Carrier 38EYA Product Data Download Page 4

 

4

 

Accessories

 

† For indicator light function, thermostat specified must be used and wired according to service alarm Installation Instructions.
‡ Must be applied on coils not equipped with Puron TXV.

* Do not use in zoning heat pump applications.

† This plate is designed to cover surrounding wall area located behind thermostat.
‡ Thermostat conversion kit is a 24-vac accessory that can turn a 4-wire thermostat application into a 5-wire application. This kit can also be used to replace 

a broken thermostat wire, or add an extra wire when needed.

** Outdoor temperature sensor is an accessory for all Carrier electronic thermostats, except the non-programmable air conditioner version and builder’s 

thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat.
The outdoor air temperature sensor 

 

must be

 

 used with the dual fuel thermostat.

The outdoor air temperature sensor is included with the Thermidistat Control and dual fuel thermostat.

 

ORDERING

NUMBER

DESCRIPTION

KAATD0101TDR

 

Time-Delay Relay — All Sizes

 

KSALA0301410

 

Low-Ambient Pressure Switch — All Sizes

 

KAAFT0101AAA

 

Evaporator Freeze Thermostat — All Sizes

 

KHAIR0101AAA

 

Isolation Relay — All Sizes

 

KSAHS1501AAA

 

Start Capacitor and Relay — Sizes 024–042

 

KSAHS1601AAA

 

Start Capacitor and Relay — Sizes 048, 060

 

Standard

 

Start Assist — PTC — Sizes 024–048 (30), 024 (31)

 

KAACS0201PTC

 

Start Assist — PTC — Size 060 (30), 030–060 (31)

 

KAACH1201AAA

 

Crankcase Heater — Sizes 024–042

 

Standard

 

Crankcase Heater — Sizes 048, 060

 

KHAOT0301FST

 

Outdoor Thermostat — All Sizes

 

KHAOT0201SEC

 

Secondary Outdoor Thermostat — All Sizes

 

KHASA0101AAA†

 

Service Alarm — All Sizes

 

KHAIC0101AAA

 

Interface Control (Optimizer II®) — All Sizes

 

KSATX0201HSZ‡

 

Bi-Flow TXV (Hard Shutoff) — Size 024, 030

 

KSATX0301HSZ‡

 

Bi-Flow TXV (Hard Shutoff) — Sizes 036, 042

 

KSATX0401HSZ‡

 

Bi-Flow TXV (Hard Shutoff) — Size 048

 

KSATX0501HSZ‡

 

Bi-Flow TXV (Hard Shutoff) — Size 060

 

KH45LG140 (RCD)

 

Filter Drier— Suction Line — Sizes 024–036

 

KH45LG141 (RCD)

 

Filter Drier— Suction Line — Sizes 042–060

 

KHALS0401LLS

 

Liquid-Line Solenoid Valve — All Sizes

 

KAACF1001MED

 

Coastal Filter — Sizes 024, 030

 

KAACF1101LRG

 

Coastal Filter — Sizes 036-060

 

KSASH1801COP

 

Sound Hood — Sizes 024, 030

 

KSASH0601 COP

 

Sound Hood — Sizes 036-048

 

KSASH2101COP

 

Sound Hood — Size 060

 

P165-0001 (RCD) (2 REQ’D/UNIT)

 

Unit Risers — All Sizes

 

KSACG1004CSM

 

Inlet Grille Kit — Size 024

 

KSACG1404CSM

 

Inlet Grille Kit — Size 030

 

KSACG1804CSM

 

Inlet Grille Kit — Size 036

 

KSACG2304CSM

 

Inlet Grille Kit — Size 042, 048

 

KSACG2004CSM

 

Inlet Grille Kit — Size 060

 

 THERMOSTAT/SUBBASE PKG

DESCRIPTION

TSTATCCNHP01-B

 

Thermostat — Auto Changeover, Non-Programmable, °F/°C, 2-Stage Heat, 1-Stage Cool

 

TSTATCCPHP01-B

 

Thermostat — Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat, 1-Stage Cool

 

TSTATCCBHP01*

 

Builder’s Thermostat — Heat Pump, Non-Programmable, °F/°C, 2-Stage Heat, 1-Stage Cool, 
Manual Changeover

 

TSTATCCSHP01

 

Standard Programmable Thermostat—Manual Changeover, 5-2 Day Programmable, °F/°C, 1-Stage Heat/
1-Stage Cool

 

TSTATXXSEN01-B**

 

Outdoor Air Temperature Sensor

 

TSTATCCPDF01-B*

 

Dual Fuel Thermostat — Auto Changeover, 7-Day Programmable, °F/°C, Includes Outdoor Sensor 
(TSTATXXSEN01-B)

 

TSTATCCPRH01-B*

 

Thermidistat™ Control — Non-Programmable/Programmable Thermostat with Humidity Control 
(For use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.)

 

TSTATXXNBP01†

 

Backplate for Non-Programmable Thermostat

 

TSTATXXPBP01†

 

Backplate for Programmable Thermostat and Thermidistat™ Control

 

TSTATXXSBP01†

 

Backplate for Standard Programmable Thermostat

 

TSTATXXBBP01†

 

Backplate for Builder’s Thermostat

 

TSTATXXCNV10‡

 

Thermostat Conversion Kit (4 to 5 Wire) — 10 Pack

Summary of Contents for 38EYA

Page 1: ...n thanks to the performance advantage of Puron the 38EYA is extremely efficient with ratings from 12 to 14 SEER Maximum performance and efficiency are made possible through the use of the FX4A and FV4...

Page 2: ...service reversing valve Thermostatic Expansion Valve TXV The 38EYA Heat Pump must be installed with a Puron TXV on the indoor coil The FX4 and FV4 indoor fan coils are factory equipped with a bi flow...

Page 3: ...8 3 8 5 8 3 4 ACR 3 4 030 3 8 3 8 3 4 7 8 1 1 8 036 3 8 3 8 3 4 7 8 1 1 8 042 048 3 8 3 8 7 8 7 8 3 4 and 1 1 8 060 3 8 3 8 1 1 8 7 8 3 4 RST Refrigeration Service Tubing standard refrigerant grade tu...

Page 4: ...Flow TXV Hard Shutoff Size 024 030 KSATX0301HSZ Bi Flow TXV Hard Shutoff Sizes 036 042 KSATX0401HSZ Bi Flow TXV Hard Shutoff Size 048 KSATX0501HSZ Bi Flow TXV Hard Shutoff Size 060 KH45LG140 RCD Filt...

Page 5: ...mp and gas or oil fired furnace combination systems unless Duel Fuel Thermostat or Thermidistat Control is used 9 Isolation Relay An SPDT relay which switches the Low Ambient Controller out of the out...

Page 6: ...pacity of nonmetallic sheathed cable NM trade name ROMEX shall be that of 60 C 140 F conductors per the NEC ANSI NFPA 70 Article 336 26 If other than uncoated non plated 60 or 75 C 140 or 167 F insula...

Page 7: ...Minimum outdoor operating ambient in cooling mode is 55 F 2 NOTES unless low ambient control is used max 125 F DIMENSIONS IN UNIT SIZE SERIES UNIT DIMENSIONS MINIMUM MOUNTING PAD DIMENSIONS A B C D E...

Page 8: ...BASED ON INDOOR ENT AIR AT 70 F AND AT RATED CFM 23 4 20 5 17 6 14 7 11 7 8 8 5 9 2 9 38EYA024 301 FX4A030 38EYA036 301 FX4ANF036 38EYA048 301 FX4A048 KW 38EYA060 301 FX4ANF060 NOTE The performance s...

Page 9: ...TDR 13 50 11 35 29 000 3 52 17 800 2 42 8 00 F A B 4AN F C 036 28 000 TDR 11 50 9 90 30 000 3 30 18 900 2 26 7 50 FC4BNF036 28 000 TDR 11 50 9 90 30 000 3 30 18 900 2 26 7 50 FG3AAA036 28 000 NONE 11...

Page 10: ...35 000 3 56 22 200 2 54 8 00 COILS 58U H X V100 20 VARIABLE SPEED FURNACE CC5A CD5AA042 33 400 TDR 13 50 11 30 35 000 3 44 21 800 2 50 7 80 CC5A CD5AA048 33 800 TDR 13 50 11 25 35 000 3 48 22 000 2 5...

Page 11: ...8 20 FC4BN F B 060 44 000 TDR 11 50 9 75 47 000 3 44 29 800 2 40 8 00 FC4BNB070 45 000 TDR 12 00 10 25 47 000 3 62 29 400 2 50 8 20 FG3AAA060 43 500 NONE 12 00 10 15 46 000 3 38 29 000 2 42 8 00 FV4A...

Page 12: ...22 TXV with Puron TXV UNIT SIZE SERIES INDOOR UNIT ARI STANDARD RATINGS Cooling Heating TC Seasonal Efficiency SEER EER High Temp Low Temp HSPF Factory Supplied Enhance ment Standard Rating Field Supp...

Page 13: ...5 2 20 22 2 21 9 2 44 20 9 20 9 2 71 19 7 19 7 3 00 18 2 18 2 3 30 57 24 1 24 1 1 97 23 1 23 1 2 20 22 1 22 1 2 44 20 9 20 9 2 71 19 6 19 6 3 00 18 2 18 2 3 30 950 72 29 7 15 7 2 04 28 1 15 1 2 27 26...

Page 14: ...2 73 24 9 24 9 3 02 23 3 23 3 3 34 21 6 21 6 3 69 57 28 8 28 8 2 24 27 6 27 6 2 48 26 2 26 2 2 73 24 9 24 9 3 02 23 3 23 3 3 34 21 6 21 6 3 69 1200 72 34 6 18 9 2 34 32 8 18 3 2 57 30 9 17 7 2 82 28 9...

Page 15: ...8 25 8 4 57 63 36 1 29 6 2 78 34 1 28 8 3 08 32 1 27 9 3 41 29 9 27 0 3 76 27 5 25 9 4 14 24 9 24 5 4 55 62 36 3 36 3 2 78 34 6 34 6 3 08 32 9 32 9 3 41 31 0 31 0 3 77 28 9 28 9 4 16 26 5 26 5 4 57 5...

Page 16: ...1575 72 49 7 26 3 3 24 47 1 25 5 3 60 44 5 24 6 4 00 41 7 23 6 4 44 38 6 22 6 4 93 35 0 21 5 5 44 67 45 6 34 7 3 21 43 3 33 8 3 57 40 9 32 9 3 97 38 3 31 8 4 41 35 4 30 7 4 89 32 2 29 4 5 40 63 42 6...

Page 17: ...50 40 4 40 4 4 99 37 9 37 9 5 54 35 0 35 0 6 13 1800 72 55 9 30 2 3 85 52 9 29 2 4 24 49 9 28 2 4 68 46 6 27 1 5 17 43 1 26 0 5 70 39 1 24 7 6 28 67 51 3 40 1 3 80 48 6 39 0 4 19 45 8 38 0 4 63 42 9...

Page 18: ...8 39 0 6 97 45 4 37 3 7 68 63 59 1 43 2 4 62 56 2 41 9 5 12 53 2 40 6 5 66 50 0 39 2 6 27 46 5 37 7 6 93 42 5 36 0 7 63 62 58 2 53 8 4 61 55 4 52 4 5 11 52 5 51 0 5 65 49 4 49 3 6 26 46 5 46 5 6 93 4...

Page 19: ...2 2 37 950 10 8 9 97 2 06 13 1 12 0 2 05 15 6 14 2 2 07 18 4 16 3 2 11 21 7 19 7 2 16 25 4 25 4 2 23 26 5 26 5 2 31 27 6 27 6 2 32 75 700 10 5 9 64 2 07 12 6 11 6 2 10 15 0 13 7 2 16 17 7 15 7 2 23 20...

Page 20: ...0 2 58 33 1 33 1 2 56 35 4 35 4 2 61 1200 13 2 12 2 2 37 15 9 14 6 2 38 19 0 17 3 2 40 22 4 19 9 2 45 26 2 23 8 2 51 30 4 30 4 2 58 33 6 33 6 2 54 35 5 35 5 2 55 75 900 13 1 12 1 2 35 15 3 14 1 2 40 1...

Page 21: ...4 0 3 04 31 5 28 7 3 16 36 5 36 5 3 29 35 8 35 8 3 21 34 3 34 3 3 10 1500 16 5 15 2 2 90 19 7 18 1 2 94 23 4 21 3 3 01 27 5 24 5 3 09 32 1 29 2 3 19 37 2 37 2 3 30 36 5 36 5 3 21 35 0 35 0 3 09 Indoor...

Page 22: ...19 4 17 8 3 46 23 0 21 1 3 43 26 9 24 6 3 40 31 1 27 6 3 37 35 7 32 5 3 35 40 8 40 8 3 32 44 5 44 5 4 05 42 3 42 3 3 87 1400 19 9 18 3 3 53 23 3 21 4 3 47 27 3 24 9 3 42 31 6 28 0 3 37 36 3 33 0 3 33...

Page 23: ...7 4 11 57 3 57 3 4 23 75 1400 20 4 18 8 3 46 24 3 22 3 3 53 28 8 26 2 3 64 33 7 29 9 3 78 39 3 35 8 3 94 45 6 45 6 4 13 50 2 50 2 4 35 54 2 54 2 4 51 1600 20 7 19 1 3 55 24 7 22 7 3 59 29 2 26 6 3 68...

Page 24: ...60 8 5 01 58 8 58 8 5 02 58 6 58 6 4 95 2000 26 6 24 5 4 22 32 6 29 9 4 37 38 7 35 2 4 48 45 4 40 4 4 62 53 1 48 3 4 79 61 7 61 7 4 98 59 8 59 8 4 97 59 6 59 6 4 88 2250 27 0 24 8 4 29 33 0 30 3 4 48...

Page 25: ...onnecting refrigerant tube lengths greater than 50 ft and or elevation differences between indoor and outdoor units greater than 20 ft consult Residential Split System Application Guideline and Servic...

Page 26: ...26...

Page 27: ...27...

Page 28: ...art up Unit Cabinet Unit cabinet will be constructed of galvanized steel bonderized and coated with a powder coat paint Fans Condenser fan will be direct drive propeller type discharging air upward Co...