10) CHANGE WATER FILTER
90 CHANGE WATER
FILTER
This alarm is visualized on display by code 90
Cause: the flowmeter has reached the maximum value of XXXXX litres of previously programmed water, which may be
dispensed.
Result: none.
Solution: renew the softener salts. To cancel the alarm, see the Info -Reset paragraph for further information.
Note: this alarm does not block dispensing. The softener alarm can be excluded by setting the litre value to zero (see Service
–
Maintenance set-up paragraph).
11) MAINTENANCE
92 MAINTENANCE
This alarm is visualised on display by code 92
Cause: the machine has reached the number of programmed cycles or the inspection date (see Service chapter).
Result: none.
Solution: check or/and replace the wear parts and cancel the alarm following the procedure of the chapter Info reset.
12) CORRUPTED DATA
60 CORRUPTED DATA
This alarm is visualized on display by code 60
First case:
This alarm is visualized during machine functioning
Cause: incorrect operating data in machine memory.
Result: machine shutdown.
Solution: carry out the following controls.
1)
Verify programming data relevant to the operation that is being carried out. They might be varied and therefore the
machine does not recognise the new data.
2)
Carry out “PARAMETERS PRESET” procedure (see chapter system programming configuration data preset).
Second case:
software programming values or data incorrect, data inserted by means of P.C. programming incorrect.
Result: machine shutdown.
Solution:
1)
Carry out “PRESET CONFIGURATION DATA” procedure
2)
Insert new software by means of P.C.
13) CLOCK ERROR
63 CLOCK ERROR
This alarm is visualized on display by code 63
Solution: check the following:
a)
run down battery
b)
faulty master board