page 3: ...lved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision EN Standard requirements WARNINGS FOR PRODUCT USE If an abnormal situati...

Page 4: ...indows open or if the humidity is very high Note about Fluorinated Gasses 1 This air conditioning unit contains fluorinated greenhouse gasses For specific information on the type of gas and the amount...

Page 5: ...operation mode some units Under COOL and DRY mode it displays as cool colour Under HEAT mode it displays as warm colour when Wireless Control feature is activated some units for 3 seconds when TIMER...

Page 6: ...dicators describing below are available for the air conditioner you purchased Please check the indoor display window of the unit you purchased for 3 seconds when TIMER ON is set FRESH SWING TURBO SILE...

Page 7: ...when you are ready to go to sleep When in COOL mode the unit will increase the temperature by 1 C 2 F after 1 hour and will increase an additional 1 C 2 F after another hour When in HEAT mode the uni...

Page 8: ...p cooling systems To further optimize the performance of your unit do the following Keep doors and windows closed Limit energy usage by using TIMER ON and TIMER OFF functions Do not block air inlets o...

Page 9: ...ers in or near the blower and suction side of the unit The high speed fan inside the unit may cause injury Fig B Fig A Setting Angle of Air Flow Setting horizontal angle of air flow To operate your un...

Page 10: ...to direct sunlight 8 When dry re clip the air freshening filter to the larger filter then slide it back into the indoor unit 9 Close the front panel of the indoor unit Filter Tabs Remove air fresheni...

Page 11: ...ng Periods of Non Use If you plan not to use your air conditioner for an extended period of time do the following Clean all filters Turn on FAN function until unit dries out completely Turn off the un...

Page 12: ...emperature fluctuates again The indoor unit emits white mist In humid regions a large temperature difference between the room s air and the conditioned air can cause white mist Both the indoor and out...

Page 13: ...nt operating mode Dust is emitted from either the indoor or outdoor unit The unit may accumulate dust during extended periods of non use which will be emitted when the unit is turned on This can be mi...

Page 14: ...or outlet of either unit is blocked Turn the unit off remove the obstruction and turn it back on Doors and windows are open Make sure that all doors and windows are closed while operating the unit Exc...

Page 15: ...anostat to regulate the voltage Poor heating performance The outdoor temperature is extremely low Use auxiliary heating device Cold air is entering through doors and windows Make sure that all doors a...

Page 16: ...pdates to the manual will be uploaded to the service website please check product improvement Consult with the sales agency or manufacturer for details The design and specifications are subject to cha...

Reviews: