background image

2

Adapter Harness
Remove and discard.

Old Style ECM Inducer

New Style ECM Inducer

A13034

Fig. 1 -- ECM Inducers

DESCRIPTION AND USAGE

Use this inducer assembly kit to replace a failed inducer assembly.

The assembly cannot be disassembled to remove or repair individual

components. The kit contains the following items shown in

Table 1

.

NOTE

:

Inducer assembly consists of motor, wheel, inducer

housing, inlet gasket, inlet choke plate and condensate drain
gasket. It will be necessary to reuse some components from the old
inducer assembly.

UNIT DAMAGE HAZARD

Failure to follow this caution may result in unit damage.
Using the incorrect inducer motor assembly could result in no

pressure switch operation, poor ignition, poor combustion,

erratic burner operation/burner pulsations, flame roll--out or

noise.

CAUTION

!

Table 1 – Kit Contents

NAME

QUANTITY

Inducer Assembly

1

Installation Instructions

1

Inlet Choke Plate (PSC and Ultra Low NOx only)

1 -- 2

Inducer Outlet Restrictor (40,000 input only)

1

Two--stage to Single--stage Adapter Harness (PSC

only except 140,000 input)

1

1/2--in.. # 8 Hex Head Screws 1 /2--in.

5

3/8--in. # 8 Hex Head Screws

2

Table 2 – Model Numbers

SINGLE SPEED PSC INDUCER MODELS

INPUT

KIT NUMBER

26,000

337938--784--CBP*

40,000
60,000

337938--785--CBP*

80,000

100,000

337938--786--CBP*

120,000
140,000

337938--787--CBP*

TWO SPEED PSC INDUCER MODELS

INPUT

KIT NUMBER

40,000

337938--784--CBP*

60,000

337938--785--CBP*

80,000

100,000

337938--786--CBP*

120,000

MODULATING MODELS

INPUT

KIT NUMBER

60,000

337938--790--CBP*

80,000

100,000
120,000

ULTRA LOW NOX MODELS

INPUT

KIT NUMBER

60,000

337938--790--CBP*

80,000

100,000

SINGLE SPEED EXPORT MODELS (220 VOLT, 50 HZ ONLY)

INPUT

KIT NUMBER

100,000

337938--782--CBP*

120,000
140,000

*All Brands

INSTALLATION

Unit Shut Down

ELECTRICAL SHOCK AND FIRE HAZARD

Failure to follow this warning could result in personal injury,

death, and/or property damage.
Turn off the gas and electrical supplies to the furnace and

install lockout tag before performing any maintenance or

service. Follow the operating instructions on the label

attached to the furnace.

!

WARNING

1. Set room thermostat to lowest setting or “OFF”.
2. Disconnect power at external disconnect, fuse or circuit

breaker.

3. Turn off gas at external shut-off or gas meter.
4. Remove outer doors and set aside.
5. Turn electric switch on gas valve to OFF.

Vent Pipe Removal

NOTE

: The vent pipe may be connected to the furnace at the

rubber vent pipe support. Before cutting the vent pipe, loosen the
clamps around the vent pipe coupling and move the vent pipe
away from the furnace. Support the vent pipe as close to the
furnace as possible to prevent damage to the vent system.

NOTE

: If the vent pipe passes through the vent pipe coupling into

the vent elbow on the inducer, it may be necessary to cut the vent
pipe external to the casing, then re--cement the vent pipe with a
field--supplied coupling.

337938