![Carrier 2.4L Owner'S Manual Download Page 13](http://html1.mh-extra.com/html/carrier/2-4l/2-4l_owners-manual_2563734013.webp)
3. No Flywheel Signal — LED blinks two (2) times,
is OFF for three (3) seconds and then repeats.
4. No Cam Signal — LED blinks three (3) times, is
OFF for three (3) seconds and then repeats.
Only one LED fault code is displayed at a time.
If multiple fault codes exist then the highest priority
fault must be resolved prior to a lower priority fault
code being displayed.
The LED fault code blink pattern is displayed for 60
– 120 seconds after a fault and then the ignition will
power itself down.
The Generator must have been in the OFF mode for
60 seconds prior to cranking for the Flywheel and
CAM LED fault diagnostics to be valid.
The Flywheel and CAM LED fault codes are not valid
during a re-crank.
NOTE:
There are openings inside the customer wiring
panel that allow the RED LED inside the ignition
module to be seen without removing the ignition
module.