38
Outdoor Fan Motor
Model: YDK24-6G
Measure the resistance value of each winding by using the multi-meter.
Model: YDK50-6C
Measure the resistance value of each winding by using the multi-meter.
Indoor Fan Motor
Model: RPG20D
Measure the resistance value of each winding by using the multi-meter.
Model: RPG28D
Measure the resistance value of each winding by using the multi-meter.
Position
Resistance Value
Black - Red
372
Ω (20
Ԩ
)
Blue - Red
249
Ω (20
Ԩ
)
Yellow - Blue
132
Ω (20
Ԩ
)
Position
Resistance Value
Black - Red
114
Ω (20
Ԩ
)
Blue - Red
188
Ω (20
Ԩ
)
Yellow - Blue
172
Ω (20
Ԩ
)
Position
Resistance Value
Black - Red
400
Ω±8% (20
Ԩ
)
White - Black
383
Ω±8% (20
Ԩ
)
Position
Resistance Value
Black - Red
260
Ω±8% (20
Ԩ
)
White - Black
385
Ω±8% (20
Ԩ
)