LEDs
The LEDs on the front panels of the FLEXmaster16, FLEXmaster8A and FLEXmasterDS3c
application modules are described below.
Module Status
Link Status - FLEXmaster16 and FLEXmaster8A
For more details about individual alarms, see the Card Statistics window (see
LED
State
Description
PST
blinking
Passed power on self test.
Indicates this is the master module for the chassis.
ALM
solid red
Alarm - failed power on self test
State
Description
solid red
OOF- out of frame.
AIS
solid green
Link is up.
blinking red
LOS.
solid yellow
Yellow sync alarm or RAI. Indicates red alarm on the far end.
blinking yellow
Diagnostic function present.
off
Link is disabled.
-
PST ALM
-
T
1
/E
1
S
T
A
T
U
S
1
5
3
7
9
13
11
15
2
6
4
8
10
14
12
16