15
Fig.25
c. How to replace the the condenser fan(noted: there are different structure and the fan installing position, but almost
the same installation methods).
Please see as below.
1>. Remove the spring
(
A
)
, and remove the compressor electrical cover
(
B
)
(Fig.26)
.
2>. Remove the two terminal of the fan electrical code(C, D) , mark them before removement to avoid mistake(noted:
the diagram below take ZEL compressor as a sample). In fact, different manufacturer
’
s compressor connection is
different, and mark it before unpluging the connection.
(Fig.26).
3). Remove the two screw
(
1
,
2
)
of the fans with the
Phillips head screwdrivers
, and remove the condenser fan(in
different model the fan installing position are different,but the replace methods almost same).
(Fig.26)
4) Remove the 4 fixing screw of the fans with the
Phillips head screwdrivers
(
3
,
4
,
5
,
6
)
, replace the fan
(Fig.26.1)
.
Fig.26 Fig.26.1
○
Refrigerant jet noise
Default: If here is intermittent noise like a water spray from the capillary.
Reason: The end of the capillary in the evaporator is in the wrong position, or there are rough edges on the
end of the capillary
Resolvent:
1>. Heat the soldered joint of the capillary
(
“
A
”
of Fig.19)
, then remove the capillary from the evaporator
and smooth the end with an eraser. (Caution: do not allow any particles into capillary unit)
2>. Replace the capillary into the evaporator, then solder it back into the correct position (not exceeding
15mm in the evaporator) and pack the joint with anti vibration compound
3>. Recharge with refrigerant. See
(Page3)