WA R N I N G
!
WA R N I N G
!
START-UP
After all installation procedures are completed, operation
of the applicator may begin. When the ON-OFF switch is
turned on, the kV display will show the applicator type the
9060 Controller is configured for and the µA (microamp)
display will show the current software revision level as shown
in Figure 10. These items are displayed for approximately
10 seconds.
Figure 10: Controller Start-Up Display
The controller comes preconfigured for the No. 2 Process
Handgun (Air Motor) from the factory. The following table
lists the display value and jumper setting for the unit. This
table is a
reference
to verify that the gun configuration
jumpers are in their correct positions if unexpected behavior
is observed.
After the initial start-up delay, the unit will be configured for
the applicator based on the gun type jumper settings and
is ready for standard operation.
BASIC OPERATIONS
The basic operations are general operations that are
available.
Triggering
High voltage is actuated by the presence of an active trig-
ger signal. This is normally accomplished by pulling the
trigger of the No. 2 Process Handgun to start the flow of
air through the applicator. The flow of air activates the air
flow switch which sends a trigger signal to the 9060 unit.
The kV setpoint is displayed on the kV display, the actual
current draw on the µA display, and the high voltage light
illuminates. Under the µA display is a bar graph meter that
illuminates according to the actual current draw shown in
Figure 11.The green and yellow regions of the bar graphs
meter indicate output current is in the optimum range for
maximum transfer efficiency. The red region of the bar
graph indicates high output current causing decreased
transfer efficiency. If high output, check maintenance of
applicator and external equipment of the power supply.
90
No. 2 Handgun (Air Motor)
10, 11
DO NOT
adjust the gun configuration jumpers. If they
are incorrect, contact your Ransburg representative.
Type
Unit (Gun)
START-UP DISPLAY
Jumpers
USE ONLY
the gun type configuration for the No.
2 Process Handgun. Using the wrong configuration
may allow for operation outside the recommended
parameters and values for the applicator and can re-
sult in
damage
or
un-safe operation
.
OPERATION
NOTE
During start-up, the gun trigger should
NOT
be pressed. An active trigger signal will cause a
non-resettable boot fault (bF) and prevent the unit
from being operated. This is designed to prevent
unintended operation of the high-voltage immediately
after start-up. Please refer to the “Fault Section” of
this manual for more information.
GUN TYPE NUMBER
SOFTWARE REVISION LEVEL
ON-OFF SWITCH
CP-13-04.3 (10/2017)
18 / 29
www.carlisleft.com
OPERATION