Carrier reserves the right to make changes in specifications 

38LB/38LF_EN_11/2015

Attention before operating 

1.  Please read this installation manual 

carefully. It contains further important 

instructions. 

2.  Do not anything block the air outlet and 

air inlet of the condensing unit. The 

refrigeration system may be broken 

down. 

3.  Due to temperature of outlet air is higher 

around 50-60 degree C; it may be having 

an effect on environments especially tree, 

plant, or shrub etc. 

4.  Make sure that outlet air is moved out 

from installation area. It must not be 

return to air inlet. Do not be store until 

temperature above 42 degree C. The 

compressor or refrigeration system may 

be damaged. 

5.  For safety first, it should be turned off the 

breaker if the air conditioner does not be 

used for a long time. 

6.  If the condensing unit is installed on the 

ground, make sure that the location is not 

liable to flooding. 

7.  After a long use, check the unit fixing for 

damage. 

8.  Before cleaning, be sure to stop the 

operation and turn off the breaker. (As 

the fan is rotating at high speed, cleaning 

during operation may cause injury) 

9.  Do not place a vessel containing water or 

any object on the condensing unit and do 

not stand or sit on the condensing unit. 

10.  The condensing unit should not be 

installed where normal operation sounds 

may be objectionable. On either rooftop 

or ground level installations. Rubber 

padding can be applied between the 

base rails and their supports to lesson 

any transmission of vibration. 

11.  The fan of condensing unit is the 

propeller type. It is not suitable for use 

with duct work. 

12.  Make sure that the surrounding 

atmosphere does not contain noxious or 

dangerous substances such as oil vapors 

etc. 

Before inform our call center or inspect the air-conditioner, please check as 

following

Case of Air-conditioner does not work, 

 Disconnect 

the 

electrical? 

  Turn off the breaker? 

  Fuse is broken? 

  Low level of the battery show on 

remote control? 

  The timer function is set on 

remote control? 

Case of air-conditioner work but it can not 

cooling, 

  Fan-coil is unclean? 

  Open the door or the window? 

  Pre-Filter is unclean? 

  The position of louver is 

unsuitable? 

  Low speed on fan-coil unit? 

  The temperature setting is 

unsuitable set on remote control? 

Summary of Contents for 38LB007SC

Page 1: ... UP AND SERVICE INSTRUCTIONS 38LB 38LF AIR COOLED CONDENSING UNIT CONTENTS PAGE PHYSICAL DATA 2 PHYSICAL DATA 2 DIMENSION DATA 3 RIGGING UNPACKING 4 CONFIGURATION 5 ELECTRICAL DATA 5 PIPING CONNECTIONS PIPING 6 MAINTENANCE 7 WIRING DIAGRAM 8 9 ATTENTION BEFORE OPERATING 10 1 ...

Page 2: ...1050 Depth mm 725 915 1080 1190 Weight kg 97 100 193 209 245 294 1 1 8 Brazing Dimension Compressor Description Nominal Cooling Capacity Fan Motor Safety Device Refrigerant Piping Connections 38LB 38LF 38LF048 38LF060 38LF007 38LF009 38LF012 38LF015 Btu hr 48 000 60 000 78 000 98 000 120 000 150 000 w 14 1 17 6 22 9 28 7 28 7 44 0 Power Consumption w 4 470 5 380 6 270 9 320 10 880 14 380 Power Sup...

Page 3: ...38LB 38LF Dimension mm Dimension mm 3 Dimension Data ...

Page 4: ...cessary x Confirm the nameplate voltage to ensure that it matches available power supply x Consult building and electrical codes as required in your area Location Unit should be installed outdoors Do not restrict service wiring and piping areas Also avoid positioning unit in manner restriction airflow or in areas where water will pour directly onto unit Minimum recommended clearance space is shown...

Page 5: ...p panel on front of unit and secure with screws 4 Final assembles fan discharge panel Pull fans motor wires taut and retie extra length in control box 5 Check fan for free rotation and observe that wiring has not been damaged or improperly strained 5 Min Max RLA LRA QTY RLA Power Wire mm 2 Ground Wire mm 2 Field CB AT 38LF048 380V 3Ph 50Hz 342 415 7 4 52 0 1 1 49 4 2 5 20 38LF060 380V 3Ph 50Hz 342...

Page 6: ...utdoor sections tubing 6 Thoroughly clean all tubing connection points to prevent foreign matter from entering the refrigerant circuit 7 Thread the 2 fittings by hand making sure the threads fit smoothly and the flare seats evenly against the union 8 Tighten the 2 fittings securely 9 Connect piping to the indoor and outdoor section 10 Evacuate the system at lower 500 micron for at least 30 minutes...

Page 7: ...ordinary hose at a pressure high enough to clean efficiently Coils are double row and may be separated carefully and sufficiently be loosening screws at one end of the coil so that dirt may be flushed out towards the outside of both coils Avoid splashing mud on coil or water onto fan motor Condensing fan adjustment The fan should be adjusted by loosening the set screws and moving the fan blade up ...

Page 8: ... 38LB036SCG 040SCG 048SC 060SC Å o µ 380 ê r ª Å o µ ε n 38LB007SC 009SC 009SC D 012SC 012SC D Å o µ 380 ê r 38LB 048SC 060SC 38LF 048 060SC 8 Wiring Diagram 38LB 007SC 009SC 009SC D 012SC 012SC D 38LF 007 009 012 ...

Page 9: ... L TB 8 LPS HPS GRN GRD 220V 50Hz AC CONTROL SUPPLY LEGEND COMPONENT ARRANGEMENT COMP COMPRESSOR C CONTACTOR CH CR CRANKCASE HEATER CONTROL RELAY LPS OFMC IP HPS LOW PRESSURE SWITCH OUTDOOR FAN MOTOR INTERNAL PROTECTOR HIGH PRESSURE SWITCH TM OFM CAPACITOR SOLID STATE TIMER OUTDOOR FAN MOTOR FIELD WIRING TERMINALS BLOCK TB CR TM C OFMC 1 2 4 3 8 N L 5 TB 1 2 5 6 3 4 TC RED TC THERMOSTAT CONNECTOR ...

Page 10: ...ding 7 After a long use check the unit fixing for damage 8 Before cleaning be sure to stop the operation and turn off the breaker As the fan is rotating at high speed cleaning during operation may cause injury 9 Do not place a vessel containing water or any object on the condensing unit and do not stand or sit on the condensing unit 10 The condensing unit should not be installed where normal opera...

Reviews: