INTRODUCTION AND GENERAL NOTES 

 

Thoroughly  read  the  instructions contained in this  booklet  because  it  gives  important information  regarding  safety  for  installation,  use and 
maintenance. 
Keep this booklet in a safe and accessible place for further consultation. 
This machine must be used only for the purpose it was designed: 
dispensing coffee, cappuccino, pouring hot water. 
Any other use is to be considered inappropriate and therefore dangerous. 
The manufacturer declines all responsibility for damage caused by any improper, incorrect and unreasonable use of the machine. 
 
The use of any electric appliance implies the observance of some fundamental rules. 
More specifically: 

 

The  appliance  should  be  placed  on  a  stable  flat  surface  with  the  bodywork  at  a  minimum  distance  of  20mm  from  the  back  wall, 
furthermore, it must be installed taking into account that the highest shelf must sit at a height that is at least 1.5 mt. 
During installation, fit a device that guarantees disconnection from the mains, duly sized according to the power of the equipment (see 
rating plate), as well as protection against leakage current with a value equal to 30mA.This cut-off device must be assembled on the 
power supply line in compliance with installation rules. 

 

do not touch the appliance with your hands or feet wet or damp 

 

do not use the appliance with bare feet 

 

do not pull the power cord to disconnect the plug from the power socket 

 

dot not leave the appliance exposed to the weather (rain, sun, frost) 

 

do not let children or untrained persons use the appliance. 

 
Before carrying out any cleaning and maintenance, disconnect the appliance from the power supply, pulling the plug from the power socket 
and turning off the main switch. 
In case of failure or malfunction turn the machine off and do not attempt to carry out any repairs or direct operations on the machine. 
All repairs must be carried out in an authorized service centre, using original spare parts only. 
Failure to comply with the above recommendations will compromise the safety of the machine and the warranty conditions. 
If  this  machine  is  no  longer  used  we  recommend  that  it  is  made  inoperative  by  disconnecting  the  cable  from  the  power  supply,  and  all 
potentially dangerous parts are made harmless, especially to protect children who might use the machine for their games. 
 

INSTALLATION NOTES 

 
Installation must be carried out according to the manufacturer’s instructions. 
An incorrect installation can cause damage to persons, animals or things; the manufacturer declines all responsibility for such situation. 
Place the machine on a table having minimum height of 0,95mt. Furthermore the surface has to be flat, having a maximum inclination of 5°, 
in order to secure a perfect stability. Check also that the table can bear the weight of the machine. 
This is a commercial machine and is not designed for home use and must be operated by duly qualified persons.  
The machine must not be used by children or people with reduced mobility, sensory, mental or lack of experience or education, unless there 
is a supervisor. 
After unpacking check that the machine is not damaged. 
If in doubt, do not use the machine and contact an Carimali Authorized Service Centre. 
All 

packing  materials  (plastic  wrapping,  polystyrene,  nails,  etc.)  are  potentially  dangerous  and  must  be  kept  out  of  children’s  reach  and 

disposed of in a safe manner for the environment. 
Before connecting the machine to the power supply make sure that the rating information of the machine correspond to that of the power 
supply, and that the power supply is adequate to additional power absorption of the machine. 
The machine is supplied with power cord and without plug, connect the machine to the main switch with knife switch and protection fuses. In 
case of maintenance, open the knife switch. 

 
 
                      The machine with single phase voltage, having a rated current more than 16A,

 

must be connected to power supply with a dedicated  

                      impedance. 
 

The  electrical  safety  of  this  machine  can  be  guaranteed  only  if  correctly  connected  to  an  efficient  earth  circuit  as  indicated  by  current 
electrical safety regulations. 
It  is  necessary  to  check  this  fundamental  safety  prerequisite,  and  in  case  of  doubt,  ask  a  professionally  qualified  technician  to  check  the 
circuit. 
The manufacturer declines all responsibility for any damage caused by failure to earth the equipment. 
 
In order to avoid any dangerous overheating, we recommend that the power cord be fully unwound. 
In case of damage to the cord, contact exclusively an authorized service centre to have it replaced. 
The power cord of this machine must not be replaced by the customer. 
Do not leave the machine connected unnecessarily. 
Turn off the main switch of the machine when not in use. 
Do not cover the ventilation openings of the machine. 
Place the machine at an adequate distance from walls, objects, etc. 
The  machine  must  be  connected  to  a  system  with  a  water  pressure  which  is  not  greater  than  0.6  MPa.  Do  not  use  pipes  and  coupling 
gaskets already used for previous installations. 
If the pressure is greater, a pressure reducer must be installed. 
The machine must be connected to a softener. 
 
ENVIRONMENTAL CONDITIONS TO USE THE MACHINE 
Environmental temperature:           5 

– 30 °C (empty the hydraulic system in case of freezing) 

Maximum humidity:                        80% relative humidity 
Water hardness:                             5° eh, 7° dH, 13° Fh 
 
 

 

Summary of Contents for DIVA COF

Page 1: ...LB 05099 02 Pag 1 18 10 16 DIVA LB 05099 02 EDITION OTTOBRE 2016...

Page 2: ...LIC CONNECTION 8 STARTING UP 9 ACCESS THE MAIN SETTING MENUS WITH PASSWORD 12 PROGRAMMABLE PARAMETERS IN ACCORDING WITH PASSWORD 13 INFO RESET 15 DOSES PROGRAMMING 18 DEFAULT DELIVERY SETTING 20 SYSTE...

Page 3: ...h situation Place the machine on a table having minimum height of 0 95mt Furthermore the surface has to be flat having a maximum inclination of 5 in order to secure a perfect stability Check also that...

Page 4: ...te points Do not leave the machine in rooms where the temperature is below 0 C or 32 F without having first drained the boiler and the hydraulic circuit Cups and coffee cups must be placed on the cup...

Page 5: ...rsion is only available with Hi groups Materials used Copper for boiler and piping Teflon for the articulated feed tube reinforced silicone for the articulated pump tube low lead brass chromed for the...

Page 6: ...he drip tray MACHINE KEYPAD Machine keypads DIVA COF 2GR Gr 1 keypad Gr 2 keypad 11 12 13 14 15 21 22 23 24 25 Key 11 1 Ristretto key Key 21 1 Ristretto key Key 12 2 Ristretto key Key 22 2 Ristretto k...

Page 7: ...esso key Key 23 1 Espresso key Key 14 2 Espresso key Key 24 2 Espresso key Key 15 1 Cappuccino key Key 25 1 Coffee key Key 16 1 Caff latte key Key 26 2 Coffee key Key 17 1 Latte macchiato key Key 27 1...

Page 8: ...LB 05099 02 Pag 8 18 10 16 ELECTRIC CONNECTION HYDRAULIC CONNECTION WATER SOFTNER WATER FILTER WATER DRAIN WATER TAP 1 6 BAR...

Page 9: ...display and master p c boards System clock programming YYYY MMM DD DAY HH MM Use keys to program the date YYYY MMM DD DAY and the time HH MM OFF A If the language choice is not displayed keep the mach...

Page 10: ...minutes the display shows 2015 FEB 16 TUE 04 54 FILLING UP BOILER PLEASE NOTE In case the display shows FILLING UP T O switch OFF and ON the machine by using the main switch I G If the display shows F...

Page 11: ...LL RELEASE THE AIR FROM THE BOILER COF Version DURING THIS STAGE KEEP THE STEAM LEVER OPEN FOR A FEW SECONDS THIS OPERATION WILL RELEASE THE AIR FROM THE BOILER Check the delivery pressure in the pump...

Page 12: ...t environments The password must be composed with 5 numbers To insert the passwords proceed as follows Turn the machine OFF Press The display shows INSERT PASSWORD Enter one of the following passwords...

Page 13: ...X Auto start up X X On Off X X Day Off X X SERVICE Milker clean Rinse Milker cleaning time X X Milker cleaning programming X Milker auto rinsing X Maintenance set up Water filter X Machine service X A...

Page 14: ...T ACTUATORS Actuators 1 X Actuators 2 X Actuators 3 X Actuators 4 X Milk pump X BOILER DRAINING Boiler draining X MACHINE CONFIGURATION Groups number X Barista nozzle X Milker X Milk pump X Cup warmer...

Page 15: ...umber of the key XXXXX Indicates the name of the selected key YY Indicates the number of cups dispensed Press to select the keys between B1 to B7 GR1 LM first dose keys menu B1 to B7 GR2 LM first dose...

Page 16: ...o reset System data Read doses data Read doses data Doses counter A Doses counter B Reset doses counter B Reset Doses counter A WITH THIS OPERATION WE RESET ONLY THE DOSES COUNT EXTRA MILK No Yes Rese...

Page 17: ...a Group 2 cleaning XX Group 2 cleaning Confirm reset Group 2 cleaning 0 No Yes Water filter XX Water filter Confirm reset Water filter X Yes No Group 1 cycles XX Group 1 cycles Confirm reset Group 1 c...

Page 18: ...onfirm the selection Use key Cut to delete a letter Use key Ins to insert a space After you selected the required name press Enter key the display shows GRX BX XXXXX PRE INFUSION X ml PAUSE X s Coffee...

Page 19: ...AMED MILK PRE XX s MILK PUMP SPEED XX XXXXX Drink name XX Time and percentage press to select GRX BX XXXXX FOAMED MILK PRE XX s MILK PUMP SPEED XX XXXXX Drink name XX Time and percentage press to sele...

Page 20: ...3 ml 3 ml 3 ml OFF Preinfusion s 2 s 2 s 2 s 2 s Steamed Milk pre Foamed Milk pre Pause Steamed Milk post Foamed Milk post Foamed Milk DRINK NAME KEY Caff Latte Cappuccino Latte Macchiato Water volum...

Page 21: ...MANAGER Press the key to confirm entering the desired environment Press the key to exit System manager System clock programming Service Alarm history Display regulation Machine parameters Change pass...

Page 22: ...art up ON OFF XX XX XX XX Day Off 1 OFF 2 OFF 3 OFF Press the keys to program the machine days off Sunday Monday etc It is possible to program maximum 3 days off Press the keys to program the automati...

Page 23: ...to program at what time the display will show group milker cleaning message It is possible to program 3 different times Stop drink selection T O Stop drink xx min If the time out xx min 0 180 of the...

Page 24: ...able Value Milker Clean Rinse Milker cleaning time Milker auto rinsing Milker cleaning programming Milker auto rinsing Milker Clean Rinse Milker cleaning time Milker cleaning programming Milker auto r...

Page 25: ...ore display the alarm Off 5000 L Press to program the annual clock rate Water filter maintenance Off 4 per year Next maintenance YYYY MM DD Press if you want change the maintenance day Service frequen...

Page 26: ...MM System manager System clock programming Service Display regulation Machine parameters Change password Test actuactors Boiler draining Machine configuration Preset configuration data Alarm history...

Page 27: ...e Coffee dose A B Xx min Additional coffee water Xx ml 2ml 10min Variable Value 0 60min 1 50ml With these two parameters it is possible to set an additional water amount for the first coffee dispensed...

Page 28: ...A B 2 min 0 60 min Additional milk 1 sec 1 10 sec Variable Value Milk pump time pre 1 0 Sec Milk pump speed XX Milk pump time post 1 5 Sec Milk pump speed XX 0 10 Sec 0 10 Sec Alarm detail Enable Disa...

Page 29: ...LB 05099 02 Pag 29 18 10 16 Installation date YY MM DD Press to modify the machine installation date Serial number XXXXXX Set the serial number of the machine Cup warmer temperature 60 C 45 70 C...

Page 30: ...want to change Use the dose key to modify the password see the drawing below PLEASE NOTE THE FIRST DIGIT OF THE PASSWORDS CAN NOT BE MODIFY System manager System clock programming Service Alarm histor...

Page 31: ...parameters Change password Boiler draining Machine configuration Preset configuration data Test actuators Test actuators Actuators 2 Actuators 3 Actuators 4 Milk pump Actuators 1 Test actuators B1 Wa...

Page 32: ...3 Milk pump Actuators 4 Test actuators B1 Steam milker S V B2 Air milker S V B4 Rinse milker S V B6 Steam nozzle S V xx C B7 Nozzle air S V Press a dose keys between B1 to B7 to activate the actuator...

Page 33: ...manager System clock programming Service Alarm history Display regulation Machine parameters Change password Test actuators Machine configuration Preset configuration data Boiler draining CLOSE THE I...

Page 34: ...et configuration data Machine configuration Machine configuration Barista nozzle XXXXX Machine configuration Milker XXXXX Enable Disable Enable Disable Use keys to enable or disable the Milker Use key...

Page 35: ...ll be reseted all parameters included the Machine Configuration parameters The Technician or Factory preset can be carried out only with Technician password With Service password can be carried out on...

Page 36: ...e the pump by turning the adjustment clockwise to increase the pump pressure or anticlockwise to reduce pressure Once the adjustment is completed test the pressure calibration by dispensing one or mor...

Page 37: ...ase there is not way to preset the machine via the standard procedure follow the following instructions Before starting the procedure disconnect the boiler temperature probe To do that disconnect eith...

Page 38: ...cedure in relevant manual LB 00145 2 DISPLAY PCB If the machine has release V1 05A or lower you have to first install the BOOTLOADER by using ST LINK programmer and ten upgrade software by following p...

Page 39: ...ly for machine whit software V1 06 or higher 2 2 1 Now pick and USB key and format in FAT file type you can control in propriety of Your USB Key 2 2 2 Now open the USB Key and create a folder folder n...

Page 40: ...o USB cable just like in the photo on the left If you need this type of cable the code is 96 05411 Turn on the machine then the new software Will be automatically uploaded During this phase the displa...

Page 41: ...r heating is interrupted and all dose buttons are disabled Solution turn OFF the machine Replace the temperature probe Turn the machine ON Third case the temperature probe is defective The probe sends...

Page 42: ...delivery Solution carry out the following controls 1 Steam probe is earthen 2 Steam probe is disconnected 3 Faulty control unit 6 GRX TEMPERATURE 49 50 GRX TEMPERATURE This alarm is visualized on dis...

Page 43: ...warmer temperature of the heating element is not warming up Result Cold cup warmer Solution carry out the following controls 1 Heating element disconnected 2 Faulty heating element 3 Faulty control u...

Page 44: ...ancel the alarm following the procedure of the chapter Info reset 12 CORRUPTED DATA 60 CORRUPTED DATA This alarm is visualized on display by code 60 First case This alarm is visualized during machine...

Page 45: ...ng way Replace filter holder gasket every 3 6 months Replace the steam water valve gasket every 6 months Replace the steam nozzle joint gasket every 6 12 months To reach the pump the boiler heater and...

Page 46: ...equipment illustrated in this publication the manufacturer declines all responsibility for any mistakes due to printing and or typing errors contained in this publication All instructions drawings tab...