Carimali DIVA COF Technical Instructions Download Page 5

LB.05099.02 

Pag. 5 

18/10/16 

MAIN FEATURES 

 
 

DIVA 

COF 

LM* 

Maximum quantity of coffee dispensed per hour 

480 

480 

Width (mm.) 

800

 

800

 

Height (mm.) 

574 

574 

Depth (mm.) 

515 

515 

Net weight (Kg.) 

70 

71 

Boiler capacity (lt.) 

11,5 

11,5 

Hot water nozzle 

Steam nozzle 

Barista steam wand 

Mix cold water for tea 

Automatic cappuccino LM maker optional 

Milk pump 

Boiler resistor (W) - Standard version 

4300 

4300 

Voltage 

220V-240V 

1+N  

60 Hz 

400V - 3+N 

50/60 Hz 

220V - 1+N  

60 Hz 

400V - 3+N 

50/60 Hz 

 
* LM version is only available with Hi groups 
 
 
Materials used: 
 

Copper for boiler and piping 

Teflon for the articulated feed tube 

reinforced silicone for the articulated pump tube 

low lead brass chromed for the brewing group 

brass for taps and connections 

metal and aluminum bodywork. 

 
Machine Equipment: (for 2 groups machine) 
 

 

1 Filter holder  1 outlet (with  7g - 0,2469 oz  filter) 

 

1 Filter holder  2 outlet  (with 14g - 0,4938 oz  filter)  

 

1 Filter  6 g - 0,2116 oz  

 

1 Coffee press 

 

1 Dose spoon 

 

1 Rubber blind filter 

 

1 Hose clamp (

Ø 

16 / 27

)

 

 

1 Drain armoured hose (Internal 

Ø

 16  - 1,5 m / 4,92 feet) 

 

1 Inlet armoured  pipe (

Ø

 3/8 G - 1,5 m / 4,92 feet) 

 

1 Brush 

 
 
Peripheral applications: 
 

-

 

Serial output RS 232 C for: 

-

 

I/O interface 26 relay 

 

 

Summary of Contents for DIVA COF

Page 1: ...LB 05099 02 Pag 1 18 10 16 DIVA LB 05099 02 EDITION OTTOBRE 2016...

Page 2: ...LIC CONNECTION 8 STARTING UP 9 ACCESS THE MAIN SETTING MENUS WITH PASSWORD 12 PROGRAMMABLE PARAMETERS IN ACCORDING WITH PASSWORD 13 INFO RESET 15 DOSES PROGRAMMING 18 DEFAULT DELIVERY SETTING 20 SYSTE...

Page 3: ...h situation Place the machine on a table having minimum height of 0 95mt Furthermore the surface has to be flat having a maximum inclination of 5 in order to secure a perfect stability Check also that...

Page 4: ...te points Do not leave the machine in rooms where the temperature is below 0 C or 32 F without having first drained the boiler and the hydraulic circuit Cups and coffee cups must be placed on the cup...

Page 5: ...rsion is only available with Hi groups Materials used Copper for boiler and piping Teflon for the articulated feed tube reinforced silicone for the articulated pump tube low lead brass chromed for the...

Page 6: ...he drip tray MACHINE KEYPAD Machine keypads DIVA COF 2GR Gr 1 keypad Gr 2 keypad 11 12 13 14 15 21 22 23 24 25 Key 11 1 Ristretto key Key 21 1 Ristretto key Key 12 2 Ristretto key Key 22 2 Ristretto k...

Page 7: ...esso key Key 23 1 Espresso key Key 14 2 Espresso key Key 24 2 Espresso key Key 15 1 Cappuccino key Key 25 1 Coffee key Key 16 1 Caff latte key Key 26 2 Coffee key Key 17 1 Latte macchiato key Key 27 1...

Page 8: ...LB 05099 02 Pag 8 18 10 16 ELECTRIC CONNECTION HYDRAULIC CONNECTION WATER SOFTNER WATER FILTER WATER DRAIN WATER TAP 1 6 BAR...

Page 9: ...display and master p c boards System clock programming YYYY MMM DD DAY HH MM Use keys to program the date YYYY MMM DD DAY and the time HH MM OFF A If the language choice is not displayed keep the mach...

Page 10: ...minutes the display shows 2015 FEB 16 TUE 04 54 FILLING UP BOILER PLEASE NOTE In case the display shows FILLING UP T O switch OFF and ON the machine by using the main switch I G If the display shows F...

Page 11: ...LL RELEASE THE AIR FROM THE BOILER COF Version DURING THIS STAGE KEEP THE STEAM LEVER OPEN FOR A FEW SECONDS THIS OPERATION WILL RELEASE THE AIR FROM THE BOILER Check the delivery pressure in the pump...

Page 12: ...t environments The password must be composed with 5 numbers To insert the passwords proceed as follows Turn the machine OFF Press The display shows INSERT PASSWORD Enter one of the following passwords...

Page 13: ...X Auto start up X X On Off X X Day Off X X SERVICE Milker clean Rinse Milker cleaning time X X Milker cleaning programming X Milker auto rinsing X Maintenance set up Water filter X Machine service X A...

Page 14: ...T ACTUATORS Actuators 1 X Actuators 2 X Actuators 3 X Actuators 4 X Milk pump X BOILER DRAINING Boiler draining X MACHINE CONFIGURATION Groups number X Barista nozzle X Milker X Milk pump X Cup warmer...

Page 15: ...umber of the key XXXXX Indicates the name of the selected key YY Indicates the number of cups dispensed Press to select the keys between B1 to B7 GR1 LM first dose keys menu B1 to B7 GR2 LM first dose...

Page 16: ...o reset System data Read doses data Read doses data Doses counter A Doses counter B Reset doses counter B Reset Doses counter A WITH THIS OPERATION WE RESET ONLY THE DOSES COUNT EXTRA MILK No Yes Rese...

Page 17: ...a Group 2 cleaning XX Group 2 cleaning Confirm reset Group 2 cleaning 0 No Yes Water filter XX Water filter Confirm reset Water filter X Yes No Group 1 cycles XX Group 1 cycles Confirm reset Group 1 c...

Page 18: ...onfirm the selection Use key Cut to delete a letter Use key Ins to insert a space After you selected the required name press Enter key the display shows GRX BX XXXXX PRE INFUSION X ml PAUSE X s Coffee...

Page 19: ...AMED MILK PRE XX s MILK PUMP SPEED XX XXXXX Drink name XX Time and percentage press to select GRX BX XXXXX FOAMED MILK PRE XX s MILK PUMP SPEED XX XXXXX Drink name XX Time and percentage press to sele...

Page 20: ...3 ml 3 ml 3 ml OFF Preinfusion s 2 s 2 s 2 s 2 s Steamed Milk pre Foamed Milk pre Pause Steamed Milk post Foamed Milk post Foamed Milk DRINK NAME KEY Caff Latte Cappuccino Latte Macchiato Water volum...

Page 21: ...MANAGER Press the key to confirm entering the desired environment Press the key to exit System manager System clock programming Service Alarm history Display regulation Machine parameters Change pass...

Page 22: ...art up ON OFF XX XX XX XX Day Off 1 OFF 2 OFF 3 OFF Press the keys to program the machine days off Sunday Monday etc It is possible to program maximum 3 days off Press the keys to program the automati...

Page 23: ...to program at what time the display will show group milker cleaning message It is possible to program 3 different times Stop drink selection T O Stop drink xx min If the time out xx min 0 180 of the...

Page 24: ...able Value Milker Clean Rinse Milker cleaning time Milker auto rinsing Milker cleaning programming Milker auto rinsing Milker Clean Rinse Milker cleaning time Milker cleaning programming Milker auto r...

Page 25: ...ore display the alarm Off 5000 L Press to program the annual clock rate Water filter maintenance Off 4 per year Next maintenance YYYY MM DD Press if you want change the maintenance day Service frequen...

Page 26: ...MM System manager System clock programming Service Display regulation Machine parameters Change password Test actuactors Boiler draining Machine configuration Preset configuration data Alarm history...

Page 27: ...e Coffee dose A B Xx min Additional coffee water Xx ml 2ml 10min Variable Value 0 60min 1 50ml With these two parameters it is possible to set an additional water amount for the first coffee dispensed...

Page 28: ...A B 2 min 0 60 min Additional milk 1 sec 1 10 sec Variable Value Milk pump time pre 1 0 Sec Milk pump speed XX Milk pump time post 1 5 Sec Milk pump speed XX 0 10 Sec 0 10 Sec Alarm detail Enable Disa...

Page 29: ...LB 05099 02 Pag 29 18 10 16 Installation date YY MM DD Press to modify the machine installation date Serial number XXXXXX Set the serial number of the machine Cup warmer temperature 60 C 45 70 C...

Page 30: ...want to change Use the dose key to modify the password see the drawing below PLEASE NOTE THE FIRST DIGIT OF THE PASSWORDS CAN NOT BE MODIFY System manager System clock programming Service Alarm histor...

Page 31: ...parameters Change password Boiler draining Machine configuration Preset configuration data Test actuators Test actuators Actuators 2 Actuators 3 Actuators 4 Milk pump Actuators 1 Test actuators B1 Wa...

Page 32: ...3 Milk pump Actuators 4 Test actuators B1 Steam milker S V B2 Air milker S V B4 Rinse milker S V B6 Steam nozzle S V xx C B7 Nozzle air S V Press a dose keys between B1 to B7 to activate the actuator...

Page 33: ...manager System clock programming Service Alarm history Display regulation Machine parameters Change password Test actuators Machine configuration Preset configuration data Boiler draining CLOSE THE I...

Page 34: ...et configuration data Machine configuration Machine configuration Barista nozzle XXXXX Machine configuration Milker XXXXX Enable Disable Enable Disable Use keys to enable or disable the Milker Use key...

Page 35: ...ll be reseted all parameters included the Machine Configuration parameters The Technician or Factory preset can be carried out only with Technician password With Service password can be carried out on...

Page 36: ...e the pump by turning the adjustment clockwise to increase the pump pressure or anticlockwise to reduce pressure Once the adjustment is completed test the pressure calibration by dispensing one or mor...

Page 37: ...ase there is not way to preset the machine via the standard procedure follow the following instructions Before starting the procedure disconnect the boiler temperature probe To do that disconnect eith...

Page 38: ...cedure in relevant manual LB 00145 2 DISPLAY PCB If the machine has release V1 05A or lower you have to first install the BOOTLOADER by using ST LINK programmer and ten upgrade software by following p...

Page 39: ...ly for machine whit software V1 06 or higher 2 2 1 Now pick and USB key and format in FAT file type you can control in propriety of Your USB Key 2 2 2 Now open the USB Key and create a folder folder n...

Page 40: ...o USB cable just like in the photo on the left If you need this type of cable the code is 96 05411 Turn on the machine then the new software Will be automatically uploaded During this phase the displa...

Page 41: ...r heating is interrupted and all dose buttons are disabled Solution turn OFF the machine Replace the temperature probe Turn the machine ON Third case the temperature probe is defective The probe sends...

Page 42: ...delivery Solution carry out the following controls 1 Steam probe is earthen 2 Steam probe is disconnected 3 Faulty control unit 6 GRX TEMPERATURE 49 50 GRX TEMPERATURE This alarm is visualized on dis...

Page 43: ...warmer temperature of the heating element is not warming up Result Cold cup warmer Solution carry out the following controls 1 Heating element disconnected 2 Faulty heating element 3 Faulty control u...

Page 44: ...ancel the alarm following the procedure of the chapter Info reset 12 CORRUPTED DATA 60 CORRUPTED DATA This alarm is visualized on display by code 60 First case This alarm is visualized during machine...

Page 45: ...ng way Replace filter holder gasket every 3 6 months Replace the steam water valve gasket every 6 months Replace the steam nozzle joint gasket every 6 12 months To reach the pump the boiler heater and...

Page 46: ...equipment illustrated in this publication the manufacturer declines all responsibility for any mistakes due to printing and or typing errors contained in this publication All instructions drawings tab...

Reviews: