 * RATING CONDITION: OUTDOOR AMBIENT TEMPERATURE 95F, SATURATED SUCTION TEMPERATURE 45F

 ** UNIT SUPPLIED FROM FACTORY ONLY 4.5 LB FOR PRE-CHARGED

Physical Data

Air Cooled Condensing Unit

Product Model

38LB

048SC

060SC

007SC

009SC

012SC

015SC

W

14,000

17,500

22,800

28,700

35,100

43,900

Btu/hr.

48,000

60,000

78,000

98,000

120,000

150,000

Power Consumption

W

4,200

5,240

6,170

9,370

10,830

14,330

Power Supply

V/Ph/Hz

380/3/50

Operating Current

Amp.

8.59

10.09

12.50

17.80

21.52

29.52

Compressor Type 

Scroll

QTY

1

1

1

1

1

1

RLA

Amp.

7.1

8.6

10.5

16.5

18.2

24.2

LRA

Amp.

56.0

74.0

101.0

146.0

147.0

175.0

Power Supply

V/Ph/Hz

220/1/50

Power Input

W

279

279

374

374

733

733

RLA

Amp.

1.49

1.49

2.00

2.00

3.92

3.92

Fan Type

Propeller

QTY

1

1

1

1

1

1

Drive Type

Direct

Hi-Pressure Switch

psig

395+10 / 275+15(Cut out / Cut in) - Auto Restart type

Low-Pressure Switch

psig

30+10 / 60+15(Cut out / Cut in) - Auto Restart type

Type

R-22

Pre-Charging from Facto

kg.

0.30

Liquid 

inch

3/8 (Flare)

1/2 (Flare)

5/8 (Flare)

Suction inch

7/8 

(Flare)

1-3/8 

(Brazing)

Height

mm.

690

845

1050

1150

Width

mm.

800

900

1040

1050

Depth

mm.

725

915

1080

1190

Weight

kg.

97

100

193

209

245

294

1-1/8 (Brazing)

Dimension 

Compressor  

Description

Nominal Cooling Capacity

Fan Motor

Safety Device

Refrigerant 

Piping Connections

38LB

38LF

38LF048

38LF060

38LF007

38LF009

38LF012

38LF015

Btu/hr.

48,000

60,000

78,000

98,000

120,000

150,000

w

14.1

17.6

22.9

28.7

28.7

44.0

Power Consumption

w

4,470

5,380

6,270

9,320

10,880

14,380

Power Supply

V/Ph./Hz

RLA

Amp.

8.89

10.39

12.90

18.00

21.62

30.42

Operating Weight (Approx)

kg.

97

100

193

209

240

260

Compressor

Type
Pre-Charging from Factory
Operation Charging

kg.

3.0

3.1

5.3

5.5

6.2

10.0

Type
Power Supply

V/Ph/Hz

Hi-Pressure Switch

psig

Low-Pressure Switch

psig

Liquid

inch

5/8

5/8

Suction

inch

1-1/8

1-3/8

Height

mm.

1050

1165

Width

mm.

1040

1035

Weigth

kg.

97

100

193

209

240

260

Dimension

Fully Hermetric Scroll Compressor

Fan Motor

Propeller Fan , Direct Drive

220/1/50

HFC R-407C

Refrigerant 

Nitrogen

Safety Device

395 / 275 (Cut out / Cut in) - Auto Restart type

30 / 60 (Cut out / Cut in) - Auto Restart type

Piping Connections

3/8
7/8

1/2

1-1/8

Description

Air Cooled Condensing Unit

Product Model

Nominal Cooling Capacity

380/3/50

800

690

845
900

** UNIT SUPPLIED FROM FACTORY ONRY NITROGEN

* RATING CONDITION: OUTDOOR AMBIENT TEMPERATURE 95 F, SATURATED SUCTION TEMPPERATURE  45 F

Summary of Contents for 38LB007SC

Page 1: ... UP AND SERVICE INSTRUCTIONS 38LB 38LF AIR COOLED CONDENSING UNIT CONTENTS PAGE PHYSICAL DATA 2 PHYSICAL DATA 2 DIMENSION DATA 3 RIGGING UNPACKING 4 CONFIGURATION 5 ELECTRICAL DATA 5 PIPING CONNECTIONS PIPING 6 MAINTENANCE 7 WIRING DIAGRAM 8 9 ATTENTION BEFORE OPERATING 10 1 ...

Page 2: ...1050 Depth mm 725 915 1080 1190 Weight kg 97 100 193 209 245 294 1 1 8 Brazing Dimension Compressor Description Nominal Cooling Capacity Fan Motor Safety Device Refrigerant Piping Connections 38LB 38LF 38LF048 38LF060 38LF007 38LF009 38LF012 38LF015 Btu hr 48 000 60 000 78 000 98 000 120 000 150 000 w 14 1 17 6 22 9 28 7 28 7 44 0 Power Consumption w 4 470 5 380 6 270 9 320 10 880 14 380 Power Sup...

Page 3: ...38LB 38LF Dimension mm Dimension mm 3 Dimension Data ...

Page 4: ...cessary x Confirm the nameplate voltage to ensure that it matches available power supply x Consult building and electrical codes as required in your area Location Unit should be installed outdoors Do not restrict service wiring and piping areas Also avoid positioning unit in manner restriction airflow or in areas where water will pour directly onto unit Minimum recommended clearance space is shown...

Page 5: ...p panel on front of unit and secure with screws 4 Final assembles fan discharge panel Pull fans motor wires taut and retie extra length in control box 5 Check fan for free rotation and observe that wiring has not been damaged or improperly strained 5 Min Max RLA LRA QTY RLA Power Wire mm 2 Ground Wire mm 2 Field CB AT 38LF048 380V 3Ph 50Hz 342 415 7 4 52 0 1 1 49 4 2 5 20 38LF060 380V 3Ph 50Hz 342...

Page 6: ...utdoor sections tubing 6 Thoroughly clean all tubing connection points to prevent foreign matter from entering the refrigerant circuit 7 Thread the 2 fittings by hand making sure the threads fit smoothly and the flare seats evenly against the union 8 Tighten the 2 fittings securely 9 Connect piping to the indoor and outdoor section 10 Evacuate the system at lower 500 micron for at least 30 minutes...

Page 7: ...ordinary hose at a pressure high enough to clean efficiently Coils are double row and may be separated carefully and sufficiently be loosening screws at one end of the coil so that dirt may be flushed out towards the outside of both coils Avoid splashing mud on coil or water onto fan motor Condensing fan adjustment The fan should be adjusted by loosening the set screws and moving the fan blade up ...

Page 8: ... 38LB036SCG 040SCG 048SC 060SC Å o µ 380 ê r ª Å o µ ε n 38LB007SC 009SC 009SC D 012SC 012SC D Å o µ 380 ê r 38LB 048SC 060SC 38LF 048 060SC 8 Wiring Diagram 38LB 007SC 009SC 009SC D 012SC 012SC D 38LF 007 009 012 ...

Page 9: ... L TB 8 LPS HPS GRN GRD 220V 50Hz AC CONTROL SUPPLY LEGEND COMPONENT ARRANGEMENT COMP COMPRESSOR C CONTACTOR CH CR CRANKCASE HEATER CONTROL RELAY LPS OFMC IP HPS LOW PRESSURE SWITCH OUTDOOR FAN MOTOR INTERNAL PROTECTOR HIGH PRESSURE SWITCH TM OFM CAPACITOR SOLID STATE TIMER OUTDOOR FAN MOTOR FIELD WIRING TERMINALS BLOCK TB CR TM C OFMC 1 2 4 3 8 N L 5 TB 1 2 5 6 3 4 TC RED TC THERMOSTAT CONNECTOR ...

Page 10: ...ding 7 After a long use check the unit fixing for damage 8 Before cleaning be sure to stop the operation and turn off the breaker As the fan is rotating at high speed cleaning during operation may cause injury 9 Do not place a vessel containing water or any object on the condensing unit and do not stand or sit on the condensing unit 10 The condensing unit should not be installed where normal opera...

Reviews: