Carefree of Colorado Service
Manual
E
CLIPSE
052547-301r10
7
Tip: When the nut is removed, the bolt will slide out of the arm mounting block inside the arm channel.
Placing tape on the head of the mounting bolt and the spacers will prevent them from falling out when
the nut and motor are removed.
10. Remove the motor assembly. The motor assembly consists of the motor, mounting frame, gears, shaft
and roller end cap.
11. Place the new motor assembly in position over the mounting bolt.
Ensure that the spacer-washers
are all accounted for.
12. Secure using the washer and lock nut removed previously.
The nut should be tightened until snug
but the motor head should be able to swivel by hand.
13. Attach the rear cover to the motor assembly using the large screw removed previously.
14. Attach the motor and cable wires to the terminals inside the rear cover.
15. Align the roll bar with the end cap on the motorized arm assembly.
Rotate the end cap until the slot
in the cap aligns with the empty slot in the roller assembly, and then press the roller assembly fully into
the cap. The end cap must seat squarely over the end of the roller assembly when complete.
NOTE:
On early units, a spider gear inside the end cap is used to hold the roller tube in position with
the drive shaft. The replacement end cap no longer requires the use of the spider.
16. Secure the end cap to the roller assembly using two #10 x 5/8 square-drive screws.
17. Restore power and test operation.
If the awning moves in the wrong direction (i.e. extends when
retract is pushed) reverse only the two motor wires in the rear cover.
18. Attach the front cover using the small screws removed previously.