3.4 Connection
of
electrical supply
The CTR9 requires the following voltage/frequency combination:
208 V -5 % +10%, 50-60 Hz, 3-phase
230 V -5 % +10%, 50-60 Hz, 3-phase
400 V -5 % +10%, 50-60 Hz, 3-phase
460 V -5 % +10%, 50-60 Hz, 3-phase
The required voltage and frequency is preset upon leaving the manufacturer.
Note:
Make sure that the supplied voltage and frequency are the same as
shown on the welder. The actual voltage and frequency is stated on the name
plate (see section 1.3 "Marking").
This machine must only be connected to a TN earthing system. The supply
must also be protected with a fuse as follows:
The 208 V supply requires a 60 Amp slow blow fuse Type K
or equivalent.
The 230 V supply requires a 63 Amp slow blow fuse
(Circuit braker Type D).
The 400 V supply require a 32 Amp slow blow fuse
(Circuit breaker Type D).
The 460 V supply requires a 30 Amp slow blow fuse Type K
or equivalent.
Mains electric supply