background image

Operation and Maintenance 

Smart Command Intelligent Eco Valve

2. Safety

2. Safety

3. Installation instructions

3. Installation instructions

Please observe the prescribed values for voltage and power (see specifications).

Work on electrical installations or controls must be made by qualified electricians only.

Disconnect the mains adapter and remove the battery prior to working on the installation.

Regularly check the mains adapter and have it removed by a qualified electrician in case it is damaged.

2.4  Maintenance and repair work

2.4  Maintenance and repair work

Maintenance and repair work must be done by qualified and authorised Caroma specialists only. They are 
considered authorised specialists because of their vocational training, instruction or experience to do the required 
intervention, detect and prevent potential risks from occurring in pursuing their activities. They must be able to 
provide evidence about their knowledge of the relevant safety standards, safety regulations and health and safety 
regulations, and they must have read the instructions for use.

The Caroma Eco Valve communicates via Bluetooth

®

.

In unfavourable ambient conditions, in buildings or rooms with walls made of reinforced concrete, steel or iron 
frames or near metal barriers (e.g. pieces of furniture), radio reception may be impaired or interrupted. Possibly, an 
additional Gateway will have to be installed to increase the range of the radio signal.

The Caroma Eco Valve must be installed in frost-proof, non-condensing rooms. The Caroma Eco Valve must 

NOT

 be 

installed in inaccessible ducts.

Once installed and commissioned, the Caroma Eco Valve should be connected to the Caroma Smart Command 
system to enable remote monitoring and configuration.

Summary of Contents for Smart Command Eco Valve

Page 1: ......

Page 2: ...6 3 Installation instructions 6 4 Design and function 7 4 1 Scope of supply 7 4 2 Design 8 4 3 Function 8 5 Transport and storage 9 5 1 Transport 9 5 2 Storage 9 6 Installation and commissioning 10 6 1 Safety instructions on installation and commissioning 10 6 2 Installation 11 7 Operation and settings 13 7 1 Operation and settings via the Smart Command App 13 7 2 Displays and actions directly on ...

Page 3: ...afety instructions are signalled in the present instructions for use by respective symbols The signal words at the beginning of the safety instructions are an expression of the extent of the risk Danger The combination of the symbol and the signal word indicates direct danger and a situation which if not avoided could result in death or severe injury Warning The combination of the symbol and the s...

Page 4: ...of Caroma The following Australian standards of certification have been applied for the development and design of the Caroma Eco Valve WMTS 479 2018 AS4020 WaterMark The manufacturer s warranty is subject to the sales terms and conditions of delivery The warranty expires in case of Damage due to improper operation Repair or conversion work performed by unauthorised persons Use of non original Caro...

Page 5: ...devices Therefore please follow safety and health regulations other generally accepted rules pertaining to safety and occupational health and safety regulations Do not modify the Caroma Eco Valve The manufacturer does not assume any liability for damage due to improper alterations 2 3 Hazards due to electric energy 2 3 Hazards due to electric energy In general danger can occur when handling electr...

Page 6: ... to do the required intervention detect and prevent potential risks from occurring in pursuing their activities They must be able to provide evidence about their knowledge of the relevant safety standards safety regulations and health and safety regulations and they must have read the instructions for use The Caroma Eco Valve communicates via Bluetooth In unfavourable ambient conditions in buildin...

Page 7: ...Design and function 1 2 3 4 5 6 Legend 1 Valve unit 2 9V battery included 3 Emergency unlocking key 4 Mains power supply 5 Pipe adapters 2x 6 Commissioning operation and maintenance manual 4 1 Scope of supply 4 1 Scope of supply ...

Page 8: ...Command Cloud connection the Eco Valve transmits data e g volume flow flow rate per time duration of volume flow pressure drop and temperature via a secure connection Even if the Internet connection is down the parameters will continue to be monitored However during that period there is no communication with the server and no notification Of course the system can also operate without Internet conn...

Page 9: ...nly Temperature 4 to 60 C relative air humidity max 80 Attention Improper transport may damage the device The packaging serves as protection during transport Do not install the device if the packaging is severely damaged When subjected to hard shocks or impacts replace the synthetic part concerned even if it presents no visible damage Attention Improper storage may damage the device Protect the va...

Page 10: ...s and regulations of the local water provider Any other local regulations that apply to the installation site Attention Improper installation of the drinking water device may cause damage Follow the instructions for use to mount the Caroma Eco Valve Check that the connection is leaktight Avoid strong water hammers caused e g by downstream solenoid valves Attention Drinking water pollution may caus...

Page 11: ...ush the pipes before installation An optional water filter may be installed upstream of the valve if required Water flow direction Point of entry installation Eco Valve Please pay attention to the Flow Direction arrow marked on the housing Re open the water supply Check that the valve connections are water tight Open the battery compartment and insert the 9V block battery supplied Be sure to obser...

Page 12: ...d Maintenance Smart Command Intelligent Eco Valve 6 Installation and commissioning 6 Installation and commissioning Insert the battery Plug in the mains adapter to ensure power supply The device is now ready to use ...

Page 13: ... Caroma Smart Command App on your smartphone or tablet Simply install the current Caroma Smart Command App on your smartphone or tablet You will find exact instructions for the commissioning of your device in the appended instructions The Smart Command Eco Valve can also be used without a connection to the Smart Command system In this case functions like notification by text messages or e mail are...

Page 14: ... addition to the amount of water set for volume based leakage a period of time can be determined when water may be drawn without interruption If for example the time based leakage is set to 60 minutes the Eco Valve will isolate the system once this time has elapsed even if the set volume has not yet been reached Flow based leakage 60 minutes If the Eco Valve detects unusual flow rates within short...

Page 15: ... off Self learning phase On During the self learning phase the Caroma Eco Valve analyses water consumption and the typical usage The measured values can then be used for your own selected profile The duration of the self learning phase can range between one and 28 days Off Warning sound buzzer ...

Page 16: ...isplay Green Red LED lights up Active leakage protection General fault LED flashes Motor opens closes active flow Suspected leak 7 1 1 LED displays LED LCD display Touch switch Condition of device Action Function Shut off valve open Touch Sensor Hold for 3s Shut off valve closes Shut off valve closed Touch switch Hold for 3s Shut off valve opens Fault red LED on Shut off valve closed Touch switch ...

Page 17: ...Eco Valve can be manually unlocked for instance in case of loss of energy supply due to power failure or a missing or spent battery The access to the emergency unlocking function is underneath the control unit Carefully remove cover No cables have to be removed One by one remove the battery compartment and the housing of the Eco Valve ...

Page 18: ...rt Command Intelligent Eco Valve 8 Emergency unlocking function 8 Emergency unlocking function A A C C B B Remove the emergency unlocking key A the battery B and the battery compartment C Pull the casing upwards and tip it sideways ...

Page 19: ...ing key from the top and turn it clockwise until water starts to flow Remove the wire clamp that connects the body of the Eco Valve with the motor unit and place the motor unit next to it sideways without removing the cables thus opening access to the shut off valve Note Electronics not shown ...

Page 20: ...ntelligent Eco Valve 8 Emergency unlocking function 8 Emergency unlocking function Once you have drawn water turn the shut off valve by using the key until it is closed again and the water ceases to flow Re assemble the device in reverse order ...

Page 21: ...nsor 6 Conductivity cartridge 7 Inlet strainer Power supply no illustration 510010 Pressure sensor with cable 510012 Conductivity cartridge 510013 Reed switch no illustration 510014 Inlet strainer complete 510015 Temperature sensor no illustration 510016 1 2 3 4 5 3 Components and spare parts 6 7 ...

Page 22: ...interrupt the main power supply Completely remove the screw connections on the casing remove the Eco Valve check the inlet strainer if required remove it and rinse with clear water replace if necessary Re assemble in reverse order Slowly re open water supply We recommend annual servicing intervals with our Caroma service technicians or a certified specialist Attention Potential material damage due...

Page 23: ...evel Press the button on the device to open the shut off valve It is possible to perform this action via the Smart Command App Suspected leak flow based leakage The maximum admissible flow rate has been exceeded Potential flow based leakage for instance due to a pipe burst Please eliminate the leakage or adjust the protection level Press the button on the device to open the shut off valve It is po...

Page 24: ...mperature sensor does not pass on any information maybe due to a defect Please contact Caroma service Fault Conductivity sensor The conductivity sensor does not pass on any information maybe due to a defect Please contact Caroma service BA battery replacement The batteries are spent Please replace the batteries Warning volume based leakage The limit value for volume based leakage has almost been r...

Page 25: ...col Bluetooth 4 0 Max operating pressure kPa 1400 Max ambient air temperature C 10 60 Operating temperature C 10 65 Room temperature C 5 50 Max motor torque Nm 2 Mains adapter Unit Value Inlet voltage V AC 240 Frequency Hz 50 60 Outlet voltage V DC 12 Power A 2 Class II double insulated Flow capacity DN 20 DN 25 DN 32 500 kPa 75 2 lpm 80 2 lpm 80 2 lpm 1000 kPa 106 9 lpm 121 9 lpm 128 6 lpm ...

Page 26: ...rt Command Intelligent Eco Valve 13 Dimensions 13 Dimensions Nominal size DN 20 DN 25 DN 32 A 1 1 H 118 8 mm 118 8 mm 118 8 mm h 39 mm 39 mm 39 mm L 265 2 mm 261 2 mm 285 2 mm l 191 2 mm 191 2 mm 191 2 mm B 79 5 mm 79 5 mm 79 5 mm ...

Page 27: ...27 ...

Page 28: ......