Car Park 3 – General installation
33
5.5 Cable for display unit to the display interface
Each DISxRSE car park display must be connected to a SBP2DI48524 display interface powered
by 24 V DC nominal.
The table below shows the devices with the relevant power consumption to be considered for
sizing the power supply unit:
Part number
Max. rated operational power
DISARSE
32 W
DISBRSE
53 W
DISCRSE
95 W
5.5.1 Connect the display to the SBP2DI48524 interface
Connect the display to the SBP2DI48524 module through a 4-wire cable:
SBP2DI48524 terminal DISxRSE wire colour Cable required
+24 V
Red
0.5 mm
2
or 20 AWG unshielded
GND
Black
0.5 mm
2
or 20 AWG unshielded
A (-)
White
1.0 mm
2
or 18 AWG unshielded
B (+)
Yellow
1.0 mm
2
or 18 AWG unshielded
Make sure the connection is correct!