![Carefree ECLIPSE 2015 Service Manual Download Page 17](http://html.mh-extra.com/html/carefree/eclipse-2015/eclipse-2015_service-manual_2557094017.webp)
Carefree of Colorado Service
Manual
E
CLIPSE
052547-301r10
13
S
TANDARD
E
LECTRICAL
The following procedures are intended to aid the service technician to logically resolve operational issues
with the mechanical and standard electronics installations.
In the charts below, YES is a positive response to the test; NO is a negative response.
D01 T
HE
A
WNING
O
PERATES
I
N
R
EVERSE
O
F
T
HE
S
WITCH
P
LATE
This condition generally occurs during new installations or when major components have been replaced.
A
Confirm Switch is mounted in correct position and correctly
oriented.
YES
Switch mounted OK; go to test B
NO
Carefully remove the switch, rotate
180 and reinstall in panel. Reconnect
harnesses and retest
B
Confirm switch is wired correctly. Use the wiring diagram and
confirm the wires to/from the switch to the connector are
correctly placed.
YES
Switch wired OK; go to test C
NO
Rewire the switch according to the
wiring diagram
D02 T
HE
A
WNING
D
OES
N
OT
E
XTEND
A
ND
/O
R
R
ETRACT
For Multiple Switch configurations, the Power switch must be ON.
A
Check Installation Integrity
Use the wiring diagram and confirm that the components and
wiring are properly installed and connected
YES
Go to test B
NO
Correct as required
B
Confirm Power Supply
Is vehicle battery or power source providing 10V to 14V to the
Switch (Power switch for Multiple switch installations) For
battery installations, use test procedure “CT03 Testing the
Battery” on page 20.
YES
Go to test B
NO
Correct as required
C
Test Motor Function
1. For installations with an external plug; Disconnect plug.
2. For installations with a single switch; Remove switch plate and
disconnect the motor wires from the switch.
3. For installations with multiple switches, disconnect the
connector from the relay to the motor. If no connector, remove
the butt splices on the red and black wires from the motor. Cap
the wires to prevent shorting
4. Attach jumper leads to the emergency terminals located
on the back of the motor head.
5. Connect the other ends of the jumpers to a 12-18VDC
power source (i.e. drill battery). It may be necessary to try
then reverse the leads on the battery and try again.
6. Does the motor run?
YES
Motor is good, go to test C
NO
Motor is defective - replace
D
Test wire continuity between motor and wire ends.
YES
Wire continuity good – reconnect the
wires disconnected in the previous
test then go to test E
NO
Repair as required then reconnect
the wires disconnected in the
previous test.
DO2 continued on next page
Summary of Contents for ECLIPSE 2015