14. Short Timer
In the normal condition, after switching one circuit
breaker, 3-minute delay time for compressor and
1 hour for plasma air purifier are set for the
maintenance of the unit.
Purpose
To start the unit immediately for the purpose of
testing, trial...etc, short timer can be used.
maintenance of the unit.
Short Timer Setting
purifier on the remote control without
[CHK] button and hold, "00" will show
to make "00" disappear.
setting on the remote operates
front panel turns ON continuously for
j
Press [ ] button to turn the unit OFF.
k
Set the operation mode or plasma air
sending the signal to the unit.
l
Use the tip of the pencil to push the
on display, them press [
] button
m
Press [ ] button to turn the unit ON.
n
When short timer is activated, all
immediately, besides, all indicatiors on
3
seconds.
−
38
−
ON
OFF
•
„
ƒ
15. Hi-POWER
([Hi-POWER] button on the remote controller
is pressed)
When [Hi-POWER]
button is pressed while the
indoor
unit is in Auto, Cooling or Heating operation, Hi-
Mode
POWER mark is indicated on the display of the remote
controller and the unit operates as follows.
1. Automatic operation
•
The indoor unit operates in according to the
current operation.
2. Cooling operation
remote controller does not change.)
The indoor unit's fan speed level increase 1 tap
•
The preset temperature drops 1 degree
(The value of the preset temperature on the
3. Heating operation
remote controller does not change.)
The indoor unit's fan speed level increase 1 tap
•
The preset temperature increases 2 degree
(The value of the preset temperature on the
4. The Hi-POWER mode can not be set in Dry
operation