7.4 Expansion board with 4 relays
(accessory)
Inputs-outputs
Terminal Meaning
SUPPLY EXP
power supply connector (connect by 2-wire cable
to the main board)
EXP
MasterAria input signal connector(use 5-wire
cable)
N
neutral
No4 multifunction
voltage output (L)
No5 multifunction
voltage output (L)
No6
voltage free contact
No7
voltage free contact
Tab. 7.h
Maximum cable lengths for voltage outputs No4 & No5: 5 m
Maximum cable lengths for outputs No6 & No7: 30 m (as voltage-free
contact), 5 m (as control signal to power any load).
Technical specifi cations
Power supply
230 Vac, range –15 to +10%; 50/60 Hz; maximum power input: 1.5 VA
Screw termninals
max voltage: 230 V
cable cross-section: 14-22 AWG
the current input from the mains (sum of the current inputs of the loads, the main board, the expansion and
the external module) must not exceed 6 A.
0 to 10 Vdc outputs No4, No5
minimum impedance of the 0 to 10 Vdc actuator input stage (damper, valve,…): 10 KOhm
Relay outputs No4, No5, No6, No7
maximum current at 250 Vac: - EN60730: resistive 2 A, inductive: 2 A cos(j)=0.4 60000 cycles
type of relay action-microswitching: 1C
For the voltage outputs No4 and No5 respect the maximum limits described in the fi eld “screw terminals”.
minimum interval between switching cycles (each relay): 12 s (the manufacturer of the unit that the device is
integrated into must guarantee the correct confi guration to respond to this specifi cation)
type of relay action-microswitching: 1C
Insulation
insulation between low (relay outputs) and very low voltage parts: reinforced
insulation between outputs with voltage signal No4, No5 and outputs No6, No7: reinforced
insulation between outputs No6 and No7: reinforced.
If using serial boards, output No7 can be limited to very low voltage only. See the user manual.
Index of protection
IP00
Storage conditions
-20T80 °C, humidity 80% rH non-condensing
Operating conditions
0T60 °C, humidity <90% rH non-condensing
Pollution normal
Category of resistance to heat and fi re
D
PTI of the insulating materials
for all materials PTI≥250
Period of electrical stress
across the insulating parts
long
Tab. 7.i