Version 08.04.2021
HW CAM(V31)/(V22)
CI-RL2-RLINK
P
a
g
e
11
2.4.2.
R-Link with 60pin Flex cable
Remove the Ribbon cable between the monitor’s monitor panel and the monitor PCB.
Connect the daughter PCB’s ribbon cable
CAR-IN
to the ribbon cable base of the main PCB.
For this procedure you may either use the original ribbon cable or the ribbon cable of
daughter PCB. Make sure that the connector pins of each pin connector are faced to the
platinum before clipping them.
Connect the daughter PCB’s ribbon cable
PNL OUT
to the ribbon cable base of
the
monitor panel’s short original Flex cable, by using the enclosed Ribbon cable
merger (pay same attention to platinum faced installation of the connector
pins!).
Carefully fix the daughter PCB to the monitor part by using the
enclosed longer screws and plastic spacers.
Attention:
The plastic washers must be installed
under the PCB, otherwise the length of the screws
may cause destruction inside the monitor
!
The picture on the right side shows the position for
leading out the out the ribbon cables
Note:
Please observe above warning notes for ribbon
cable installation!