Car Park 3 – General installation
32
Then each lane has to be divided into equal parts, called lines: lane 1 (with 4 lines: line 1, line 2, line
3 and line 4) and Lane 2 (with 2 lines: line 5 and line 6).
The cable lengths or number of loads (sensors) must not be exceeded when the modules are
connected to the CMCG (i.e., maximum 50 sensors and 150 m (490 ft) of wire in a line).
In the example below, the distance between the sensors is 3 m (9.8ft).
The small dots represent the wiring nodes and the black lines indicate the distance between the
CMCG to the 1
st
sensor of each line.
As shown in the table below, for all the lines the maximum limits are not exceeded:
Sensors/line
Cable length
between CMCG and
1
st
sensor (m)
Cable length between
1
st
sensor and the last
sensor (m)
Total cable length
(m)
Line 1
17
40
51
91
Line 2
11
5
33
38
Line 3
5
2
15
17
Line 4
14
40
42
82
Line 5
23
4
69
73
Line 6
36
7
108
115
LINE 1
LINE 2
LINE 3
LINE 4
LINE 5
LINE 6