B-6 OPERATION B-6
25.HF/Lift TIG slector
Select between a lift start or High Frequency (HF) start.
HF start is ideal for both AC and DC starts. HF start
allows the arc to be start-ed without contacting the metal.
Simply place the tungsten above the metal about 1/8” or
less, and press the torch switch or foot pedal and the
arc will start momentarily, after a brief gas flow period.
HF can cause interference with other electronic devices.
Lift start is an alternative method of starting an arc
where HF is problematic. Do not use this method
with AC because contamination of the tungsten will occur
unless the arc is struck on a copper strip first and the arc
transferred to the weld area. Lift start is accomplished
by touching the metal with the tung-sten and then
quickly lifting the tungsten when the torch switch or foot
pedal is pressed. If done properly, an arc will be drawn.
Note: This is not the scratch start method where the
tungsten is rubbed across the surface of the metal to
draw an arc.
nameplate
T
he data plate stamped on the metal structure
complies with the EN 60974-1,
EN50199(EN60974-10) international standards and
contains the following information:
* (a) Manufacturer's name and address
* (b) Trademark
* (c) Model
* (No) Serial number
* ( ) The welding power
source comprises a frequency converter followed by
an transformer and rectifier that transforms input
voltage into direct current.
* (EN 60974-1/EN 50199) Standards applied.
* ( ) Direct current.
* (x) Utilisation factor expressed as a percentage of
useful work over a cycle of 10 minutes at an
ambient temperature of 40
o
C.
* (I
2
) Rated weld current.
* (U
2
) Conventional load voltage.
* (Uo) Rated no-load voltage.
* ( ) TIG welding.
* ( ) MMA welding.
* ( )) 1input phases.
* (IP21S) Casing protection degree in compliance
with the EN 60529 Standard:
IP2XX Casing protected against access to
dangerous components with fingers and against the
introduction of foreign matters with diameter 12.5
mm.
IPX3X Casing protected against rain failing at
60~on the vertical line.
IPXXC Casing protected against contact of a test
gauge
φ
2.5 mm length 100 mm with live
dangerous parts,
* (U
1
) Rated power supply voltage.
* (50/60 Hz) Power supply rated frequency.
* (l
lmax
) Maximum supply current.
(I
1 eff
) Effective supply current.* ( S ) Generator
suitable for installation in places where major risks
of electric shocks are preset
* (CE) In compliance with the European regulations
in force.
~
1~
f1
f2
~
Summary of Contents for Digi-Tig320ACDC
Page 27: ...B 13 OPERATION B 13...
Page 28: ...B 14 OPERATION B 14...
Page 29: ...B 15 OPERATION B 15...