CareCo DL08146 Usage And Maintenance Instructions Download Page 2

www.careco.co.uk

CareCo, Hubert Road, Brentwood, Essex, CM14 4JE

2

Digi Blood Pressure Monitor - 

DL08146

Description

Arm type automatic blood pressure monitor

Display

LCD digital display

Measuring Principle

Oscillometric method

Measuring Localization

Upper Arm

Measurement Range

Pressure

0-299 mmHg (0-39.9kPa)

Pulse

40-199 pulses/min

Accuracy

Pressure

±3mmHg (±0.4kPa)

Pulse

±5% of reading

LCD Indication

Pressure

3 digits display of mmHg

Pulse

3 digits display

Symbol

Memory/Heartbeat/Low battery

Memory Function

2*120 sets memory of measurement values

Power Source

4pcs AA alkaline battery DC. 6V or AC adapter

Automatic Power Off

In 3 minutes

Main Unit Weight

Approx. 415g (batteries included)

Main Unit Size

L 130mm x W108mm x H56mm

Main Unit Lifetime

5 years under normal use

Battery Life

Could be used for 300 times for normal condition

Accessories

Cuff. instruction manual

Operating Environment

Temperature

5°C-40°C

Humidity

15%-85%RH

Air pressure

86kPa-106kPa

Storage Environment

Temperature -20°C-55°C . Humidity : 10%-85% avoid crash, sun 

burn or rain during transportation.

Specification

Summary of Contents for DL08146

Page 1: ...the measurement time prolonging the cuff s usage lifetime 2 120 sets memory function each measurement result will be displayed on the screen and automatically stored This unit has blood classification...

Page 2: ...igits display Symbol Memory Heartbeat Low battery Memory Function 2 120 sets memory of measurement values Power Source 4pcs AA alkaline battery DC 6V or AC adapter Automatic Power Off In 3 minutes Mai...

Page 3: ...identifies hazards that may cause minor personal injury product damage or property damage Type BF applied part Specifies serial number CE Mark conforms to essential requirements of the Medical Device...

Page 4: ...s Do not use a mobile phone near the unit This may result in operational failure Do not use the equipment where flammable gas such as anaesthetic gas oxygen or hydrogen or flammable liquid such as alc...

Page 5: ...denly Wrap the cuff properly Remeasure the correct way E 2 External strong disturbance When near a mobile phone or other high radiant the measurement will fail Keep quiet whilst in use E 3 Error appea...

Page 6: ...the device as picture Only provided cuff can be used can not change to any other branded cuff Irregular Heart Beat Systolic Blood Pressure Unit Diastolic Blood Pressure Pulse Rate Low Battery Symbol...

Page 7: ...ries into the compartment and ensure is battery is facing in the correct direction If the battery is low the symbol will appear Replenish the batteries with new ones in order to continue using the dev...

Page 8: ...ct that local laws take priority over the above mentioned requirements If in doubt consult your local representative or the technical service department 2 When using AC power to avoid possible damage...

Page 9: ...meantime the systolic diastolic and pulse rate will appear on the display 5 The measurement readings remain on the display until you switch off the device If no button is pressed for a period of 3 mi...

Page 10: ...of the cuff and close the cuff by affixing the velcro 5 The cuff should be snug on your upper arm so that you can fit 2 fingers between the cuff and your upper arm Any piece of clothing that restrict...

Page 11: ...ng on month the digit will increase 1 when press button each time you can choose from 1 to 12 Press button to confirm the month then it will set the date Same as the month setting each time you press...

Page 12: ...e measurement arm during measurement Use a cushion for support if necessary If the arm artery lies lower or higher than the heart a false reading will be obtained Only use clinically approved cuffs A...

Reviews: