+0300085EN rel. 2.2 - 07.05.2019
2.3 12-16 A single-phase, 18-24 A three-
phase inverter
For further details on the electrical and mechanical specifi cations, see
technical leafl et +0500048IE
C
1
C2
L1
/
L L
2/N
L
3
U
V
W
1
2 3 4 5 6 7 8 9
1
0
E
F
Fig. 2.d
Description of the terminals:
Ref.
Description
L1/L, L2/N, L3
Three-phase power input
earth conn. (*)
L1/L, L2/N
Single-phase power input
earth conn. (*)
U, V, W
Motor output
earth conn. (*)
C1, C2
Terminals not used in PSD10**2 **, for optional DC choke on
PSD10184** and PSD10244**
1.2
Relay output
3
0 V
RS485/ModBus® connection
4
Tx/Rx+
5
Tx/Rx-
6
PTC input
7
24 Vdc
Auxiliary voltage
8
0V
9
STOa
Safety digital input - Safe Torque
Off (**)
10
STOb
E
PE
F (LED)
POWER (green)
drive powered
RUN/FAULT (green/red)
drive running / active alarm
DATA (yellow)
communication active
(*) The earth connections inside the controller are electrically connected together
and to the PE.
(**) To enable the drive to operate, apply a voltage of 24 Vac/Vdc to the Safe Torque
Off digital input. The polarity is indiff erent for direct current power supply.
Main technical specifi cations
Reference technical docu-
ment
+0500048IE
Operating temperature
-20T60°C
Humidity
< 95% RH non-condensing
Environmental pollution level Max 2
Input voltage
200 - 240V ± 10%, 50 - 60Hz, 1~
Output voltage
0 - Input voltage
Output frequency
0 - 500 Hz
Maximum length
5 m
Switching frequency
4, 6, 8 kHz
Protection functions
Drive:
short circuit, overcurrent, earth fault, over-
voltage and undervoltage, overtemperature
Motore:
overtemperature and overload (150%
Inom for 1 minute)
System:
Safe Torque OFF input, loss of communi-
cation
Frequency resolution
0.1 Hz
Inputs
1 motor protection input: PTC temp. or volt-
age-free contact, maximum current 10 mA,
maximum length 25 m.
Outputs
1 relay: programmable output, voltage-free con-
tact: 240 Vac, 1 A
Serial input
RS485, Modbus® protocol, max baud rate 19200
bit/s
24 Vdc aux. power supply
Double insulation, 10% precision, 50 mA max
Maximum length
100 m shielded cable
Ingress protection
IP20
Tab. 2.e
CE conformity:
2006/95/EC
EN 61800-5-1: Adjustable speed electrical power drive systems. Safety require-
ments. Electrical, thermal and energy.
2004/108/EC
EN 61800-3, ed. 2.0: Adjustable speed electrical power drive systems. EMC require-
ments, including specifi c test methods.
EN61000-3-2: Electromagnetic compatibility (EMC) Part 3-2: Limits for harmonic
current emissions (equipment input current <= 16A per phase).
EN61000-3-12: Electromagnetic comp. (EMC) Part 3-12: Limits - Limits for harmonic
current emissions (equipment input current > 16A and <=75A per phase).
Rated values
The following table shows the rated input current and output current
values, as well as the specifi cations for sizing the cables (cross-section,
maximum length) and the fuses. The values refer to an operating
temperature of 60°C and a switching frequency of 8 kHz, unless otherwise
specifi ed.
model
PSD10122A0 PSD10162A0
Rated input current at 230 V
22 A
28 A
Fuse or type B circuit breaker
32 A
40 A
Power cable size
4 mm
2
6 mm
2
Rated output current
12 A
16A
Rated output power at 230 V
4.5 kW
6 kW
Maximum total dissipation
330 W
450 W
Maximum dissipation on the heat sink
190 W
250 W
Min. motor cable size
2.5 mm
2
2.5 mm
2
Max. motor cable length
5 m
5 m
Tab. 2.f
model
18A 3PH
24A 3PH
Rated input current at 400 V 3PH
23 A
30 A
Fuse or type B circuit breaker
32 A
40 A
Power cable size
4 mm
2
6 mm
2
Rated output current
18A
24A
Rated output power at 400 V 3PH
10.5 kW
14 kW
Maximum total dissipation
320 W
485 W
Maximum dissipation on the heat sink
250 W
380 W
Min. motor cable size
4 mm
2
4 mm
2
Max. motor cable length
5 m
5 m
Tab. 2.g
Dimensions
26
26
75
M5
127
131
86
82
26
60
70,8
190
268
240
289,2
71,3
12
27,9
24,6
24,6
33,2
173
80
192,3
Fig. 2.e
Summary of Contents for Hecu CO2
Page 2: ......
Page 4: ...4 ENG Hecu CO2 0300085EN rel 2 2 07 05 2019...
Page 6: ......
Page 61: ...61 ENG Hecu CO2 0300085EN rel 2 2 07 05 2019 9 2 Software revision history New version 3 0 012...
Page 62: ...62 ENG Hecu CO2 0300085EN rel 2 2 07 05 2019 Notes...
Page 63: ......