Motor Controllers AC Variable Frequency Drives
Type Variflex
3
RVFF
Specifications are subjected to change without notice.
95
(b)
11~15kW (15-20HP)
In compliance with the requirements of EN61800-3:2004+A1:2012(PDS of Category C2), the
enclosed ferrite core needs to be mounted on the configuration of inverter connected to the
motor cable and remote control box wire.
Installation position:
➢
Mounted on the inverter output terminal (U, V, and W) or motor cable.
Installation procedure:
➢
The motor cable is required to be passed through two ferrite ring cores, which are all placed
in the filter. Motor cable is passed through 1
st
core (orange) around 1 lap and through 2
nd
core (green) around 2 laps. Then it is connected to the inverter output terminal U, V and W.
Notes:
➢
The length of inverter output terminal wire or motor cable is suggested to be within 10