Carico ULTRA TECH CLEAN MACHINE Manual Download Page 7

EN

7

2

1

4

3

3.2 SAFETY FEATURES

3.2.1. Mechanical safety features:

  The safety pressure valve exit is located on the bottom of the machine, and 

 

releases steam if the pressure inside gets too high. The steam is released

 

underneath the device to avoid harming anyone. The working pressure 

 

in the boiler is 5.5 Bar (80 psi) and the safety valve will only open within a 

 

range of m2 Bar (29 psi).  

  The unit has 2 INCOLOY 800 heat coils which are extremely resistant 

 

to high temperatures and against limestone deposits.

  Intake and outtake air for the vacuum motor are kept in separate 

 directions 

to keep the motor cool.

3.2.2. Electric safety features:

  The boiler has a pressure sensor which guarantees that it maintains 

 

pressure around 5.5 Bar (80 psi). 

  The multi pin construction of the power cord means that by simply 

 

inserting the plug, a special sequence ensures that electricity properly 

 

passes the commands to the hose.

  If the sequence is correct, the unit will begin operating. If something is 

 

wrong, the unit will not operate. A resistor in the command center 

 

responds within a very small tolerance range that your accessory is 

 

properly connected and will not recognize a foreign accessory or object. 

  The self check takes approximately 7 seconds pass (delay) prior to  

 

 

freeing the electric circuit.

3.3 TECHNICAL DATA

 

    

Data plate characteristics  

    

WARNING! Make sure the technical data on the data plate matches that of 

your electricity system.

TECHNICAL CHARACTERISTICS

Boiler Power (1050+1050 W) / (1000+750 W)
Motor Vacuum Power 1200 W Higher technology gives 

same power as 1600 W motor but: Quieter, lower energy 

consumption, higher reliability and higher air volume.
Steam Pressure
Steam Flow
Max. steam Temperature in the Boiler
Effective Air flow
Vacuum pressure
Time of heating after turning on the steam to reach 

peak dry steam, just a few seconds with refill
Boiler Volume
Boiler Capacity
Recovery Tank Volume
Lengh of Flexible Tube (Hose)
Working Reach 
Lengh of Power Lead
Working Noise

Safety heat insulation extension tubes: 

Separate tubes for 1 steam and 2 vacuuming, 

outer tube protects from burning and 

isolates the electric part 4.

Safety features: 

      

  Safety thermostat: 170 °C (338 °F) 

 

 

 

  Boiler safety valve: 7 bar +/- 0.5 (101 psi +/- 7.2 psi)

 

Extra-low voltage handle commands: 5 Volt

   Heat insulation in extension tubes

   Steam safety lock

Patented 

systems: 

      

 

ULTRA FILTRATION SYSTEM

TM

     

• 

CARICONECT SYSTEM

TM

 

     

• 

CARICO'S SDP

TM

• 

RAIN SILVER SYSTEM (RSS)

• 

INTELLIGENT BOILER TECHNOLOGY

Product code: STM110 / STM220 

 

 

 

 

• 

Weight: 9.7 kg (21.4 lbs) 

 

 

 

 

 

• 

Size: 336x332x479 mm

230 VOLTS

2100 W

1200 W

5.5 Bar 

(550 kPa)

55 g/min

159 C / 318 F

23.51 l/sec

2290 mm H2O

4 min

0.8 Liters
0.5 Liters
1.2 Liters

2.0 M
8.0 M
5.0 M

71 DB(A)

120 VOLTS

1750 W

1200 W

5.5 Bar 

(550 kPa)

1.94 oz/min

318 F

23.51 l/sec

2290 mm H2O

6 min

0.21 Gallon
0.13 Gallon
0.32 Gallon

6.56 ft

26.24 ft
16.40 ft

71 DB(A)

Summary of Contents for ULTRA TECH CLEAN MACHINE

Page 1: ......

Page 2: ...e 11 5 2 Preparing the Boiler for steam cleaning ironing humidification page 11 6 OPERATION page 12 6 1 Vacuuming Wet Dry with Water filter page 12 6 2 Steam Cleaning Disinfection page 12 6 3 Steam Cl...

Page 3: ...y Vapor CARICO S COMPLETE SANITIZING SYSTEM is a high temperature vapor steam cleaner meaning it has approximately 5 6 moisture content in its steam Other less efficient products on the market have a...

Page 4: ...ccessory 14 16 26 Small Nozzle 16 17 26 Small Round Brush 16 17 26 Triangular Brush with Single and Triple Steam Jet 17 26 Duster Brush 17 26 Funnel for filling the Boiler Tank 17 Cobra Brush 17 18 26...

Page 5: ...nnect Do not let the power cord touch hot surfaces Wrap the power cord around the posts that are positioned in the rear of the CARICO COMPLETE SANITIZING SYSTEM when not in use Do not allow the power...

Page 6: ...liable for incidental or consequential damages to anyone of any nature whatsoever Some states provinces do not permit the exclusion or limitation of incidental or consequential damages so the above m...

Page 7: ...a plate characteristics WARNING Make sure the technical data on the data plate matches that of your electricity system TECHNICAL CHARACTERISTICS Boiler Power 1050 1050 W 1000 750 W Motor Vacuum Power...

Page 8: ...ped with the exclusive ULTRA FILTRATION SYSTEMTM a sophisticated system of filtration using highly efficient nebulized water cloud like which captures even the finest particles by binding them to the...

Page 9: ...llated water is not suitable for this appliance and its use can result in the product malfunctioning If tap water is hard we recommend using a mixture of half tap water and half distillated water in o...

Page 10: ...the hose is attached and the unit is connected to a power source the blue steady light will light up to signal that the machine is powered The tank lid fasteners are designed so that if they are hit w...

Page 11: ...TIZING To use the steam function press the steam function button to switch on the boiler Pict 11 The steam blue light will start flashing to signal that the boiler is building up pressure As the right...

Page 12: ...irst You can start vacuuming directly For best results use the following Medium speed large amounts of liquids e g a siphon High speed small amounts of liquids Intelligent Boiler Technology IBT The Ca...

Page 13: ...tank is clean Refill the tank with clean water as described in Chapter 6 adding 1 liter 0 26 gal of water Add a few drops of Carico approved concentrated fragrance to the water Pict 2 Only use Carico...

Page 14: ...brush into place Picts A C The brush is equipped with four handy grippers to attach a cloth if required It also has a slider for locking the joint The swivel joint allows for easy use even in tight sp...

Page 15: ...r attempt to use this accessory with steam GENERAL USE Very dirty surfaces First use an attachment with the bristles without steam to remove most of the dirt then use the steam allow the steam time to...

Page 16: ...inks Wash basin bidet toilet shower bath Taps and fittings to remove scale First treat the area with steam Stop the steam and switch to vacuum with the nozzle For cleaning radiators use steam the dust...

Page 17: ...tab is facing the back of the Cobra Brush Pict 1 Rotate the attachment Pict 2 and snap it into place Pict 3 7 7 3 LARGE COBRA BRUSH Optional An optional Large Cobra Brush is available The Large Cobra...

Page 18: ...ict 1 7 8 WINDOW CLEANING Window glass or smooth surface cleaning is easy using the Cobra Brush with the squeegee In winter pre heat the windowpanes using steam at a 3 to 4 inch distance before procee...

Page 19: ...the efficiency of filter when you are cleaning the purification tank To do this remove and rinse the filter repeatedly separating it from the cover and the machine body Pict 1 Use small pliers eyebrow...

Page 20: ...m an authorized Carico Service Center Do not use the CARICO S COMPLETE SANITIZING SYSTEM without it Allow all pieces to dry or dry them yourself before replacing them in the machine and closing the co...

Page 21: ...r and boiler We advise you against using water with hardness exceeding 300 grams f French degrees 30 grains Proceed as follows finish off cleaning and wait for the machine to cool down completely Do n...

Page 22: ...You could chemically damage the sensor s surface Leave the product or the white non distilled vinegar to act on the sensor for at least 2 hours Pict 16 Fasten the sensor back onto the machine by turni...

Page 23: ...nable period of time free of any charge for the necessary parts and labor other than any applicable shipping handling and processing fees as expressly set forth herein to complete the repair and resto...

Page 24: ...CARICO SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IF CARICO CANNOT LAWFULLY DISCLAIM OR EXCL...

Page 25: ...is coming in where it should not Check that the cover hose and accessories are correctly mounted and fastened The seal along the water bucket is not properly positioned Correctly reposition the seal...

Page 26: ...t accessory 1 2 Liquid accessory 1 3 Floor accessory 2 Carrier for accessories Dress fit Single Jet 2 1 Small Nozzle 2 3 Small round Brushes 3 Cobra Brush 3 1 Liquid accessory with rubber squeegee for...