background image

 ©2019 Carrier Corp.• 7310 W. Morris Street • Indianapolis, IN 46231

Edition Date: 09/19

Catalog No: OM24VNA9-03

Replaces: OM24VNA9-02

24VNA9: Owner’s Manual

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

2

• Keep Filter Clean

A  clogged  or  improperly  installed  air  filter  on  your  indoor  unit  will

increase operating costs and shorten the life of  the unit.  For detailed

filter cleaning information refer to indoor unit  literature.

• Do Not Block Floor, Wall or Ceiling Vents 

When  drapes, furniture, toys or  other common  household items block

vents, the restricted airflow lessens the system’s efficiency and life span.  

• Do Not Cover or Block Outdoor Unit

The  outdoor  unit  needs  unrestricted  airflow.  Do  not  cover  it  or  place

items  on  or  next  to  it.  Do  not  allow  grass  clippings,  leaves,  or  other

debris to accumulate on the sides or top of the unit. And, maintain a 12”

(305 mm) minimum clearance between the outdoor unit and tall grass,

vines, shrubs, etc. 

• Check Condensate Drain

Your  air  conditioner  removes  humidity  from  your  home  during  the

cooling season. After a few minutes of operation, water should trickle

from the condensate drain of the indoor coil. Check this occasionally to

be sure the drain system is not clogged. Drainage will be limited if you

live in a very dry environment.  

• Do  Not  Operate  Below  Minimum  Operating  Temperatures  in

Cooling Mode

Your  outdoor  unit  is  not  designed  to  operate  below  the  minimum

temperatures  shown  below.  The  minimum  temperature  depends  on

which wall control is being used:

—With Infinity Touch Control:   40°F (4°C)

—With Thermostat Control:  55°F (13°C)

System  protections  may  not  allow  the  unit  to  operate  below  these

minimum temperatures.

• Base Pan Drainage 

Periodically check for and remove debris that has settled around the base

of your outdoor unit.  This will ensure proper drainage of the base pan

and eliminate standing water inside the outdoor unit. 

• Level Installation 

Your Carrier dealer will install the outdoor unit in a level position.  If the

support base settles or shifts and the unit is no longer level, be sure to

re-level it promptly to assure proper drainage. If you notice water or ice

collecting beneath the unit, arrange for it to be drained away from the

unit. 

SEA COAST COIL MAINTENANCE

Coastal  locations  often  require  additional  maintenance  of  the  outdoor

unit  due  to  highly  corrosive  airborne  ocean  salt. Although  your  new

Carrier system is made of galvanized metal and is protected by top-grade

paint, take the additional precaution of periodically washing all exposed

surfaces  and  the  outdoor  coil  approximately  every  3  months.  Consult

your  installing  Carrier  dealer  for  proper  cleaning  intervals  and

procedures for your geographic area or ask about a service contract for

regularly scheduled professional cleaning and inspections. 

TROUBLESHOOTING 

Before  you  request  dealer  service,  check  for  these  easily  solved

problems: 

• Check the indoor and outdoor disconnect switches  Also check your

main electrical panel circuit breakers or fuses.

• Check for sufficient airflow.  Air filter(s) should be reasonably clean

and interior vents should be open and unobstructed.

• Check  Infinity  Touch  Control  or  thermostat  settings.    For  cooling,

your  desired  temperature  setting  should  be  LOWER  than  the

displayed room temperature, and the System/Mode control should be

on Cool or Auto.  

• Time delays - depending on the Carrier air conditioner you have, there

may  be  delays  in  unit  operation  that  are  built-in  to  protect  the

equipment and your comfort.  Don't be alarmed if you notice a time

delay in operation.  It may be a standard protection feature of your

equipment.  Check with your Carrier Dealer for more information on

time delays.

If  you  need  to  contact  your  Carrier  dealer  for  troubleshooting  and/or

repairs, be sure to have the model and serial numbers of your equipment

available  (there  are  spaces  on  the  cover  for  you  to  write  this

information). 

REGULAR DEALER MAINTENANCE

In  addition  to  the  routine  maintenance  that  you  perform,  your  home

comfort  system  should  be  inspected  regularly  by  a  properly  trained

service technician. Many dealers offer this service at a reduced rate with

a service contract.  Some service contracts offer additional benefits such

as  parts  discounts  and  no  additional  charge  for  ”after  hours”  or

emergency service.

* Monthly maintenance items and outdoor unit rinsing may be performed by the consumer. All other maintenance items and all service work must be performed by a qualified service technician. Read all waring labels.

Notes:

1.

The above list may not include all maintenance items. Inspection intervals may vary depending on climate and operating hours. Consult your HVAC dealer about a service contract for seasonal inspections.

2.

Do not use harsh chemicals or high pressure water on coils. More frequent rinsing is required for units near a sea coast.

Maintenance Checklist

Recommended

Interval*

Outdoor unit specific:

Monthly

Annual

Clear away debris and vegetation near unit.

X

Inspect cabinet for damage. Replace components that are damaged or severely rusted.

X

Inspect electrical disconnect for proper function. Repair or replace as necessary.

X

Inspect electrical wiring and connections.  Tighten loose connections. Inspect and perform functional test of equipment as needed to ensure proper 

function. Repair or replace damaged or overheated components and wiring.

X

Check refrigerant system subcooling and/or superheat (system dependent).

X

Inspect inside of unit. Clean if debris is present.

X

Inspect condenser coil. Clean if dust, dirt, or debris is present.  Rinse unit with fresh water (see Note 2).

X

Inspect motor and fan for damage. Make sure fan spins freely.

X

Indoor specific:  (for fossil fuel furnaces and accessories, refer to unit specific literature)

Inspect, clean, or replace air filter if dirty.

X

Inspect and clean blower assembly (includes blower housing, wheel, and motor).

X

Inspect internal and external of cabinet. Clean as needed.

X

Inspect electrical disconnect for proper function. Repair or replace as necessary.

X

Inspect electrical components, wiring, and connections. Tighten loose connections. Repair or replace damaged components and wiring.

X

Inspect evaporator coil. Clean if dust, dirt, or debris is present (see Note 2).

X

Clean condensate pan, trap, and drain lines (more frequent maintenance may be required in humid climates - consult your local HVAC dealer).

X

Inspect airflow system (ductwork). Check for leaks and repair as needed.

X

Reviews: