A-1 INSTALLATION A-1
TECHNICAL SPECIFICATIONS
-
max. rated Output Amps @% Duty Cycle (Based on a 10 minute cycle) (Example; 250A@35% for DC Stick
and 320A@35% for AC/DC Balance TIG)
MODEL Digi-Tig320ACDC
Voltage
3 xAC208V or 480V 50/60Hz
INPUT
Fuse rating
31A/13A
No-load Voltage
70V
current Adjusting Range
20~250A
Rated Output Current
250A
DC
MMA
Rated Duty Cycle
35%
No-load Voltage
70V
Current Adjusting Range
10~320A
SP % (AC balance)
10~90
AC Square Wave Frequency
30~250Hz
AC
TIG
Rated Duty Cycle
35%
Current Adjusting Range
5~320A
DC
TIG
Rated Duty Cycle
35%
Peak Current
5~320A
Base/peak Current ratio
5~95%
Rated Duty Cycle
35%
Pulse width
5%~95%
Standard
PULSE
TIG
pulse Freq.
0.1~500Hz@DC
0.1~250Hz@AC
Current UP/Down-slope Time
0~10S
Initial current/weldingcurrent
5~150%
crater-fill current/welding current
5~95%
Pre gas Flow Time
0~25s
Post gas Flow Time
0~25s
Arc starting Mode
HF/LIFT TIG
Efficiency
≥
80%
Mass 28kg
Protection Class of enclosure
IP21S
Outline Dimensions mm
3
430x200x290