17
COMBINATION RATINGS CONTINUED
Unit Size ---
Voltage,
Series
Indoor
Model
Total Cap.
BTUH
Factory
Supplied
Enhancement
SEER
EER
Furnace
Model
Standard
Rating
TDR
{
60---32/33
60---52/53
60---62/63
CSRH*6012A**
57,000
TXV
13.00
11.00
CSRH*6012A**
56,500
TDR&TXV
13.20
11.00
58CV(A,X)135---22
CSRH*6012A**
56,500
TDR&TXV
13.50
11.20
58CV(A,X)155---22
FA4CN(F,C)060
56,500
TDR&TXV
13.00
11.00
FC4DN(F,B)060
57,500
TDR&TXV
13.20
11.00
FK4DNB006
57,000
TDR&TXV
13.50
11.20
* Tested combination
{
In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use
either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Carrier furnaces are equipped with TDR.
EER
— Energy Efficiency Ratio
SEER
— Seasonal Energy Efficiency Ratio
TDR —
Time---Delay Relay
TXV
— Thermostatic Expansion Valve
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other
combinations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are significantly affected.
24ABR3